Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European archives of oto-rhino-laryngology and head & neck 216 (1977), S. 644-645 
    ISSN: 1434-4726
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The caloric stimulation is the only possibility how the otolaryngologist may examine separately the function of the vestibular organs. But in patients with chronic mesotitis and a tympanic perforation, we were not able to irrigate the labyrinths, and therefore had no knowledge of labyrinthic defects in those patients. Our new method — called thermostimulator — now allows us, to irrigate the ears with tympanic perforations. 75 patients were tested. 50 ears with a central perforation had a labyrinthine defect of 9.5% compared with the normal side, in 33 ears with a cholesteatoma, we found a defect of 33.2%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 169 (1977), S. 243-251 
    ISSN: 1433-8580
    Keywords: Ultrastructure ; arterial prostheses ; lyophilized human dura ; neointima ; Ultrastruktur ; arterielle Gefäßprothesen ; lyophilisierte menschliche Dura ; Neointima
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung 5 aus lyophilisierter menschlicher Dura (LMD) hergestellte und Hunden implantierte Arterienprothesen wurden nach 4, 5 1/2, 13, 43 und 46 Monaten entnommen und elektronenmikroskopisch untersucht. Die Neointima aller Implantate bestand aus Pseudo-Endothelzellen, Fibrozyten und Kollagenfibrillen. 43 und 46 Monate nach Implantation waren außerdem glatte Muskelzellen und elastische Mikrofibrillen in der Neointima vorhanden. Diese entsprach somit in ihrer Zusammensetzung im wesentlichen der Neointima von Kunststoff- und Kollagen-Kunststoff-Arterienprothesen. Die klinische Erprobung von LMD-Implantaten als arterieller Gefäßersatz ist jedoch wegen degenerativer Wandveränderungen in den Prothesen mit fast vierjähriger Verweildauer vorerst noch zu früh.
    Notes: Summary Five arterial prostheses made of lyophilized human dura (LHD) were inserted into dogs and removed after 4, 5 1/2, 13, 43, and 46 months to be studied with the electron microscope. The neointima of all grafts consisted of pseudo-endothelial cells, fibrocytes, and collagen fibrils. Additionally, 43 and 46 months after implantation smooth muscle cells and elastic microfibrils were present. Thus, the composition of the neointima was substantially identical with that of the neointima of synthetic arterial grafts and collagenfabric ones. The clinical application of arterial prostheses of LHD, however, seems at present too early because of degenerative changes in the walls of those grafts which remained nearly 4 years in the dogs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 287 (1977), S. 257-263 
    ISSN: 1618-2650
    Keywords: Elementaranalyse von Organ. Verbindungen ; Datenverarbeitung und Automatisierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Prozeß-Datenverarbeitungs-System in einem Laboratorium für organische Mikroelementaranalyse wird beschrieben. Die Meßwerte von den Elektrowaagen und den Analysenautomaten werden auf 50 Leitungen über eine Datensammelstation in real-time an einen Prozeßrechner übergeben. Der Rechner sammelt und sortiert die Werte und druckt bei Richtigkeit eine Analysenerledigung. Andernfalls werden Fehlerwarnungen gegeben und der weitere Ablauf des betreffenden Analysenautomaten wird gestoppt.
    Notes: Summary A data processing system suitable for a laboratory for organic micro elemental analysis is described. The data of the electronic balances and the automatic analytical instruments are transferred on 50 lines via a data collecting system in real time to a computer. The computer collects and classifies the data and, if consistent, prints out an analytical report. Otherwise alarm is given and the running of the automated analytical instrument concerned is stopped.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Blends of poly(vinyl chloride) (PVC) and chlorinated poly(ethylene) (CPE) form a high impact polymer multiphase system. Characterization of this system by electron microscope becomes possible by a new pretreatment procedure of the polymer blend. The investigation of the morphology by this method shows the initial separation of secondary PVC particles (50-200 μm) into primary PVC particles (0,1-1 μm) by the soft CPE-phase. Due to the stability of the primary PVC-particles an interpenetrating network of the two phases is formed dependent on temperature and shear conditions of the melt Above a specific temperature PVC primary particles melt and the interpenetrating network is transformed into a system of fine dispersed CPE-particles in a PVC matrix Similar results are obtained in the system PVC/poly(ethylene-co-vinyl acetate) and PVC/poly(methyl methacrylate-co-butadiene-co-styrene).
    Notes: Blends aus Polyvinylchlorid (PVC) und chloriertem Polyäthylen (CPE) bilden ein schlagzähes Zweiphasensystem, welches bisher elektronenmikroskopisch nicht untersucht werden konnte. Durch ein neues chemisches Kontrastierungsverfahren wird die Abbildung des Zweiphasensystems im Elektronenmikroskop möglich. Aus den Morphologieuntersuchungen geht hervor, daß zu Beginn der Schmelzverarbeitung des Blends PVC-Sekundärkörner (50-200 μm) durch die Weichphase in Primärkörner (0.1-1 μm) separiert werden. Durch die endliche Stabilität der PVC-Primärkörner während der Verarbeitung. abhängig von Temperatur und Scherung in der Schmelze, bildet sich ein Kautschuknetzwerkäs. Verlieren die PVC-Partikel durch Zusammenschmelzen ihre Identität, bricht das Kautschuknetzwerk zusammen. und der Kautschuk wird in der Hartmatrix fein dispergiert. Ähnliche morphologische Verhältnisse werden in den Schlagzähsystemen Polyvinylchlorid und Äthylen/Vinylacetat-Copolymeren bzw. Polyvinylchlorid und Methylmethacrylat/Butadien/Styrol-Terpolymeren angetroffen.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...