Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (3)
  • 1995-1999  (3)
  • Angst  (1)
  • Chemistry  (1)
  • Elektronisches Hörimplantat  (1)
  • General Chemistry
Material
  • Electronic Resource  (3)
Year
  • 1
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schwerhörigkeit ; Implantierbare Hörgeräte ; Elektronisches Hörimplantat ; TICA ; Key words Sensorineural hearing loss ; Implantable hearing aid ; Electronic hearing implant ; TICA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Recently, Zenner et al. implanted the first totally implantable electronic hearing devices in patients with SNHL (HNO 46 [1998] 844–852). In the present report, technical and audiological features of the implant TICA are published. The development of the piezoelectric transducer and the microphone for implantation in the posterior wall of the auditory canal as components for the present fully implantable hearing system has already been described (HNO 45, 1997, 792–880). Here we report about our experience with the electronic main module that completes the TICA LZ 3001 system. This module is suited for implantation in the mastoid bone and contains the signal-processing electronics and an integrated battery that can be recharged transcutaneously with a portable charger. The recharging time is around 2 h for an implant operating time of 50h. The microphone and transducer connectors allow for easy replacement of the main module when the battery lifetime is reached. This lifetime is around 3–5 years. A small wireless remote control allows volume adjustment, contains an on/off switch, and permits selection of four different individual hearing programs. The basic audiological features are provided by a flexible, digitally programmable 3-channel-AGC-system with a peak clipping function. The total bandwidth is around 10 kHz. To our knowledge this is the first fully implantable hearing system that has been in implanted in humans.
    Notes: Zusammenfassung Kürzlich wurde über die Entwicklung eines elektromechanischen, piezoelektrischen Wandlers und eines Mikrofons zum subkutanen Einbau in die hintere Gehörgangswand als Komponenten eines zukünftigen vollständig implantierbaren Hörsystems für Innenohrschwerhörige berichtet (HNO 45, 1997, 792–880). Zwischenzeitlich konnte die Entwicklung eines elektronischen Hauptmoduls zur Implantation auf dem Planum mastoideum abgeschlossen werden, das diese Mikrofone und Wandler zu dem kompletten Hörimplantat TICA® LZ 3001 ergänzt. Dieses Hauptmodul enthält neben der signalverarbeitenden Elektronik eine spezielle Batterie, die transkutan mit einem portablen Ladegerät nachgeladen wird. Nach einer Volladung, die ca. 2 h benötigt, ist das Implantat für rund 50 h kontinuierlich betriebsbereit. Das Ladegerät wird ähnlich wie bei Mobiltelefonen in einer netzbetriebenen Station nachgeladen. Lösbare Steckverbindungen zu Mikrofon und Wandler ermöglichen den einfachen operativen Austausch des Hauptmoduls, wenn die Batterielebensdauer erreicht ist. Dies wird nach ca. 3–5 Jahren erwartet. Dem Patienten steht eine kleine, drahtlose Fernbedienung zur Verfügung, mit der Lautstärke, Ein/Aus sowie 4 Hörprogramme für unterschiedliche Hörsituationen eingestellt werden können. Die grundlegenden audiologischen Eigenschaften sind durch ein flexibel digital programmierbares 3-Kanal-AGC-System mit Peak-clipping-Funktion gegeben. Die gesamte Übertragungsbandbreite beträgt ca. 10 kHz. Das vollimplantierbare Hörsystem wurde im Rahmen der klinischen Erprobung Anfang Juni 1998 erstmals am Menschen angewendet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Droperidol ; Nebenwirkungen ; Angst ; Anspannung ; Befindlichkeit ; Postoperative Übelkeit und Erbrechen ; Key words Droperidol (side-effects) ; Anxiety ; Tension ; Overall mood ; Postoperative nausea and vomiting
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Background: Droperidol even in low doses such as 0,5 mg to 1,25 mg can increase postoperative anxiety and state of tension. The aim of this study was to determine whether these side effects occur frequently following low-dose droperidol and to see whether these are dose related. Methods: 184 female in- and outpatients ASA grade 1 and 2 undergoing gynaecological laparoscopy were recruited to this prospective, double-blind study. General anaesthesia was standardized (induction with thiopentone, fentanyl 2 µg/kg and vecuronium 0,1 mg/kg, tracheal intubation, maintainance with enflurane in N2O/O2). Patients were randomly allocated to receive saline (n=45), 0,625 mg (n=46), 1,25 mg (n=47) or 2,5 mg (n=46) droperidol i.v. 10 minutes before the end of surgery. 1, 3, 6, and 24 hours postoperatively, the patients’ anxiety, state of tension and overall mood was evaluated using two psychological questionnaires which had been tested for the perioperative period (Erlanger anxiety and tension-scale / BSKE-EWL-test). Sedation was evaluated by the staff of the recovery room. In addition, postoperative nausea and vomiting (PONV) was assessed using a 100 mm visual analogue scale and by counting the episodes of retching or vomiting. PONV was then rated over the whole observation period as none, mild, moderate or severe using a fixed scoring algorithm. Statistical analysis was performed using the ANOVA and the chi2-test. Results: The patients did not differ with regard to biometric data, duration of surgery and anaesthesia. The postoperative scores for anxiety, state of tension and overall mood were not different between the groups at any observation time (Fig. 1: anxiety and tension: P=0,5687; figure 2: overall mood: P=0,0647). Quality of sleep in the first night after surgery was the same in all groups (Table 2 and 3). Sedation was not significantly different (Table 4; P=0,0704). Furthermore, duration of stay in the recovery room did not differ (P=0,4353). On the other hand, three patients from the 2,5 mg droperidol group had to stay unexpectedly on the ward overnight, because they had been too much sedated to be discharged at home. This was not the case with any patient from the other groups. Compared to placebo, PONV over the whole 24 h observation period was significantly reduced by droperidol (Fig. 3; P=0,0338): completely free from PONV: placebo: 41,3%, 0,625 mg droperidol: 67,4%, 1,25 mg droperidol: 53,2%, 2,5 mg droperidol: 71,7%. Also the severity of PONV was reduced. Conclusion: In gynaecological laparoscopy under general anaesthesia with tracheal intubation, we recommend droperidol 0,625 mg in the prevention of PONV, as it reduces PONV as well as 2,5 mg with no severe sedation in this dosage. Psychological side effects did not occur more frequently after droperidol compared to placebo in any of the investigated dosages.
    Notes: Zusammenfassung In vorliegender Studie wurden das Ausmaß postoperativer Angst, innerer Anspannung und allgemeiner Befindlichkeitsstörungen nach intraoperativ verabreichtem Droperidol und eine mögliche Dosisabhängigkeit dieser Nebenwirkungen untersucht. Zu diesem Zweck wurden erstmals zwei evaluierte Selbstbeurteilungsfragebögen eingesetzt. 184 ASA I und II Patientinnen, die sich einer gynäkologischen Laparoskopie in standardisierter Intubationsnarkose unterzogen, wurden in diese randomisierte, doppelblinde und plazebokontrollierte Untersuchung aufgenommen. Zehn Minuten vor Narkoseende erhielten die Patientinnen i.v. Kochsalz, 0,625 mg, 1,25 mg oder 2,5 mg Droperidol. Angst und allgemeines Befinden sowie Übelkeit und Erbrechen in der postoperativen Phase (PONV) wurden 1, 3, 6 und 24 h postoperativ registriert. Die Werte für Angst und allgemeines Befinden zeigten zu keinem Untersuchungszeitpunkt Gruppenunterschiede. Die Schlafqualität in der ersten postoperativen Nacht war in allen Gruppen gleich. Verglichen mit Plazebo wurde PONV durch Droperidol in jeder Dosierung gesenkt (p=0,0338): komplett frei von PONV: Plazebo: 41,3%, Droperidol 0,625 mg: 67,4%, 1,25 mg: 53,2%, 2,5 mg: 71,7%. Bei gynäkologischen Laparoskopien in Intubationsnarkose empfehlen wir zur Prophylaxe von PONV 0,625 mg Droperidol, da es ebensogut antiemetisch wirksam ist wie 2,5 mg. Psychische Nebenwirkungen wie Angst oder andere Befindlichkeitsstörungen treten in keiner der untersuchten Droperidoldosierungen vermehrt auf.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 42 (1996), S. 1789-1792 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...