Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 85-90 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phenolic compounds ; Ion-pair solid phase extraction ; On-line trace enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 μg 1−1 and 20 μl−1 and limits of determination between 0.5 μg l−1 and 1 μg l−1 are obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Solid-phase extraction ; Gas chromatography ; Ion trap tandem mass spectrometry ; Water samples ; Environmental analysis ; Pesticides ; Bromide ; Nitrite
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On-line solid-phase extraction-gas chromatographyion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90°C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1–500 ng L−1, using a sample volume of 10–100 mL for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01–4 ng L−1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L−1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L−1, respectively.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 41 (1995), S. 521-526 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phenolic compounds ; Ion-pair solid phase extraction ; On-line trace enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Modifying the most common design for the on-line coupling of a precolumn to reversed phase LC with diode array detection has resulted in reduction of the broadening of the peaks which results when the compounds of interest are strongly retained by a highly hydrophobic sorbent. The modification consists of the desorption of the analytes trapped on the precolumn solely by the organic solvent used to modify the solvent strength of the mobile phase. Results obtained using this design were compared with those obtained with the conventional design, with C18 and PLRP-S precolumns. The performance of the system was also tested with a highly cross-linked styrene-divinylbenzene copolymer (ENVI-chrom P) precolumn for the determination of phenolic compounds in real samples. The advantages and disadvantages are discussed. Ion-pair solid phase extraction is used in order to increase the breakthrough volumes of more polar compounds, mainly phenol. The use of the new design enables phenolic compounds to be determined at the low μg L−1 level with limits of detection ranging between 0.1 and 2 μg L−1 in tap water when a 10 mL sample was analyzed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...