Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (2)
  • 1970-1974
  • 1990  (2)
  • Rupture of the supraspinatus tendon  (1)
  • quantitative XPS  (1)
Material
Years
  • 1990-1994  (2)
  • 1970-1974
Year
  • 1990  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 12 (1990), S. 161-165 
    ISSN: 1279-8517
    Keywords: Shoulder joint ; Rotator cuff ; Supraspinatus tendon ; Rupture of the supraspinatus tendon ; Vascular study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé La vascularisation de la coiffe des rotateurs a été étudiée sur 22 épaules de sujets adultes après injections vasculaires d'un mélange de gélatine et d'encre de Chine et analyse du réseau vasculaire du tendon du m. supra-épineux au microscope électronique. On a ainsi constaté que les vaisseaux du tendon du m. supra-épineux provenaient essentiellement de l'a. circonflexe antérieure de l'humérus et de l'a. suprascapulaire. Macroscopiquement, on peut voir à la surface de ce tendon une zone avasculaire ou une zone critique dont le bord externe est situé à 7 ou 8 mm en moyenne de l'insertion osseuse de ce tendon. La surface de cette zone avasculaire augmente avec l'âge.
    Notes: Summary The vascular supply of the rotator cuff in 22 adult shoulders was studied by way of mixture infusion of gelatin and India ink and vascular cast, in combination with Scanning Electronic Microscopy of the vascular pattern in the supraspinatus tendon. It was found that the vessels of the supraspinatus tendon mainly derive from the anterior circumflex humeral and suprascapular arteries. Macroscopically, an avascular zone or critical zone could be seen on the surface of supraspinatus, and the mean distance of the external edge from the osteo-tendinous attachment was 7.8 mm. The area of the avascular zone increased with age.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4889
    Keywords: Ni-Cr alloys ; transient oxide structures ; quantitative XPS ; Auger ; TEM ; SEM
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract Low pressure oxidation studies of Ni-18%Cr alloy were carried out at temperatures of 500–600°C for very brief periods. Detailed XPS, AES, SEM, and TEM studies identified four stages in the initial oxidation. These are: (1) formation of a mixed nickel-chromium oxide overlayer; (2) growth of submicron-sized oxide nodules; (3) development of dark “hole-like” patches on the surface; and (4) growth of “second generation” oxide nodules. Both types of nodules consist primarily of a nickel structure depleted in oxygen. Their formation appears to result from a very rapid outward movement of nickel from localized defects in the metal. The dark patches result from the presence of a chromium oxide-rich underlayer, which appears to form by a lateral migration of chromium from adjacent oxide/metal interface regions and from grain boundaries.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...