    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Chlorophenols in water ; Preconcentration ; Post-column photochemical dechlorination ; Electrochemical, UV and fluorescence detection ; Column switching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A specific HPLC method has been developed for the trace analysis of lower chlorinated aromatic compounds. The method consists of an on-line preconcentration and a post-column reaction step. On-line preconcentration of mono- and dichlorophenols from aqueous samples has been performed using PRP1, a divinylbenzene-styrene copolymeric sorbent as packing material for both pre-and analytical column. Enrichment factors of over 300 were obtained compared to regular (100 μl) loop injections, even for the highly polar monochlorophenols. After reversed-phase separation, post-column photochemical dechlorination is carried out directly in the eluent stream, using a photochemical reactor. Upon dechlorination, fluorescent products are formed, which can be detected selectively. The resulting fluorescence signal shows a linear response to the quantity of solute present over 2 to 3 orders of magnitude (correlation coefficients: 0.990–0.98). For the mono- and dichlorophenols, the detection limit of the photoconversion method is in the lower nanogram range. The method is especially suitable for the analysis of complex matrices such as effluent water samples or biological fluids containing traces of the polar chloroaromatic compounds together with large amounts of other constituents, which interfere when using more general methods of detection like UV absorption. The potential of this technique for automation has been demonstrated by using a microprocessor-controlled column switching unit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Miniaturized HPLC ; Post-Column Extraction Detection ; Segmented-Flow Open-Tubular Reactors ; Membrane Phase Separator ; Anti-Cancer Drugs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract An on-line, post-column, extraction system suitable for use with miniaturized HPLC (0.7–1 mm i.d. columns) is described. The system consists of a 30° angle segmenting tee, a PTFE extraction coil of variable length and a membrane phase separator. The internal volume of the phase separator is less than 1 μl. The total variance contribution of the system is between 1 and 6 sec2. The determination of the anti-cancer drugs VP 16 and VM 26 in urine by means of reversed-phase HPLC and fluorescence detection, using both on-column preconcentration and the present miniaturized post-column extraction system is presented as an application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Coupled LC-GC ; Retention gap ; LC trace enrichment ; Aqueous samples ; Organic pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m retention gap coupled to the capillary GC column served as the recipient of a relatively large sample volume (ca. 100 μl) introduced into the GC. Partially concurrent solvent evaporation during sample introduction allowed a large sample capacity. Recoveries of more than 95% were observed for the majority of the compounds studied. Using 1.0 ml aqueous samples, detection limits of less than 1 ppt were found. The applicability of the developed method was demonstrated for a river water sample.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.