Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1980-1984  (1)
  • 1970-1974  (1)
  • 1980  (1)
  • 1974  (1)
  • Polymer and Materials Science  (2)
Material
Years
  • 1980-1984  (1)
  • 1970-1974  (1)
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Materialwissenschaft und Werkstofftechnik 11 (1980), S. 244-258 
    ISSN: 0933-5137
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Behaviour of stainless cast alloys under combined mechanical and corrosive attackIn media with 3000 mg B/1 (as boric acid, H3BO3) and varying chloride contents down to 1 mg Cl-/1 13%-Cr-steels show pitting. Under constant load cracks appear simultaneously. As can be expected, 17%-Cr-steels are more resistant and duplex ferritic austenitic steels exhibit no corrosion cracking in 3% NaCl-solution even after 10 000 hrs. Generally, corrosion resistance improves with increasing contents of ferrite forming elements. Corrosion cracks are interpreted in termes of anodic stress corrosion cracking. Notch impact bending tests with hydrogen charged specimens show that deformability is reduced.
    Notes: 13%-Cr-Stähle zeigen in Lösungen mit 3000 mg B/1 (als Borsäure, H3BO3) und unterschiedlichen Chloridgehalten Lochkorrosion bis herab zu Konzentrationen von 1 mg Cl-/1. Bei mechanischer Zugbeanspruchung treten gleichzeitig Risse auf. 17%-Cr-Stähle sind erwartungsgemäß beständiger und ferritisch-austenitische Stähle zeigen in 3% NaCl-Lösung auch im 10 000 h-Versuch keine Korrosionsrisse. Generell steigt die Beständigkeit mit zunehmendem Anteil an ferritbildenden Elementen. Die Korrosionsrisse werden als anodische Spannungsrißkorrosion interpretiert. Kerbschlagbiegeversuche mit wasserstoffbeladenen Proben ergeben eine Abnahme des Verformungsvermögens.
    Additional Material: 21 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 25 (1974), S. 734-739 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The influence of imposed protection currents on the efficiency of inhibitors for cooling watersIn case where the cathodic protection of a cooling system is not feasible a combination of cathodic protection and inhibition may be of advantage. The authors have studied the potential influence of a direct current on the efficiency of an inhibitor; during the experimental work they have used a current intensity corresponding to the maximum intensity of the protection current used in practice. Using potentiokinetic methods they have found that the number of inhibitors which may be used in such conditions is rather small. In the case of inhibitors based on nitrites or amines the protecting efficiency is rather reduced after some hundred hours' operation under direct current, and in some case even a corrosion stimulation has been experienced. Inhibitors based on chromates and anticorrosion oil emulsions exhibit improved electrochemical stability, though, in the case of oils emulsion breaking must be taken into account after relatively short durations of operation.
    Notes: In Fällen, wo der kathodische Schutz eines Kühlsystems schwer durchführbar ist, erweist sich eine Kombination von kathodischem Schutz und Inhibierung als vorteilhaft. Die Verfasser untersuchten mögliche Einflüsse von Gleichstrom auf die Wirksamkeit von Inhibitoren; bei diesen Versuchen arbeiteten sie mit einer Stromstärke, welche der maximalen in der Praxis verwendeten Schutzstromstärke entsprach. Mit Hilfe von potentiokinetischen Methoden wurde gefunden, daß die zahl der unter diesen Bedingungen verwendbaren Inhibitoren sehr klein ist. Im Falle von Inhibitoren auf Basis von Nitriten oder Aminen verringert sich schon nach einigen Stunden Gleichstromeinwirkung die Schutzwirkung und in manchen Fällen zeigt sich sogar eine stimulierende Wirkung. Die Inhibitoren auf Basis von Chromaten oder Korrosionsschutzölemulsionen sind hingegen elektrochemisch gut beständig im Falle der Öle ist jedoch damit zu rechnen, daß die Emulsion schon nach verhältnismäßig kurzer Betriebsdauer bricht.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...