ISSN:
1588-2780
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
,
Energy, Environment Protection, Nuclear Power Engineering
Notes:
Abstract This procedure for determining Fe-55 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant, long-lived radionuclides associated with contaminated piping, hardware, and concrete for several decades of years after shutdown. The analysis of Fe takes about three hours until the measurement with an anticoincidence shielded LSC Quantulus 1220 starts. The decontamination factors are ranging from greater than 105 to 109 for all important naturally and artificially occurring radionuclides except Sb. The chemical yield stays constant at a value of about 92% up to 0.1 g stable Fe in steel, concrete or other material. The detection limits (confidence level 95%) reach values of 8 mBq per sample or about 60 mBq/g steel and 1.5 mBq/g concrete at a counting time of 1000 minutes. Four to eight analyses are performed by one technician during eight hours.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF02041925
Permalink