Library

You have 0 saved results.
Mark results and click the "Add To Watchlist" link in order to add them to this list.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • Anti-Cancer Drugs  (1)
  • Aqueous samples  (1)
  • 1
    ISSN: 1612-1112
    Keywords: Miniaturized HPLC ; Post-Column Extraction Detection ; Segmented-Flow Open-Tubular Reactors ; Membrane Phase Separator ; Anti-Cancer Drugs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract An on-line, post-column, extraction system suitable for use with miniaturized HPLC (0.7–1 mm i.d. columns) is described. The system consists of a 30° angle segmenting tee, a PTFE extraction coil of variable length and a membrane phase separator. The internal volume of the phase separator is less than 1 μl. The total variance contribution of the system is between 1 and 6 sec2. The determination of the anti-cancer drugs VP 16 and VM 26 in urine by means of reversed-phase HPLC and fluorescence detection, using both on-column preconcentration and the present miniaturized post-column extraction system is presented as an application.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0935-6304
    Keywords: Coupled LC-GC ; Retention gap ; LC trace enrichment ; Aqueous samples ; Organic pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Trace enrichment for the GC analysis of a series of chlorinated pesticides and polychlorinated biphenyls (PCBs) in aqueous samples has been achieved through a simple on-line technique involving sorption on an LC micro-precolumn followed by direct elution into a gas chromatograph with hexane. A 5-m retention gap coupled to the capillary GC column served as the recipient of a relatively large sample volume (ca. 100 μl) introduced into the GC. Partially concurrent solvent evaporation during sample introduction allowed a large sample capacity. Recoveries of more than 95% were observed for the majority of the compounds studied. Using 1.0 ml aqueous samples, detection limits of less than 1 ppt were found. The applicability of the developed method was demonstrated for a river water sample.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...