Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004
  • 1990-1994  (2)
  • 1985-1989  (1)
  • 1980-1984
  • 1975-1979
  • 1920-1924
  • 1992  (2)
  • 1988  (1)
Material
Years
  • 2000-2004
  • 1990-1994  (2)
  • 1985-1989  (1)
  • 1980-1984
  • 1975-1979
  • +
Year
  • 1
    ISSN: 1432-1238
    Keywords: Subcutaneous oxygens tension ; Transcutaneous oxygen tension ; Tissue perfusion ; PEEP ; Cardiac output ; Oxygen delivery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To compare subcutaneous (PscO2) and transcutaneous (PtcO2) oxygen tension measurements in relation to hemodynamic variables at different levels of PEEP, and to evaluate the usefulness of these measurements as monitors of peripheral tissue perfusion. Design Prospective trial. Setting Intensive care unit in a university hospital. Patients Seven patients with gastric cancer who where undergoing total gastrectomy. Interventions Silicone catheter was placed in the upper arm and transcutaneous oxygen monitor was placed on the upper part of the chest. A pulmonary artery catheter was placed in the right pulmonary artery. Measurements and results PscO2 and PtcO2 together with hemodynamic variables were measured at different levels of PEEP. Progressive increase of PEEP reduced cardiac index (CI) (p〈0.05) with a concomitant decrease of PscO2 (p〈0.05) and oxygen delivery (DO2) (p〈0.05). Changes in PtcO2 parallelled changes in arterial oxygen tension (PaO2), but no correlation was found between PtcO2, CI and DO2. Conclusion PscO2 is a sensitive indicator of subcutaneous tissue perfusion, which can be used to identify the PEEP level, with optimum peripheral perfusion. PscO2 seems to be a more reliable indicafor of tissue perfusion than PtcO2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Combinatorica 12 (1992), S. 27-37 
    ISSN: 1439-6912
    Keywords: 52 A 25 ; 90 C 10
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Abstract We give an upper bound on the number of vertices ofP I , the integer hull of a polyhedronP, in terms of the dimensionn of the space, the numberm of inequalities required to describeP, and the size ϕ of these inequalities. For fixedn the bound isO(m n ϕ n− ). We also describe an algorithm which determines the number of integer points in a polyhedron to within a multiplicative factor of 1+ε in time polynomial inm, ϕ and 1/ε when the dimensionn is fixed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0021-9541
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: The binding of iodinated basic fibroblast growth factor (bFGF) to low-density heparan sulfate proteoglycan purified from the Engelbreth Holm Swarm (EHS) sarcoma was investigated using different techniques. The tumor clearly contained bFGF, the level being comparable to that found in other tissues such as human or bovine brain. 125I bFGF strongly bound to the basement membrane-like matrix of EHS frozen sections as revealed by autoradiography. Iodinated bFGF bound to purified heparan sulfate proteoglycan but not to laminin or collagen type IV, three components isolated from the same tumor. In contrast, acidic fibroblast growth factor (aFGF) displayed negligible binding to heparan sulfate proteoglycan. Binding of bFGF to frozen sections and to purified proteoglycan could be strongly inhibited by heparin and was displaced by an excess of unlabeled factor and completely suppressed after heparitinase and heparinase treatments. Binding was a function of the salt concentration and was abolished at 0.6 M NaCl. Scatchard analysis indicated the affinity site had a Kd of about 30 nM, a value 10-15 higher than that recently reported by Moscatelli (J. Cell. Physiol., 131:123-130, 1987) in the case of the low-affinity binding sites present on the surface of baby hamster kidney (BHK) cells.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...