Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel: DFG Deutsche Nationallizenzen  (3)
  • Key words Spine  (2)
  • Cervical spine  (1)
Datenquelle
  • Artikel: DFG Deutsche Nationallizenzen  (3)
Materialart
Erscheinungszeitraum
  • 1
    ISSN: 1432-0932
    Schlagwort(e): Key words Spine ; Interbody ; Fusion ; Compression ; Biomechanics ; Implant ; Posterior ; lumbar intervertebral fusion
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European spine journal 9 (2000), S. S057 
    ISSN: 1432-0932
    Schlagwort(e): Key words Image-guided spine ¶surgery ; Computer navigation ; Cervical spine ; Thoracic spine ; Lumbar spine ; Iliosacral joint ; Pedicle screws
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Computer assistance has been shown to improve significantly the accuracy and safety of pedicle screw insertion under clinical conditions. The technique of image-guided navigation is described in this article, based on the authors’ clinical experience of over 4 years. The value of navigation systems for preoperative planning is discussed. Clinical results of the application of this new method in the cervical, thoracic, and lumbosacral spine as well as the iliosacral joints are presented by means of the authors’ own studies and reports from the literature. Pros and cons of computer guidance are discussed. The authors predict computer navigation will be used in percutaneous and minimally invasive procedures in the near future.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1432-0932
    Schlagwort(e): Key words Spine ; Implant ; Pedicle screws ; Navigation ; Fluoroscopy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A new computer-based navigation system for spinal surgery has been designed. This was achieved by combining intraoperative fluoroscopy-based imaging using conventional C-arm technology with freehand surgical navigation principles. Modules were developed to automate digital X-ray image registration. This is in contrast to existing computed tomography- (CT) based spinal navigation systems, which require a vertebra-based registration procedure. Cross-referencing of the image intensifier with the surgical object allows the real-time image-interactive navigation of surgical tools based on one single registered X-ray image, with no further image updates. Furthermore, the system allows the acquisition and real-time use of multiple registered images, which provides an advanced multi-directional control (pseudo 3D) during surgical action. Stereotactic instruments and graphical user interfaces for image-interactive transpedicular screw insertion have been developed. A detailed validation of the system was performed in the laboratory setting and throughout an early clinical trial including eight patients in two spine centers. Based on the resulting data, the new technique promises improved accuracy and safety in open and percutaneous spinal surgery.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...