Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (6)
  • 2000-2004
  • 1995-1999  (6)
  • 1998  (6)
Material
  • Electronic Resource  (6)
Years
  • 2000-2004
  • 1995-1999  (6)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 18-24 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An in-vacuum minipole (short period) insertion device has been developed in a collaboration between SPring-8 and the National Synchrotron Light Source (NSLS). The magnetic arrays were assembled, field measured, corrected, and vacuum tested by SPring-8 and were installed in an NSLS-developed chamber with mechanical parts in the NSLS X-Ray Ring (E=2.584 GeV) in May 1997 and a successful commissioning of the device was carried out in June 1997. The device is made of permanent magnets with 30.5 periods and a period length of 11 mm. It is designed to produce fundamental radiation at 4.6 keV, and with a modest value of deflection parameter (K=0.7 at 3.3& mm gap) enables higher harmonics to be used as well, for a variety of experiments. A detailed description of the mechanical support and vacuum chamber will be reported elsewhere. We describe technical challenges encountered in constructing this type of device, and present an outline of our collaboration. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 426-427 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: There are several ways of producing circularly polarized light, such as using asymmetric devices, crossed undulators etc. The SPring-8 helical undulator introduces a simple way of producing both horizontal and vertical fields in one undulator. All the magnet arrays are arranged above and below the plane of the electron orbit, so there is no limitation of access from the sides of the undulator. For the SPring-8 BL25SU, two helical undulators will be installed in tandem, and the helicity of the polarization can be switched at up to 10 Hz using five kicker magnets.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 403-405 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Most of the SPring-8 insertion devices are in-vacuum undulators except for the soft X-ray devices and one elliptical wiggler. The standard-type SPring-8 in-vacuum undulator has a period of 32 mm and a minimum gap of 8 mm. The fundamental radiation energy ranges from 5.2 to 18.5 keV. Three standard in-vacuum undulators are already installed in the ring and are operating without any problems. The magnetic field correction, the vacuum system and the commissioning of the in-vacuum undulators are described in this paper.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 406-408 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Before the commissioning of SPring-8, the in-vacuum hybrid undulator developed at SPring-8 had been brought to the ESRF for the first beam test in the summer of 1996. The purpose of this test was to investigate the influence of the in-vacuum undulator on the beam and check its vacuum system. However, heating by the resistive wall impedance turned out to be a critical issue for the in-vacuum undulators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 417-419 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm period) developed at SPring-8, while the requisite vacuum chamber and mechanical systems were developed at the NSLS. At a magnet gap of 3.3 mm, IVUN produces 4.6 keV radiation in the fundamental, with useful photon fluxes in both the second and third harmonics. The magnet gap is adjustable between 2 and 10 mm. A brief overview of IVUN is presented, together with initial commissioning results: the dependence of electron-beam lifetime and bremsstrahlung on magnet gap, and the output radiation spectrum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 475-477 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Measurement of integrated magnetic induction is an important part of the construction of insertion devices. The so-called `flipping coil system' is normally utilized to characterize the integrated multipole components of the device, a requirement which varies from one storage ring to another. A Helmholtz coil system is used to determine a magnetization vector of each magnet piece in the device. Both systems are designed to measure the integrated magnetic flux to deduce the necessary quantities using the known relationship. We have developed an unconventional system which has a continuously rotating mechanism that allows the use of a lock-in amplifier instead of an integrator or a voltmeter. Detailed descriptions of the equipment are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...