Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Electrochimica Acta 15 (1970), S. 147-159 
    ISSN: 0013-4686
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Computational Physics 81 (1989), S. 53-69 
    ISSN: 0021-9991
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Computer Science , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Journal of Computational Physics 74 (1988), S. 41-60 
    ISSN: 0021-9991
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Computer Science , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: We investigated the in vitro proliferation of peripheral blood mononuclear cells (PBMC) from Parietaria-allergic subjects, atopic patients with other sensitizations and healthy controls to Parietaria judaica pollen extracts. PBMC from almost all 44 subjects, divided into five groups (Parietaria-, grass-, Parietaria and grass-, Dermatophagoides-sensitive patients and normal individuals) were able to proliferate in response to the extract without statistically significant differences between groups. Mean values of the stimulation indexes for the five groups were respectively: 10.73, 3.18, 5.50, 10,56, 9.28. The results of separation experiments showed that the responding cells were T lymphocytes. Mitogenic effect of the Parietaria pollen extract was excluded by the absence of proliferative PBMC response from cord blood of seven newborns. These results indicate that Parietaria-sensitive, other atopics and normal individuals have Parietaria-specific T cells able to proliferate in vitro to Parietaria allergens.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 42 (1898), S. 15-38 
    ISSN: 1432-069X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 52 (1900), S. 163-184 
    ISSN: 1432-069X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 25 (1974), S. 734-739 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: The influence of imposed protection currents on the efficiency of inhibitors for cooling watersIn case where the cathodic protection of a cooling system is not feasible a combination of cathodic protection and inhibition may be of advantage. The authors have studied the potential influence of a direct current on the efficiency of an inhibitor; during the experimental work they have used a current intensity corresponding to the maximum intensity of the protection current used in practice. Using potentiokinetic methods they have found that the number of inhibitors which may be used in such conditions is rather small. In the case of inhibitors based on nitrites or amines the protecting efficiency is rather reduced after some hundred hours' operation under direct current, and in some case even a corrosion stimulation has been experienced. Inhibitors based on chromates and anticorrosion oil emulsions exhibit improved electrochemical stability, though, in the case of oils emulsion breaking must be taken into account after relatively short durations of operation.
    Notes: In Fällen, wo der kathodische Schutz eines Kühlsystems schwer durchführbar ist, erweist sich eine Kombination von kathodischem Schutz und Inhibierung als vorteilhaft. Die Verfasser untersuchten mögliche Einflüsse von Gleichstrom auf die Wirksamkeit von Inhibitoren; bei diesen Versuchen arbeiteten sie mit einer Stromstärke, welche der maximalen in der Praxis verwendeten Schutzstromstärke entsprach. Mit Hilfe von potentiokinetischen Methoden wurde gefunden, daß die zahl der unter diesen Bedingungen verwendbaren Inhibitoren sehr klein ist. Im Falle von Inhibitoren auf Basis von Nitriten oder Aminen verringert sich schon nach einigen Stunden Gleichstromeinwirkung die Schutzwirkung und in manchen Fällen zeigt sich sogar eine stimulierende Wirkung. Die Inhibitoren auf Basis von Chromaten oder Korrosionsschutzölemulsionen sind hingegen elektrochemisch gut beständig im Falle der Öle ist jedoch damit zu rechnen, daß die Emulsion schon nach verhältnismäßig kurzer Betriebsdauer bricht.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 29 (1978), S. 303-311 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Electrochemical behaviour of materials in sulfide containing mediaThe corrosion behaviour of metallic materials in waters containing hydrogen sulfide and considerable chloride amounts (130 g/l) depends on composition and structure of the materials (ferrous and nonferrous) as well as on the gas contents (in particular hydrogen) in the medium. Electrochemical measurements show that several materials exhibit to passivation ranges (-500 m V and -200 m V) the latter being characteristic of materials having better corrosion resistance.
    Notes: Das Korrosionsverhalten von metallischen Werkstoffen in Wasser mit Schwefelwasserstoff und höheren Chloridkonzentrationen (130 g/l) ist abhängig von Zusammensetzung und Gefüge der Werkstoffe (Eisen und Nichteisenmetalle) und vom Gasgehalt (besonders Wasserstoff) des Mediums. Elektrochemische Messungen zeigen, daß mehrere Werkstoffe zwei Passivitätsbereiche aufweisen (-500 m V und -200 m V), wobei der letzte Potentialbereich für die Werkstoffe charakteristisch ist, die höhere Korrosionsbeständigkeit besitzen.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 27 (1976), S. 425-431 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Testing and Selecting Cavitation InhibitorsAn investigation has been made into possibility of using electrochemical procedures as well as the gravimetrical method for testing cavitation inhibitors. The relation between the structure of the inhibitor, the nature and form of the cavitation attack and the mechanism of destruction was also examined. This work was performed with a group of conventional cooling water inhibitors and some pyridine compounds.It was shown that electrochemical investigations are less suitable for enabling inhibitors to be selected for high cavitation intensities, because electrochemical losses amount to only a relatively small part of the total loss of material. Nevertheless they are indispensable as a supplement to magnetostrictive investigations for appraising the overall performance of an inhibitor, because it has been found that a good cavitation inhibitor does not always achieve the same success against electrochemical corrosion.Furthermore it was demonstrated that interface inhibitors generally yield better results than membrane inhibitors or passivators. The protection afforded by interface inhibitors depends on their structure, the chain length and in the case of the pyridine components investigated the nature and position of the substituents in the pyridine ring.
    Notes: Es wurde untersucht, ob für die Erprobung von Kavitationsinhibitoren neben der gravimetrischen Methode auch elektrochemische Prüfverfahren eingesetzt werden können. Es wurde ferner der Zusammenhang zwischen Struktur des Inhibitors, Art und Form des Kavitationsangriffes und Mechanismus der Zerstörung untersucht. Diese Arbeit wurde mit einer Gruppe herkömmlicher Kühlwasserinhibitoren sowie mit einigen Pyridinverbindungen durchgeführt.Wie es sich zeigte, sind elektrochemische Untersuchungen weniger geeignet, eine Inhibitorauswahl bei hohen Kavitationsintensitäten zu ermöglichen, da die elektrochemische Metallauflösung nur einen relativ kleinen Teil des gesamten Abtrags ausmacht. Sie sind aber als Ergänzung zu magnetostriktiven Untersuchungen für die Beurteilung des Gesamtverhaltens eines Inhibitors unbedingt notwendig, da es sich gezeigt hat, daß nicht immer ein guter Kavitationsinhibitor mit demselben Erfolg gegen elektrochemische Korrosion eingesetzt werden kann.Wie sich außerdem herausstellte, liefern Grenzflächeninhibitoren in der Norm bessere Resultate als Membraneninhibitoren oder Passivinhibitoren. Bei den Grenzflächeninhibitoren ist die Schutzwirkung von der Struktur des Inhibitors abhängig, wobei insbesondere Kettenlänge und - bei den untersuchten Pyridinverbindungen - Art und Stellung der Substituenten eine wichtige Rolle spielen.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 27 (1976), S. 693-697 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Material tests at high-velocity flowsA corrosion test rig was developed making possible visual observation of the behaviour of metal when exposed to corrosive environments, such as aggressive media at high or low velocities. Pressures up to 15 bar, temperatures up to 150 °C are possible. Fluid velocities range from 5 to 80 m/s, or even to 100 m/s for short runs. Boiler water, seawater and various acids are the media used. Test runs with different test materials using hot brine as electrolyte have shown, that the behaviour of the material can be evaluated after a short run time.
    Notes: Für die Untersuchungen von Korrosionsvorgängen wurde eine Prüfeinrichtung entwickelt. Diese Anlage ermöglicht es, gravimetrische und elektro-chemische Messungen durchzuführen und die Vorgänge während der Prüfzeit optisch zu beobachten. Der Einsatzbereich erstreckt sich auf Drücke bis max. 15 bar, Temperaturen bis + 150°C und Strömungsgeschwindigkeiten bis zu 100 m/s, wobei auch aggressive Medien verwendet werden können. Mi Hilfe dieser Einrichtung wurde die Erosionskorrosionsbeständigkeit von verschiedenen Werkstoffen in heißen Solen untersucht. Es zeigte sich, daß schon nach verhältnismäßig kurzer Zeit eine Differenzierung der Werkstoffe möglich ist.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...