Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (1)
  • 1995-1999  (1)
  • 2002  (1)
  • 1995  (1)
Material
Years
  • 2000-2004  (1)
  • 1995-1999  (1)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Scandinavian journal of medicine & science in sports 12 (2002), S. 0 
    ISSN: 1600-0838
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Sports Science
    Notes: The purpose of this study was to investigate the viscoelastic properties of tendon structures in humans. Elongation of the tendon and aponeurosis of medial gastrocnemius muscle (MG) was directly measured by ultrasonography, while subjects (n=19) performed ramp isometric plantar flexion up to the voluntary maximum, followed by a ramp relaxation. The relationship between tendon elongation (L) and estimated muscle force (Fm) was fitted to a linear regression, the slope of which was defined as compliance of the tendon structures. The hysteresis was calculated as the ratio of the area within the L-Fm loop (elastic energy dissipated) to the area beneath the load portion of the curve (elastic energy input). The resulting L-Fm relationship was non-linear in form, as previously reported on animal and human tendons in vitro. The mean compliance was 4.5±1.1  ·  10−2 mm/N. However, there was a considerable inter-subject variability (2.9 to 7.2  ·  10−2 mm/N). The Young's modulus, i.e., the slope of the stress–strain curve, was 280 MPa, which tended to be lower than the previously reported values for human tendons. It was also found that the strain of the tendon structures was homogeneously distributed along their length. The mean hysteresis (energy dissipation) was 22.2±8.8%. However, again there was a considerable inter-subject variability (9.7 to 37.2%). The present results indicated that the tendon structures of human MG were considerably compliant and their hysteresis was in accordance with previously reported values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Digital radiography ; Image processing ; Subtraction ; Thorax ; Tomography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Digital tomosynthesis makes it possible to reconstruct multiple tomographs from digital data obtained during a single tomographic motion and permits digital processing, which adds a number of special advantages to the well-known advantages of conventional tomography. We performed digital tomosynthesis with a fluororadiographic TV unit with tomographic function which was capable of producing pulsed low-and high-energy X-rays alternately, and we studied digital image processing to improve the image clarity of the reconstructed tomographs. To identify the optimal parameters for processing image data by means of spatial frequency filtration we evaluated the spatial frequency distribution of image data in linear tomographs of the lung, and on the basis of the results of this study we developed several types of digital image processing to reduce tomographic blur and system noise, to improve visualisation of faint opacities, to reduce resistant tomographic blur as well as overall blur, and to generate low-noise bone images based on dual-energy subtraction tomosynthesis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...