Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (1)
  • 1990-1994  (1)
Material
  • Electronic Resource  (1)
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 932-936 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Radiation damage of silicon detectors can be investigated by means of several techniques. In a high-luminosity environment the thermally stimulated current (TSC) spectroscopy proves to be a good experimental method in order to analyze the deep defects induced by irradiation. Two different experimental systems for TSC spectroscopy, developed at the Energy Engineering Department of Florence, are examined in detail. The two systems differ in the cryogenic agent used to cool the silicon detectors: the first one utilizes a helium-gas closed-cycle Gifford–McMahon two-stage cryogenerator; the second one utilizes the helium vapors present inside a liquid helium Dewar. In the two systems two different heating procedures are used in order to perform the thermal scans necessary to carry on the TSC measurements: in the former system an electric heater performs the thermal scan, while in the latter one the heating process is achieved utilizing the temperature variation of the helium vapors inside the Dewar as a function of the height over the surface of the boiling helium. The main advantage of the electric heater is the possibility of obtaining heating rates β as high as 2.0 K/s, while the helium vapors ensure an excellent temperature matching between the temperature sensor and the sample (with the drawback of lower heating rates). The two methods used to get information by means of TSC spectroscopy, (variation of β and delayed heating) are briefly described together with an evaluation of the sensitivity of the measurement (no difference has been made between the two systems because the use of a different cryogenic agent does not affect sensitivity). Both systems proved satisfactory, even if the ease of operation of the helium gas makes it preferable in the temperature range examined by our measurements (120–200 K).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...