    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of environmental contamination and toxicology 16 (1976), S. 495-502 
    ISSN: 1432-0800
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 3 (1977), S. 15-26 
    ISSN: 1432-1238
    Keywords: Trend Detection ; Prediction ; Patient Monitoring ; Microprocessor
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract An investigation has been carried out into the suitability of the following techniques for trend detection and forecasting in patient monitoring: Cusum; Trigg's Tracking Signal; The Patient Condition Factor; The Patient Alarm Warning System; Box-Jenkins models and the Harrison-Stevens Bayesian approach. The latter holds considerable promise since it is flexible and can be implemented on a microprocessor. Consideration has also been given to the need for a better knowledge of the statistical properties of the variables to be monitored and the problems of combining trends detected in severable variables.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 2 (1976), S. 3-6 
    ISSN: 1432-1238
    Keywords: Impedance cardiogram ; Cardiac output ; Stroke volume ; Averaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In six volunteers (5 male, 1 female) it has been shown that normal respiration made no statistical difference to the estimates of the mean stroke volume and the mean cardiac output as determined by the electrical impedance method of Kubiceket al, (1966). The coefficient of variation was usually increased by respiration. The use of those stroke volumes which occur only at end-expiration was not shown to yield a greater reproducibility with 3 other male volunteers. In the female subject it was found that the use of a digital averager triggered from the preceding R-wave of the ECG gave values for the mean stroke volume and cardiac output which were always lower than the conventional mean values obtained from a number of strokes. The expense of either of these approaches does not appear to be justified as a means of compensating for the effects of normal respiration on the impedance dZ/dt waveform.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1238
    Keywords: Blood Resistivity ; Cardiac Output ; Electrical Impedance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A relationship has been established between the haematocrit and the resistivity of whole blood at 37°C for neonates and adults not suffering from renal failure. Values of resistivity obtained in this way were substituted into Kubicek's equation for stroke volume by the electrical impedance technique, the signal pick-up electrodes being placed in standard positions. The calculated cardiac outputs were then compared with those obtained simultaneously from other techniques such as the dye dilution method for adults and the measurement of pulmonary effective capillary blood flow by rebreathing nitrous oxide in neonates. It was found that the impedance method overestimates under these circumstances, and other workers have shown that this is likely to be due to a contribution from the right heart. A haemotocrit-dependent correction factor has been employed in the case of neonates to align the impedance and nitrous oxide results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 3 (1977), S. 35-39 
    ISSN: 1432-1238
    Keywords: Transcutaneous ; Oxygen tension ; Intensive Therapy Unit ; Adult ; Neonatal Care Unit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The use of transcutaneous monitoring of the PO2 in patients in an adult intensive therapy unit has been found to be a simple and reliable procedure. The electrodes were heated to 44°C in order to obtain a near maximal response. In individual patients, the transcutaneous reading may be up 20 per cent different from the arterial value. However, the difference is reproducible for a given patient and does not detract from the value of the technique in following trends. The ease of use of the non-invasive transcutaneous technique has brought to light numerous instances of marked fluctuations occurring in patients oxygen tensions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1238
    Keywords: Thoracic impedance ; Haemorrhage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The correlations between the haemodynamic and transthoracic electrical impedance changes resulting from a progressive reduction in the circulating blood volume were studied in four intact mongrel dogs artificially ventilated with a mixture of halothane in nitrous oxide-oxygen. The cardiac output of the dogs was measured by both the electrical impedance and the fibre optic dye dilution techniques. It was found that significant correlations existed between the blood loss and the arterial blood pressure, the maximum first derivative of the transthoracic impedance, the Heather Index, the transthoracic impedance, the maximum rate of change of aortic pressure and the cardiac stroke work. There was also a good correlation between the dye and impedance cardiac output values, the impedance value always being higher than the corresponding dye value. The correlation between the Heather Index and the PEP/LVET ratio and 1 /PEP2 varied markedly from dog to dog.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 14 (1976), S. 432-435 
    ISSN: 1741-0444
    Keywords: Bladder e.m.g. ; Cervix e.m.g.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Electromyographic studies of various smooth muscle organs have been made by different workers to define the normal physiology and to try to elucidate the nature of some pathological conditions. High-frequency low-voltage activity has been recorded previously from both the uterus and the bladder. Low-frequency high-voltage activity recorded from the bladder and from the gastrointestinal tract has been shown to correlate with different pathological disorders. The paper describes the low-frequency high-voltage electromyographic activity, previously unreported, which can be recorded from the cervix uteri, and discusses the means of computer frequency analysis in the quantisation of such signals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 15 (1977), S. 1-1 
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 14 (1976), S. 74-78 
    ISSN: 1741-0444
    Keywords: Impedance cardiograph ; Analogue computer ; Stroke volume ; Cardiac output
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire L'article décrit un circuit analogue servant à mesurer les volumes de battement pour usage en conjonction avec l'e.c.g.dZ/dt et les signaux phonocardiogrammes produits par un cardiographe d'impédance IFM. L'affichage est effectué sur un cadran numérique. Ce circuit peut être étendu pour mesurer le rendement cardiaque.
    Abstract: Zussammenfassung Es wird eine Analogschaltung zum Einsatz in Verbindung mit dendZ/dt-, e.k.g.-und Phonokardiogrammsignalen von einem IFM-Impedanz-Kardiographen zur Messung des Hubvolumens beschrieben. Die Anzeige erfolgt auf einem digitalen Meßgerät. Die Schaltung kann zur Messung der Herzleistung erweitert werden.
    Notes: Abstract An analogue circuit is described for use in conjunction with thedZ/dt, e.c.g. and phonocardiogram signals from an IFM Impedance Cardiograph to measure stroke volume. This is displayed on a digital meter. The circuit can be extended to measure cardiac output.
    Type of Medium: Electronic Resource