Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the precise low background experiments on β decay and material sciences, we are planning to build a new ISOL-type facility to accelerate various β-radioactive nuclei utilizing the existing 5 MV Van de Graaff accelerator and an RFQ linac. Present status of the designing work is reported. In the present work, optical elements of the 41-m-long beam transport line to connect Van de Graaff accelerator and an RFQ linac were designed. Using two dipole magnets, two electric quadrupole doublets and six electric quadrupole triplets, low energy radioactive nuclear beams can be transported with sufficient efficiency. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 64 (1988), S. 496-499 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Some degradation modes of 1.3 and 1.55 μm buried heterostructure distributed feedback (DFB) lasers grown by liquid-phase epitaxy are clarified. A degradation mode induced by the inhomogeneous optical-field distribution along the laser cavity is found to exist in DFB lasers. In most DFB lasers, the interface degradation between first growth-step (double heterostructure) layers and second growth-step (burying) layers occurs in the same manner as Fabry–Perot lasers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 51-55 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have developed a time pickup system for monitoring the beam bursts from a cyclotron. The time pickup can measure the phase and the width of the beam bursts by detecting secondary electrons emitted from a foil or a wire target inserted into the beam with time resolutions around 200 ps full width at half maximum in spite of its simple structure. By using the foil and the wire targets appropriately, monitoring the bursts of a variety of beams can be achieved. In addition, by adjusting the position of the target, a high enough detection rate of the beam burst is obtained with a minimum of interference with the beam. The present investigation shows that it is needed to adjust the collection voltage of the time pickup because the optimum collection voltages for high resolution measurement are in the range from −0.5 to −1.0 kV and those for high efficiency measurement are not less than −4.0 kV. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 66 (1989), S. 881-884 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Carbonaceous films with high conductivity have been prepared by a pyrolytic chemical-vapor-deposition method using hydrocarbons containing oxygen atoms, phenols, carboxylic acids, etc. The films obtained are self-supporting and flexible. The electrical conductivities of the films depend on the pyrolyzing temperature but not remarkably on the kind of raw materials. The films are converted to high-quality graphitized films with conductivity of 1.6×104 S/cm by heating under an Ar atmosphere to 2800 °C. The electrical conductivity and thermoelectric power of the films are examined as a function of the heat-treatment temperatures. The excellent property of the films obtained in this study seems to arise from the effect of oxygen atoms in the process of condensed aromatic ring formation by pyrolysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 30 (2003), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  We report here on a patient with bilateral cleft lip and palate (BCLP) and a missing premaxilla, who underwent dentoalveolar reconstruction of the cleft and premaxillary alveolus using endosteal implants after bone grafting. The patient, whose maxillary incisors and premaxilla were missing, had corticocancellous bone grafting from the iliac crest, followed by excellent bone formation at the anterior alveolus. After the placement of the endosteal implants and the completion of the pre-surgical orthodontic alignment, orthognathic surgery was performed for the restoration of a Class III open bite. After post-operative orthodontic preparation, the final fixed prostheses were completed. This treatment procedure offers an option of dentoalveolar reconstruction for BCLP patients with an excised premaxilla.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We describe the use of endosseous implants in the autogenous particulate cancellous bone and marrow grafted alveoli after orthognathic surgery for dental rehabilitation of patients with cleft lip and palate. This procedure has been applied to two patients and produced good results functionally and aesthetically. The results are encouraging and indicate that implant placement after orthognathic surgery is useful for patients both with congenital missing teeth and retrognathic maxillae.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 519 (1987), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1437-1596
    Keywords: Serum groups, immunoblotting ; α2HS-glycoprotein typing ; Bloodstains, immunoblotting ; Serumgruppen, Immunoblottierung ; α2HS-Glykoprotein, Typisierung ; Blutspuren, Immunoblottierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Seren und Blutextrakte wurden auf Polyacrylamidgelen isoelektrisch fokussiert. Die fokussierten Proteine wurden auf Nitrozellulosemembranen durch Diffusion oder elektrophoretisch transferiert. Durch ein spezifisches Antiserum erfolgte auf den Membranen die AG-AK-Reaktion. Nach Waschen der Membranen wurde der gebundene Antikörper mit einem enzymisch markierten Anti-Kaninchen IgG-Antikörper nachgewiesen. Mit dieser Technik konnten die gruppenspezifische Komponente, das α2HS-Glykoprotein, die Komplementkomponenten C6 und C7, der Gerinnungsfaktor 13B und das Plasminogen sehr empfindlich phänotypisiert werden. Vorzugsweise konnten bis zu 6 Monate alte Blutspuren richtig typisiert werden.
    Notes: Summary Sera and bloodstain extracts were subjected to isoelectric focusing in polyacrylamide gels. The focused proteins were transferred to nitrocellulose membranes by diffusion or electrophoretically, then allowed to react with specific antiserum and, after washing, with peroxidase-labeled anti-rabbit IgG. The immune complexes formed on the membranes were detected with 4-chloro-1-naphthol and hydrogen peroxide. Serum group-specific component, α2HS-glycoprotein, the sixth and the seventh component of complement, factor 13B, and plasminogen could be phenotyped with high sensitivity. Bloodstains as old as 6 months could be correctly typed for α2HS-glycoprotein by the blotting technique.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 99 (1987), S. 135-142 
    ISSN: 1437-1596
    Keywords: Simultaneous phenotyping, genetic markers ; Isoelectric focusing, electrophoresis ; Immunoblotting, paternity testing ; Phänotypisierung genetischer Marker ; Vaterschaftsbegutachtung, kostensparende Methoden und Dokumentation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Description / Table of Contents: Zusammenfassung Es werden zeit- und kostensparende Methoden für die Vaterschaftsbegutachtung beschrieben. Siebzehn genetische Systeme werden in sechs Gruppen unterteilt. 1. Gruppe: Transferrin (Tf), Faktor B (BF) und Phosphoglucomutase 1 (PGM1); 2. Gruppe: Gc-System (Gc) oder α1-Antitrypsin (PI) und α-2HS-Glycoprotein (HSGA); 3. Gruppe: Komplement-Komponente C6 und C7, Faktor 13B (F13B) und Plasminogen (PLG); 4. Gruppe: Haptoglobin (Hp), C8 α-γ Kette (C81) und Faktor I (IF); 5. Gruppe: saure Erythrozyten-Phosphatase (ACP), Esterase D (ESD), Glutamat-Pyruvat-Transaminase (GPT); 6. Gruppe: 6-Phosphogluconat Dehydrogenase (PGD) und Glyoxalase I (GLO). Jede Gruppe wurde gleichzeitig mittels Elektrophorese oder isoelektrische Fokussierung (IEF) mit Färbung oder Immunoblotting untersucht. Diese Methoden erwiesen sich in der Praxis als zeit- und kostensparend und erleichtern die vorübergehende Aufbewahrung und Dokumentation der Elektrophorese-Bilder.
    Notes: Summary Time- and cost-saving methods for paternity testing are described. Seventeen genetic systems were divided into six groups: (1) transferrin (Tf), factor B (Bf), and phosphoglucomutase 1 (PGM1); (2) group-specific component (Gc) or α1-antitrypsin (PI) and α2HS-glycoprotein (HSGA); (3) complement components C6 and C7, factor 13B (F13B), and plasminogen (PLG); (4) haptoglobin (Hp), C8 α-γ chain (C81), and factor I (IF); (5) red cell acid phosphatase (ACP), esterase D (ESD), and glutamic-pyruvic transaminase (GPT); and (6) 6-phosphogluconate dehydrogenase (PGD) and glyoxalase I (GLO). Each group of systems was typed simultaneously by electrophoresis or isoelectric focusing (IEF) followed by staining or immunoblotting. These methods are very practical because they afford a considerable saving of time, work and expense, and facilitate semipermanent preservation of electrophoretic patterns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Archives of gynecology and obstetrics 243 (1988), S. 221-224 
    ISSN: 1432-0711
    Keywords: Vaginal delivery ; Caesarean section ; Previous caesarean section scar ; Ultrasonography ; Lower uterine segment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We examined 84 lower segment caesarean section scars by ultrasonography near term. Seventy scars showed good healing with a thickness of the lower uterine segment of more than 3 mm; 14 scars showed poor healing with a thickness of less than 2 mm and loss of continuity. Among 70 patients with good healing, 24 patients delivered vaginally but the remaining 46 patients have had repeat caesarean sections for other obstetric indications. Intraoperative findings in these 46 patients were as follows: Grade I (no thinning of the lower uterine segment), 42; Grade II (thinning and loss of continuity of the lower uterine segment but fetal hair not visible), 4; Grade III (thinning of the lower uterine segment and fetal hair visible), 0. Fourteen patients with poor healing had repeat caesarean sections. Intraoperative findings in these 14 patients were as follows: Grade I, 0; Grade II, 9; Grade III, 5. These results indicate that ultrasound examination detect thinning of the lower uterine segment and may help to determine management.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...