Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
  • 1995-1999  (10)
  • 1990-1994  (13)
  • 1955-1959  (1)
  • 1900-1904  (3)
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Geometric and functional analysis 5 (1995), S. 270-328 
    ISSN: 1420-8970
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    ISSN: 1432-119X
    Keywords: Key words Tyrosine phosphatase ; Glucagon ; Pancreatic polypeptide ; Somatostatin ; Endocrine secretion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract  The secretory vesicles of some cells of the islets of Langerhans of the pancreas contain high amounts of immunoreactive tyrosine phosphatase of the PTP1B/TCPTP subfamily. The cells are located in the peripheral parts of the islets and were identified as glucagon- and pancreatic polypeptide-forming cells. The tyrosine phosphatase is also enriched in some of the somatostatin-producing cells but is not elevated either in insulin-producing B-cells or in the exocrine pancreas. Virtually the same patterns were found in pancretic tissues of rats, guinea pigs, pigs, and mice. High levels of detergent-soluble tyrosine phosphatase were measured in the particular fraction of pancreatic islets with a substrate preferred by PTP1B/TCPTP-type protein tyrosine phosphatases.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Inventiones mathematicae 114 (1993), S. 515-563 
    ISSN: 1432-1297
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Knee surgery, sports traumatology, arthroscopy 1 (1993), S. 76-79 
    ISSN: 1433-7347
    Keywords: Laser flowmetry ; Arthroscopic measurement ; Microcirculation ; Blood cell flux ; Laser-Flowmetrie ; Mikrozirkulation ; Arthroskopische Messung ; Vorderes Kreuzband
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Sports Science
    Description / Table of Contents: Zusammenfassung Die Laser-Doppler-Flowmetrie gestattet den Nachweis der Durchblutung im mikrokapillären Bereich von Strukturen unter in vivo-Bedingungen. Wir verwendeten das Lasergerät der Firma Perimed (Schweden) und eine Spezialsonde um die kapilläre Durchblutung des vorderen Kreuzbandes während eines arthroskopischen Eingriffs nachzuweisen. Dabei erhält man Meßwerte in Millivolt, welche relativer Natur sind, ein absoluter Wert der Kapillardurchblutung in Volumen pro Zeiteinheit kann dadurch nich bestimmt werden. Unter standardisierten Bedingungen erfolgte bei 11 Patienten die Durchblutungsmessung und simultane Aufzeichnung auf einem 2-Kanal-Schreiber. In allen Fällen konnten herzsynchrone Pulsationen der kapillären Durchblutung des vorderen Kreuzbandes an 3 Meßpunkten nachgewiesen werden, welche bei Schließen der Blutsperre zur Gänze verschwanden. Wir fanden eine große individuelle Schwankungsbreite der sogenannten Blood-Cell-Flux-Werte von 30 mV bis 620 mV. Die Höhe der herzsynchronen Pulsationen schwankte zwischen 20 mV und 240 mV. Zwischen den einzelnen Meßpunkten oder zwischen den Fluxwerten und der Höhe der Pulsationen konnte nur ein vager Zusammenhang in der linearen Regressionsanalyse gefunden werden, kein Zusammenhang war zwischen den Fluxwerten und dem Blutdruck bzw. dem roten Blutbild nachzuweisen.
    Notes: Abstract Laser Doppler flowmetry permits observation of circulation in the microcapillary regions of structures under in vivo conditions. We used a laser device manufactured by the Swedish company Perimed and a special probe to observe the capillary circulation in the anterior cruciate ligament during arthroscopic surgery. This produces measured values in millivolts: these values are relative in nature and cannot be used to determine an absolute value for capillary circulation by volume per unit time. Under standardized conditions, circulation measurements and simultaneous recordings with a twochannel recorder were made from 11 patients. In all cases, pulsations of the capillary circulation synchronous with the heart beat could be seen on three measuring points on the anterior cruciate ligament; these disappeared upon complete deprivation of blood supply. We found a large individual range of variation in the so-called blood cell flux values from 30 to 620mV. The magnitude of the heart-synchronous pulsations ranged between 20 and 240 mV. Only vague linear relationships were found (a) between the individual measuring points and (b) between the flux values and the magnitude of pulsation; there was no relationship between the flux values and blood pressure and/or red blood count (erythrocyte count, hemoglobin, hematocrit).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    International orthopaedics 15 (1991), S. 357-358 
    ISSN: 1432-5195
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Au cours de 1160 arthroscopies nous avons découvert 16 kystes méniscaux. Nous présentons deux cas de kystes méniscaux intra-articulaires avec des symptômes discrets de blocage et de «douleur antérieure du genou». Dans ces deux cas le diagnostic n'a été fait que grâce à l'arthroscopie.
    Notes: Summary Two cases of unusual location of meniscal cysts were encountered in a large series of arthroscopies of the knee. These cysts were entirely intraarticular in relation to the substance of the lateral meniscus but without any joint line swelling or overt evidence of their presence. The cysts probably accounted for the symptoms of internal derangement of the knee and are likely to be encountered more often with increased used of knee arthroscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Mathematische Zeitschrift 223 (1996), S. 27-45 
    ISSN: 0025-5874
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    ISSN: 1435-2451
    Keywords: VSP ; Transpedicular stabilization ; Rigid screw-plate system ; Comparison with other implants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Das Variable-Screw-Placement-(VSP)-System nach Steffee wurde erstmals 1982 in der orthopädischen Chirurgie angewandt. Diese winkelstabile Platten-Schrauben-Kombination fand in den letzten Jahren auch in der Unfallchirurgie zunehmend Verwendung. In den Jahren 1989 bis 1991 wurden an der Universitätsklinik fur Chirurgie Graz, Department für Unfallchirurgie, 20 Patienten mit diesem Implantat versorgt und das Metall wurde bereits bei 15 dieser Patienten nach durchschnittlich einem Jahr wieder entfernt. Spätresulta-te und vergleichende Ergebnisse mit anderen Implantaten werden vorgestellt.
    Notes: Abstract The variable screw placement (VSP) system was first used in orthopaedic surgery. In recent years, this rigid screw-plate system has been implanted with increasing frequency in patients with traumatic instabilities of the thoracolumbar spine. At the University Hospital in Graz, 20 patients have been operated on in the Department of Surgery using this system, and 15 of them have been followed up some months after the hardware removal. The results are compared with those achieved in patients whose instabilities were stabilized with other implants.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 380 (1995), S. 203-206 
    ISSN: 1435-2451
    Keywords: Magnetic resonance imaging ; Cervical spine ; Titanium implant
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Vorstellung von 10 Patienten, von denen sich 8 Rückenmarkschädigungen und 2 radikuläre Beeinträchtigungen im Rahmen von Dislokationsverletzungen der HWS zuzogen und die nach Stabilisierungsoperationen im Zeitraum von 2 Tagen bis 8 Monaten mittels MRT abgekldrt werden, verfolgt das Ziel, die Einsatz-und Aussagembglichkeiten dieser nicht-invasiven Methode darzustellen. Bei 2 Patienten mit schwerem Schädelhirntrauma konnte die Ursache für die Querschnittsläsion eindeutig einer Rückenmarkschädigung zugeordnet werden. Ebenso korrelierten schwere Binnenschäden des Rückenmarks, wie intramyeläre Hämatome oder Transsektionen, mit kompletten Querschnittsläsionen. Alleinige Rückenmarködeme traten mit einer inkompletten Querschnittsläsion auf. Die Beurteilung des Ruckenmarks nach postoperativer neurologischer Verschlechterung ermöglicht den Ausschluß einer Rückenmarkkompression als Ursache. Die MRT eignet sich auch zur lebenslangen Beurteilung von Rückenmark- und HWS-Veränderungen. Somit kann das Rückenmark mit der postoperativen MRT in Problemfällen und zur Prognoseerstellung herangezogen werden.
    Notes: Abstract We present the cases of ten patients who underwent postoperative magnetic resonance assessment after dislocation injuries of the cervical spine and treatment with anterior interbody fusion and titanium implants. Eight patients had spinal cord injuries and two had nerve root disorders. In two patients who had intracranial haematomas and dislocation fractures of the cervical spine, MRI proved useful for identification of parenchymal spinal cord injuries as the reason for transverse lesions. Severe MR findings of the parenchymal spinal cord injuries (haematoma or transection) correlated with complete transverse lesions (4 patients) and oedema of the spinal cord, with incomplete transverse lesions (3 patients). MR enables us to examine the spinal cord after operations to ensure that correct spinal cord decompression has been achieved (3 patients). MRI is useful for detecting disc protrusion or chronic spinal stenosis in patients with titanium implants. All in all, MRI is an important modality in the evaluation of the posttraumatic cervical spine.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1435-2451
    Keywords: Hyperextension injury ; Lower cervical spine ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Kasuistik beinhaltet 5 Patienten mit Hyperextensionsverletzungen der unteren Halswirbelsäule (HWS). Die dorsale Instabilität in einem Bewegungssegment war im HWS-Röntgen nicht eindeutig zu verifizieren. Die Funktionsaufnahmen zeigten 4mal eine leichte Retrospondylolisthesis von 2 mm and 1mal eine mäßige Erweiterung des Zwischenwirbelraums. Die Mangnetresonanztomographie (MRT) erbrachte bei allen 5 Patienten durch den Nachweis eines ausgeprägten Diskusprolapes, zusätzlich bei 2 Patienten durch die Darstellung eines intramyelären Hämatoms and bei 1 Patienten durch das Auftreten eines Rückenmark(RM)-Ödems, indirekte Hinweise auf ein dorsal instabiles Bewegungssegment.
    Notes: Abstract Five patients with hyperextension injuries and dorsally instable motion segments are presented. In the diagnosis of posterior instabilities plain roentgenograms demonstrated no characteristic signs of an injured cervical spine. Flexion and extension views detected a mild degree (2 mm) of retrospondylolisthesis in four cases and a widened disc space in one case. In all five patients the MR findings that made use suspect a posterior unstable motion segment were disc protrusions; in addition, in two patients these was hemorrhage in the spinal cord and in one patient cord edema.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1435-2451
    Keywords: Lower leg fracture ; Unreamed tibial nail (UTN)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Der unaufgebohrte Tibiamarknagel (UTN) vereinigt die Vorteile des Fixateur externe mit denen des Marknagels in der Behandlung der Unterschenkelfraktur [5]. In der Zeit von März 1992 bis März 1993 wurden 33 Frakturen (31 geschlossene and 2 offene) mit dem UTN stabilisiert. In 67% (22 Patienten) bestanden A1-, A2- and A3-Brüche gemäß der AO-Klassifikation. Sechsmal lag eine Mitbeteiligung des oberen Sprunggelenks vor. 27 Personen konnten durchschnittlich 6 Monate postoperativ nachuntersucht werden; 26 erzielten ein ausgezeichnetes klinisches Ergebnis. Die mittlere Konsolidierungszeit lag bei 12 bis 14 Wochen.
    Notes: Abstract The unreamed tibial nail (UTN) combines the advantages of the external fixator (preservation of the cortical blood supply) with that of conventional intramedullary nailing (closed system, high patient comfort, no pin problems) in the treatment of the lower leg fracture [5]. Within 1 year (III/92 to III/93) 31 closed and 2 open fractures were stabilised with UTN. In 67% (22 persons) we found fractures of the A1, A2 and A3 types according to the AO classification. In 6 patients there was a combined lesion with involvement of the ankle joint. A follow-up of 27 patients was done, extending to an average of 6 months postoperatively. The clinical and radiological results were excellent in 26; average fracture healing time was about 12–14 weeks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...