Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • 1990-1994
  • 1995  (3)
Material
Years
  • 1995-1999  (3)
  • 1990-1994
Year
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 103 (1995), S. 6597-6600 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Ab initio self-consistent-field (SCF) and electron correlation calculations have been carried out for the dihedral angle dependence of the vicinal proton–proton coupling constants, 3JHH, in ethane molecule. The four contributions to 3JHH, (JFC, JSD, JOP, and JOD) have been computed with the three different basis sets, [5s2p1d/2s1p], [5s3p1d/3s1p], and [7s4p2d/5s2p]. The Fermi contact (FC) contribution was largest and the spin–dipole (SD) contribution was smallest. The FC and orbital paramagnetic (OP) contributions showed large basis set dependence, but the SD and orbital diamagnetic (OD) contributions presented little basis set dependence. The calculated total SCF contribution to 3JHH was higher than the experimental coupling. Using the Møller–Plesset perturbation theory we have introduced electron correlation effects on the FC and OP terms. The correlation effects on the OP term was shown to be negligible. The second-order correlation in the FC term was very large and amounted to half of its SCF value in magnitude with opposite sign. However, the third-order correlation in the FC contribution was small. Unfortunately, the calculated 3JHH value including correlation corrections through third order was too small compared to the experimental one. The poor agreement between calculation and experiment is claimed to be due to higher than third-order correlations in the FC term. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2218
    Keywords: Esophageal achalasia ; Laparoscopic surgery ; Extramucosal myectomy ; Dor fundoplication ; Intraoperative manometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Laparoscopic extramucosal myectomy with anterior fundoplication according to the Dor technique was performed on a 24-year-old-woman. Intraoperative inflation of a pneumatic balloon made the operative procedures such as extended submucosal dissection quite easy. Intraoperative gastrofiberscopy was useful for confirming that the remaining mucosal layer was not injured after completion of myectomy. Intraoperative manometry confirmed a complete decompression of the high-pressure zone in the lower esophageal sphincter. Complete relief of the symptoms has been recognized for 6 months after operation without any medication. It is considered that these laparoscopic procedures including intraoperative inflation of a pneumatic balloon, gastrofiberscopy, and intraoperative manometry can be used as a standard operation for esophageal achalasia.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 199 (1995), S. 453-463 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Celeste-1 is a lab-scale hot cell intended for R&D work in reprocessing of low burn-up spent fuel elements. The studies are concerned with head-end, first separation cycle by Purex Process using mini mixer-settlers and development of analytical techniques. The analytical monitoring for process control purposes is based on several off-line techniques, such as X-ray fluorescence spectrometry, potentiometric titration, α-and γ-spectroscopy, spectrophotometry, fluorimetry, density measurement and gas chromatography. The analytical treatment takes place in a shielded working place analytical hot cell, glove boxes and hoods and some final measurements are made in the associated analytical laboratory. A pneumatic system is used for transporting analytical samples. All analytical procedures are ready and in operation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...