    Notes: Purpose - To analyze effectively magnetic shielding effects by shields with fine structure. Design/methodology/approach - Simplification of the fine structure makes it possible to analyze them efficiently. The authors have introduced a homogenization method to estimate effective permeability of magnetic composite structure for the static field. The homogenization method is applied to the analysis of magnetic shields composed of steel plates and steel rods against DC power lines to test its feasibility. Findings - The properties of the magnetic shielding are analyzed by using the homogenization method. The errors of the magnetic fields increase in case of very few layers. Originality/value - The simplification of the magnetic shields with fine structure by using the homogenization method makes it possible to analyze efficiently magnetic shielding effects, although the accuracy becomes worse in case of very few layers.