Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Orthopäde 26 (1997), S. 489-497 
    ISSN: 1433-0431
    Keywords: Key words Biodegradation ; Polylactide ; Medial ankle fracture ; Distal radius fracture ; Radial head fracture ; Schlüsselwörter Biodegradation • Polylactid • Innenknöchelfraktur • Radiusfraktur • Radiusköpfchenfraktur
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Biodegradable Implantate bieten gegenüber metallischen Implantaten Vor- und Nachteile. Zahlreiche Anwendungsideen stellen sich dar. Darunter ist der Fixationsstift für gering belastete osteochondrale Fragmente am gründlichsten untersucht. Die primäre Festigkeit für Anwendungen am distalen Radius wurde vergleichbar zu herkömmlichen Implantaten wie der 1,8-mm-Kirschner-Draht gemessen. Eine prospektiv randomisierte Studie mit 183 Radiusköpfchenfrakturen zeigte gleichwertige Ergebnisse bei Metall und Polymer und insbesondre keine erhöhte Komplikationsrate für die Stifte aus Polylactid (Polypin®). Für diese Indikation und vergleichbare Lokalisationen ist eine Anwendung zu empfehlen. Die Gesamtbehandlungskosten können damit gesenkt werden, auch wenn das einzelne Implantat teurer ist. Hochfeste Polylactidschrauben haben in einer klinischen Langzeitstudie extrem lange Resorptionszeiten von 5–7 Jahren erbracht.
    Notes: Summary The application of biodegradable implants is combined with advantages and disadvan- tages. They offer a great deal of innovative ideas. Best evaluation has been done with pins for the fixation of low loaded osteochondral fractures. When using 2,7 mm Polypin® primary mechanical stabilility of distal radius fractures is comparable with the fixation by 1,8 mm K-wires. A prospective and randomised study with two years follow up, including 183 radial head fractures, showed no significant difference in results and complications in metal and polyactide implants. For this localisation and other comparable indications the implant can be recommended. Despite the more extensive degradable device overall costs can be reduced with the polymer implant. Orien- truded polyactide screws showed good clinical results, newetheless resorption was extremely late within 5 to 7 years.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-044X
    Keywords: Key words Foreign-body reactions • Biocompatibility • Biodegradable implants • Classification • ; Osteolysis ; Schlüsselwörter Fremdkörperreaktionen • Biokompatibilität • Biodegradierbare Implantate • Klassifikation • Osteolysen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Biodegradierbare Implantate finden zunehmend Einsatz in Unfallchirurgie und Orthopädie. Die Anzahl der erhältlichen Implantate und der dabei eingesetzten verschiedenen Polymere nimmt ständig zu, wobei die Biokompatibilität problematisch bleibt. Diese wird von einer Vielzahl verschiedener Faktoren beeinflußt. Lokale Fremdkörperreaktionen können bei der Verwendung biodegradierbarer Implantate auftreten und müssen klinisch dokumentiert werden. Um eine Vergleichsmöglichkeit verschiedener Implantate zu ermöglichen, ist ein standardisiertes Instrument zur Klassifizierung solcher Fremdkörperreaktionen erforderlich. Basierend auf unseren klinischen und experimentellen Erfahrungen wurde ein Klassifikationssystem entwickelt, das eine systematische Dokumentation gewährleistet. Hierzu werden Fremdkörperreaktionen in Osteolysen (O-0 bis O-4), extraartikuläre (EA-0 bis EA-4) und intraartikuläre (IA-0 bis IA-4) Weichteilreaktionen unterteilt.
    Notes: Summary Biodegradable implants are increasingly used in orthopedic and trauma surgery. Many different implants consisting of different biodegradable polymers are currently available. Different factors contribute to the biocompatibility of these implants, and local foreign-body reactions remain a matter of concern. Therefore, it is mandatory to document and compare the tissue reactions caused by various biodegradable implants in experimental or clinical studies. We have developed a standardized system of classification based on our previous experimental and clinical observations. Foreign-body reactions are differentiated into osteolyses (O-0 to O-4), extra-articular (EA-0 to EA-4) and intra-articular (IA-0 to IA-4) soft-tissue reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 366 (1985), S. 633-634 
    ISSN: 1435-2451
    Keywords: Flail chest ; Operative stabilization ; Polytrauma ; Artificial respiration ; Instabiler Thorax ; Operative Thoraxwandstabilisierung ; Polytrauma ; Beatmungsdauer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Aus 103 Polytraumatisierten mit Thoraxverletzung aus den Jahren 1980–1982 wurden 2 Gruppen mit je 15 konservativ and operativ behandelten Thoraxwandinstabilitaten ausgewertet. Die konservative Gruppe zeigte bei geringerem Verletzungsgrad schlechtere Ergebnisse: Mittelwerte konservativ operativ Anzahl Rippenfrakturen je Patient 6,6 9,1 Polytraumaschlüssel Thorax 14,8 22,7 Polytraymaschlüssel Gesamtverletzung 32,17 36,4 Verstorben, Überlebenszeit (Tage) 13/15, 8, 1 10/15, 21, 0 Beatmung (Tage) Überlebender 7,3 4,6
    Notes: Summary In 1980–1982, 103 patients with polytrauma and flail chest were treated. Fifteen patients who had undergone surgical stabilization were compared to 15 with conservative treatment. Although the conservative group had less severe traumata the clinical results were worse:
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 366 (1985), S. 638-638 
    ISSN: 1435-2451
    Keywords: Ligament rupture ; Augmentation replacement ; PDS ; Kreuzbandruptur ; Augmentationsplastik ; PDS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In einer Pilotstudie werden nach vorausgegangenen tierexperimentellen Untersuchungen eine resorbierbare Kordel aus PDS mit Fascia-lata (n= 13) bzw. Patellarsehnen bei 15 Patienten mit frischer isolierter vorderer Kreuzbandruptur (n=2), frischer anteromedialer Komplexinstabilität (n=2), veralteter isolierter vorderer Kreuzbandruptur (n =10) sowie veralteter anteromedialer Komplexinstabilitat (n= 1) i. S. einer Augmentationsplastik eingesetzt. Die Nachuntersuchungen der Patienten zwischen 7 and 33 Monate nach der Operation ergab nach den Kriterien von Böhler and Trojan, in denen subjektive and objektive Befunde gewertet werden, 5mal ein ausgezeichnetes, 4mal ein gutes and 1mal ein mäßiges Ergebnis. Diese Nachuntersuchungsergebnisse berechtigen zum weiteren Einsatz von PDS als Augmentation von körpereigenen Materialien bei Verletzungen von Bandstrukturen, wobei nicht nur Bänder des Kniegelenks ersetzt werden können.
    Notes: Summary After preliminary animal experiments, we conducted a pilot study on a resorbable replacement combined with fascia lata (n = 13) or ligament of the patella, which was used as augmentation replacement in 15 patients with acute isolated rupture of the anterior cruciate ligament (AC 2), acute instability of the anterior medial complex (n=2), isolated rupture of the ACL (n= 10), as well as an old instability of the anterior medial complex (n= 1). Follow-up of the patients 7 to 33 months after the operation showed, according to the criteria of Bohler and Trojan, excellent results in 5 patients, good results in 4, and fair results in 1. These results indicate that PDS should be used further to augment human materials in ligament injuries, as not only the ligaments of the knee could be replaced by its use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...