Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (5)
  • 1955-1959
  • 1989  (5)
Material
Years
  • 1985-1989  (5)
  • 1955-1959
Year
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 93 (1989), S. 2563-2569 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Irradiation experiments on biological samples with monochromatic ultrasoft x-rays are inevitable in elucidating the initial process in radiobiological phenomena. However, intense light sources with continuous spectra in this wavelength region have not been available until recently. Synchrotron radiation is the best light source for the study because of its intense, continuous emission spectrum. The purpose of the project is to develop a grazing incidence ultrasoft x-ray monochromator for radiation biology studies using synchrotron radiation as a light source. The following characteristics are required in the monochromator, namely, (1) high throughput with moderate resolution; (2) wide beam area with uniform intensity; (3) little contamination of higher order lights; and (4) easy operation and maintenance. Considering the above requirements, a plane-grating type monochromator (PGM) is adopted. The monochromator consists of two premirrors (M1 and M2), a plane grating (1200 l/mm), a concave focusing mirror (r=12 m) and an exit slit. Two premirrors with different incident angles can be used interchangeably to eliminate higher order lights in the desired wavelength region. Wavelength of 30–70 A is available when M1 is used and 80–250 A when M2 is used. Expected wavelength resolution is 1% when the width of exit slit is 300 μm. All vacuum chambers accommodating these optical elements are bakable in order to attain ultrahigh vacuum. Wavelength is controlled by a microcomputer system equipped with a stepping motor and an encoder. This monochromator will be installed at beamline 12C at the Photon Factory, National Laboratory for High Energy Physics, and will be open to outside users in radiation biology by the end of 1988.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 66 (1989), S. 1045-1050 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A computer simulation method to study a laser-induced transient temperature profile of a multilayered phase-change optical recording disk (PCORD) has been developed. The simulation program consists of two parts. One part is an optical analysis program based on the optical characteristic matrix method, and the other is a thermal analysis program based on the finite-element method. A new estimation method for thermal conductivity of recording films was proposed. The estimated thermal conductivity of the thin-film recording media was found to be 50% lower than that of the bulk. Reflectivity, absorbance, and temperature values obtained with this simulation method were compared with those measured by a spectrophotometer and an infrared radiation thermometer when the samples were irradiated in an Ar+ laser beam. The accuracy using this simulator was within 8% for reflectivity and absorbance and within 10% for temperature. A method of optimizing the laser-absorbing layer was studied. With this method simulations showed that the PCORD had a maximum contrast ratio and minimum recording time when thickness, thermal conductivity, and complex refractive index of the laser-absorbing film were 60 nm, 4.2×10−3 W/cm °C, and 2.6−i⋅0.0, respectively. This simulation could provide better film designs for PCORDs and the other optical disks of heat mode recording.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford [u.a.] : International Union of Crystallography (IUCr)
    Acta crystallographica 45 (1989), S. 1415-1417 
    ISSN: 1600-5759
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 10 (1989), S. 819-831 
    ISSN: 1572-9567
    Keywords: high temperature ; molten salt ; oscillation viscometer ; sodium chloride ; viscosity
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The viscosity of molten sodium chloride (NaCl) has been measured in the temperature range 1083–1248 K by the oscillating-cup method. Although NaCl was considered as one of the standard salts, there existed a systematic deviation among the available data. The present measurement is the redetermination after checking the effects of the meniscus at the liquid surface and of the temperature field.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...