Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 337 (1974), S. 849-849 
    ISSN: 1435-2451
    Keywords: Vascular Injury ; Arterial Reconstruction ; Traumatic Ischemia ; Gefäßverletzung ; Arterienrekonstruktion ; Traumatisch bedingteIschämie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bericht über 314 Eingriffe am Arteriensystem nach Unfällen, davon 35 Aortenverletzungen. Unfallursachen: penetrierende, iatrogene, stumpfe Verletzungen, Verkehrsunfälle. Therapie: primär 40 Ligaturen, 9 Amputationen, 19 mal konservative Behandlung. 246 Arterien warden rekonstruiert. Ergebnis: 183 Rekonstruktionen zeigen gute, 18 eingeschränkte Funktion, 24 Patienten warden amputiert, 31 starben. — 28 Ligaturen zeigen gute Funktion, 5 schlechte Funktion, 6 Patienten warden amputiert, 1 starb. — Die konservativ Behandelten zeigen 9 mal gute, 5 mal eingeschränkte Funktion, 1 Amputation und 3 mal letalen Ausgang.
    Notes: Summary The report deals with 314 vascular operations after accidents, 35 of which involved aortic injury. Etiology: penetrating, iatrogennc, traumatic, following traffic accidents. Treatment: primary ligations in 40, amputation in 9, conservative treatment in 19 patients. Arterial reconstruction was performed in 246 cases. Results: 183 reconstructions resulted in good, 18 in limited function, 24 patients needed amputation, and 31 died. Twenty-eight ligations left good and 5 bad function, 6 patients needed amputation, and 1 died. Of the conservatively treated patients, 9 had good, and 5 had limited function, 1 required amputation, and 3 died.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 4 (1994), S. 371-376 
    ISSN: 1432-1084
    Keywords: Contrast media ; Gastrointestinal tract ; Infants ; Iotrolan ; Radiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Over the past 5 years we have used the new dimeric, non-ionic, water-soluble contrast agent iotrolan (Isovist-300) in 370 studies of the paediatric gastrointestinal tract. Iotrolan is by far the best accepted and tolerated contrast agent for young children. Because of its iso-osmolality it can be used without dilution. No ill effects were reported in cases of aspiration or perforation. In all studies very high contrast images were obtained and the required diagnostic information was provided. The only disadvantage of iotrolan is its present high price. However, in view of the small volumes required in children (10 ml is sufficient in 59% and 20 ml sufficient in 92% of investigations) this should not be a major obstacle to its use. Iotrolan promotes a much greater readiness among paediatricians and paediatric surgeons to have gastrointestinal studies performed on very small and very sick babies.