Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (42)
  • 1985-1989
  • 1960-1964
  • 1997  (42)
  • 1
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Objectives: The aim of this study was to examine the clinical value of QT analysis from Holter recordings in patients after myocardial infarction (Ml).Background: Prolongation and dispersion of QT intervals in the 12-lead standard ECG have been proposed as indicators of risk for arrhythmic events. However, the value of QT and T wave measurements from Holter recordings has yet to be established.Methods: Intervals from Q to the peak and to the end of T were determined every 30 seconds from 24-hour Holter recordings and corrected for cycle length (QTc). The duration of late repolarization was calculated as QT end minus QT peak. 24-hour QT variability was determined as the standard error of estimate from the linear regression analysis of QT and RR intervals. In a case control design, 51 post-MI patients suffering from subsequent cardiac death within 1 year were compared to 51 post-MI patients with an uncomplicated follow-up.Results: QTc intervals as well as 24-hour QT variability did not differ between post-MI patients with favorable and unfavorable clinical outcome. However, there was a prolonged interval from the peak to the end of the T wave in cardiac death victims (mean ± SE: 110 ± 4 ms) as compared to controls (95 ± 3ms, P 〈 0.001).Conclusions: Prolongation of the late repolarization phase seems to be associated with an increased risk of cardiac death after Ml. Standard QT measurements from ambulatory ECG recordings have no predictive value in post-MI patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1471-4159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: We used a catecholaminergic neuron-like cell line (CATH.a cells) as a model system to investigate the likelihood that pituitary adenylate cyclase-activating polypeptide (PACAP) may participate in the regulation of specific gene expression in catecholaminergic neurons. Analysis by reverse transcriptase-PCR amplification revealed the presence in these cells of type I PACAP receptors, with a short isoform, together with a heavier so-called Hop splice variant. PACAP38 and PACAP27 enhanced, in a dose-dependent manner, both cyclic AMP formation and phosphoinositide breakdown, with EC50 values of, respectively, 0.6 × 10−10 and 2 × 10−9M. These peptides, in addition, also elevated [Ca2+]i by mobilizing intracellular calcium pools. Vasoactive intestinal peptide (VIP) was ∼1,000-fold less potent in stimulating cyclic AMP (with EC50 = 2 × 10−7M) and failed to change the turnover of phosphoinositides and to alter [Ca2+]i. Both forms of PACAP, as well as forskolin, stimulated transcriptional induction of tyrosine hydroxylase (TH) and c-fos promoters fused to a chloramphenicol acetyltransferase (CAT) reporter gene in transiently transfected cells (p 〈 0.01 vs. controls). Induction of CAT activity linked to both TH and c-fos promoters was obliterated upon coexpression of a dominant inhibitory mutant (Mt-RAB) of cyclic AMP-dependent protein kinase. We conclude that CATH.a cells do express functional PACAP type I receptors, the activation of which impinges on TH and c-fos transcription according to a process that is primarily dependent on the cyclic AMP-PKA pathway.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical and experimental dermatology 22 (1997), S. 0 
    ISSN: 1365-2230
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 70 (1997), S. 793-795 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We present a time-multiplexed interferometer based on Faraday mirrors, and apply it to quantum key distribution. The interfering pulses follow exactly the same spatial path, ensuring very high stability and self balancing. The use of Faraday mirrors compensates automatically any birefringence effects and polarization dependent losses in the transmitting fiber. First experimental results show a fringe visibility of 0.9984 for a 23-km-long interferometer, based on installed telecom fibers. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0009-6407
    Source: Cambridge Journals Digital Archives
    Topics: History , Theology and Religious Studies
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Fluids 9 (1997), S. 566-586 
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Flow visualization of two highly elastic, nonshear-thinning polyisobutylene/polybutene fluids in the gap between concentric cylinders was performed over a range of shear rates and choices of relative cylinder rotations. The observed secondary flows are discussed in terms of destabilizing elastic and centrifugal forces. In the more viscous, more elastic fluid, instabilities are found to be independent of the choice of rotating cylinder and due entirely to elasticity. At the lowest shear rates examined, the first detectable secondary flows are steady counter-rotating vortices forming after a shearing time more than five orders of magnitude greater than the characteristic relaxation time of the fluid. At somewhat higher shear rates, a much more rapidly appearing oscillatory flow is observed to evolve into the steady vortex structure. In the less elastic fluid, the structure first detectable at the lowest shear rates is again steady vortices regardless of the choice of driving cylinder. At all shear rates examined, only elastic stationary vortices are observed in the absence of centrifugal destabilization (outer cylinder rotating). Secondary flows are significantly stronger in the presence of the centrifugal destabilization due to a rotating inner cylinder. Interaction of elasticity and centrifugal forces is found to generate a number of axially translating vortex structures, many of which are described here for the first time. At a shear rate more than five times the critical, another family of instability is observed which closely resembles a purely elastic instability observed by Baumert and Muller (1995). These experimental results are expected to provide a challenging test of numerical simulations of these viscoelastic flows. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 81 (1997), S. 4846-4846 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Many recent studies of recording and playback in magnetic recording systems have been based on the computer simulation of micromagnetic models of magnetic recording media. Medium models are capable of representing a large class of recording media by selection of appropriate values of model parameters representing the intrinisic properties of the recording medium material. Such parameters include grain size, anisotropy energy density, and exchange energy constant. Largely missing in these studies, however, has been a discussion of how to identify a set of parameter values to represent a particular medium of interest. In this presentation, we describe an identification procedure for selecting the values of the five intrinsic parameters of a micromagnetic medium model to represent a recording medium for which the following hysteresis properties are known: remanent magnetization, coercivity, remanence squareness, and coercivity squareness. Calculation of hysteresis loops verifies that the particular instance of the medium model identified by this procedure reproduces the hysteresis behavior of the medium of interest. Comparison of computer simulations of recording operations to measured recording performance of a medium on a laboratory tester may then be meaningfully made.© 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of advanced nursing 26 (1997), S. 0 
    ISSN: 1365-2648
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The researchers wanted to obtain insight into the cooperation between physicians and nurses with regard to active euthanasia and physician-assisted suicide (EAS). In study I a stratified random sample of 203 clinical specialists, 152 general practitioners (GPs) and 50 nursing home physicians (NHPs) participated. In study II a random sample of 521 GPs was drawn from the province of North Holland and a random sample of 521 GPs was drawn from the rest of the Netherlands. For study III all NHPs were approached. Data were collected by means of an interview in study I. In studies II and III an anonymous, postal questionnaire was used. Approximately half of the GPs did not consult with nurses about a patient's request for EAS, the intention to administer EAS, and the actual administration. In 5% of cases, the NHPs and the specialists did not consult with nurses concerning these aspects. The GPs and NHPs indicated in 4% and 3% of the cases, respectively, that nurses administered the lethal drug(s) to the patients; the corresponding figure for the specialists was 21%. Almost all GPs and NHPs and about three-quarters of the specialists thought that nurses should never be allowed to administer EAS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1546-170X
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Medicine
    Notes: [Auszug] Excessive binding of Plasmodium falciparum-infected red blood cells (pRBCs) to the vascular endothelium (cytoadherence) and to uninfected erythrocytes (rosetting) may lead to occlusion of the microvasculature and thereby contribute directly to the acute pathology of severe human malaria1,2. A ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 30 (1997), S. 557-558 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: A heat-treatment device has been developed in order to analyse the dynamics of structural transformation of powdered materials. This furnace is able to reach 1123 K, with a low-temperature gradient along the quartz capillary and is designed to work on a curved INEL CPS 120 detector with a classical X-ray generator (molybdenum tube). The device permits the collection of a set of recordings at different temperatures during a short period of time for moderately diffractive materials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...