    Notizen: DDD pacemakers differ considerably in device specific extents of AV delay (AVD) programmability. To demonstrate the requirements of a mean DDD pacemaker patient population optimal AVDs in 200 DDD pacemaker patients (age 8 to 91 years) were estimated by left atrial electrography. The results should help to define an AVD programmability standard. Left atrial electrograms were recorded via a bipolar filtered esophageal lead. The method aims on adjusting the left atrial electrogram to 70 ms prior to the ventricular spike, both during VDD and DDD operation of the pacemaker. In atrial sensed stimulation the optimal AVD varied from 40 to 205 ms (100.5 ± 24.5 ms) and in atrial paced stimulation from 85 to 245 ms (169.1 ±24.5 ms). The difference of the mean values is statistically significant (p 〈 0.001). The difference between both values in the individual patient, the individual AVD correction time, varied from 0 to 170 ms (68.7 ± 26.6 ms). Thus, from our findings requirements on AV delay programmability standard can be derived: AVDs (1) should have a range from 40 to 250 ms, (2) should be independently programmable during atrial sensed and atrial paced operation, ami (3) should provide as nominal settings 100 ms for atrial sensed and 170 ms for atrial paced stimulation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1365-2958
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Biologie , Medizin
    Notizen: We have analysed the capacity of the 11 phase-variable, opacity-associated (Opa) proteins encoded by Neisseria gonorrhoeae MS11 to mediate traversal across polarized monolayers of the human colonic carcinoma T84 cell line. Gonococci expressing either the heparan sulphate proteoglycan (HSPG) binding Opa protein (Opa50) or no Opa protein (Opa−) did not interact with the apical pole of T84 monolayers, whereas the 10 variant Opa proteins previously shown to bind CD66 receptors were found to mediate efficient gonococcal adherence and transepithelial traversal. Consistent with this, T84 cells were shown by reverse transcriptase–polymerase chain reaction (RT–PCR) and immunoblotting to co-express CD66a (BGP), CD66c (NCA) and CD66e (CEA). The recruitment of CD66 receptors by Opa-expressing gonococci indicates their involvement in mediating adherence to the surface of T84 cells, and these bacterial interactions could be inhibited completely using polyclonal antibodies cross-reacting with all of the CD66 proteins co-expressed on T84 cells. Consistent results were obtained when Opa proteins were expressed in Escherichia coli, suggesting that the Opa–CD66 interaction is sufficient to mediate bacterial traversal. Transcytosis of Opa-expressing N. gonorrhoeae or E. coli did not disrupt the barrier function of infected monolayers, as indicated by a sustained transepithelial electrical resistance (TEER) throughout the course of infection, and confocal laser scanning and electron microscopy both suggest a transcellular rather than a paracellular route of traversal across the monolayers. Parallels between the results seen here and previous work done with organ cultures confirm that T84 monolayers provide a valid model for studying neisserial interactions with the mucosal surface, and suggest that CD66 receptors contribute to this process in vivo.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Archives of gynecology and obstetrics 257 (1995), S. 602-606 
    ISSN: 1432-0711
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Herzschrittmachertherapie & Elektrophysiologie 10 (1999), S. S034 
    ISSN: 1435-1544
    Schlagwort(e): Key words Antiarrhythmic therapy – cardiothoracic surgery – atrial fibrillation ; Schlüsselwörter Antiarrhythmische Therapie ; Kardiochirurgie ; Vorhofflimmern
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Hintergrund: Häufigste Arrhythmie im Zusammenhang mit kardiochirurgischen Eingriffen ist das postoperative Vorhofflimmern einschließlich verwandter atrialer Rhythmusstörungen. Da zunehmend ältere Patienten kardiochirurgisch behandelt werden, hat das Interesse an dieser Arrhythmieform mit noch einigen ungeklärten Fragen wieder zugenommen. Ziel und Methode: Darstellung des derzeitigen Kenntnisstandes zum postoperativen Vorhofflimmern unter Berücksichtigung neuerer Literaturmitteilungen. Ergebnisse: In der Regel ist postoperatives Vorhofflimmern vorübergehend, selbstendend und gutartig. Im Falle seines Auftretens sind aber Morbidität, Mortalität und Behandlungskosten höher. Andererseits nimmt das postoperative Vorhofflimmern seinerseits einen ungünstigen Einfluß auf Morbidität und Mortalität. Seine Pathogenese ist multifaktoriell. Eine generelle Prävention kann derzeit nicht empfohlen werden, ist aber in Zukunft denkbar. Die in der Regel nur temporär erforderlichen therapeutischen Überlegungen zu Frequenzkontrolle, Thromboembolieprophylaxe und Rhythmuskontrolle richten sich nach der klinischen Verlaufsform. Schlußfolgerungen: Im Interesse einer Reduktion der Gesamtkomplikationsrate in der Kardiochirurgie bedarf auch das postoperative Vorhofflimmern einer besonderen Aufmerksamkeit.
    Notizen: Background: Atrial fibrillation and related arrhythmias are common after cardiac surgery. As more and more elderly patients are operated on for cardiac diseases, the interest in this arrhythmia is growing again. There are some unresolved problems of this complication. Aims and methods: Reevaluation of atrial fibrillation after cardiac surgery by review of recent literature. Results: Usually postsurgical atrial fibrillation is transient, self-limiting, and benign. Nevertheless, among patients affected by this arrhythmia, morbidity, mortality and costs by hospital stay are higher than without this complication. In addition, postsurgical atrial fibrillation can increase morbidity and mortality by itself. Pathogenesis is multifactorial. Today, general recommendations for prevention of atrial fibrillation following surgery do not exist but may be developed in the future. According to the clinical course, therapy has to consider ventricular rate control, prevention of thromboembolic events, and rhythm control. Usually therapy is restricted to the postoperative time. Conclusions: Atrial fibrillation after cardiothoracic surgery has to be respected in order to minimize overall complication rate.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Der Internist 39 (1998), S. 38-45 
    ISSN: 1432-1289
    Schlagwort(e): Schlüsselwörter Azetylsalizylsäure ; Antikoagulation ; Embolie ; arterielle ; Tachyarrhythmien ; supraventrikuläre ; Vorhofflimmern
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Zum Thema Als begleitende Präventionsmaßnahme im Hinblick auf das Thromboembolie-Risiko hat sich die Antikoagulation neben der medikamentösen antiarrhythmischen Behandlung supraventrikulärer Tachyarrhythmien bewährt. Grundlage dafür sind mehrere seit 1989 publizierte Studien zur Primär- bzw. Sekundärprävention arterieller Embolien bei Vorhofflimmern. Über die Ergebnisse und die daraus abgeleiteten differenzierten Therapieempfehlungen in Abhängigkeit von den klinischen Verlaufsformen supraventrikulärer Tachyarrhythmien wird hier eingehend referiert. Unbestritten ist die prinzipielle Überlegenheit einer oralen Antikoagulation bei supraventrikulären Tachyarrhythmien, besonders beim Vorhofflimmern. Das gilt auch im Vergleich mit der Embolieprophylaxe durch ASS. Nicht außer Betracht bleiben darf aber das mit der Cumaringabe verbundene Blutungsrisiko. Darauf sei ausdrücklich hingewiesen, da dieses in der ambulanten Praxis, also außerhalb von Studienbedingungen, sicher einen anderen Stellenwert hat. Gründe dafür dürften höhere Komorbitität, höheres Lebensalter der Patienten und möglicherweise auch eine weniger exakte Überwachung der Antikoagulation sein.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 0178-515X
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract The recovery of recombinant proteins includes a purification process that has to be compressed to a minimum of steps in order to get high yields with a low cost expenditure. A selective liberation of recombinant proteins by cell permeabilization leads to both a high product purity just in the beginning of the recovery process and to a simplification of the cell residue separation compared to the mechanical cell disruption. In case of the purification of the bacterial plasminogen activator Staphylokinase from E. coli cells, yields of 82% with a purity of 46% were attained by utilization of permeabilization by biomass freezing, resuspension in a Tris/EDTA-buffer and following micro-diafiltration. A recovery process without interruption (freezing) is possible due to the addition of guanidine-HCl and Triton X100 to the buffer. These methods were developed on a laboratory-scale.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1435-1544
    Schlagwort(e): Key words DDD pacing ; AV delay optimization ; Interatrial conduction time ; telemetry ; sense-event marker ; Schlüsselwörter DDD-Stimulation ; AV-Delay-Optimierung ; Interatriale Leitungszeit ; Telemetrie ; Sensing-Marker
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Hintergrund: Bei DDD-Schrittmacherträgern wird das optimale AV-Delay wesentlich durch die interindividuell unterschiedliche interatriale Leitungszeit bestimmt. Wird diese gemessen, kann durch Addition eines bekannten, mittleren, optimalen Intervalles von 70ms zwischen linksatrialer Depolarisation und ventrikulärem Stimulus ein individuell optimales AV-Delay für VDD- und DDD-Betrieb approximiert werden. Da moderne Schrittmacher über eine Telemetrie verfügen, ist es naheliegend, durch Kombination von rechtsatrialer Telemetrie und linksatrialer Elektrographie (via Ösophagusableitung) vorhandene Programmeroptionen zur individuellen AV-Delay-Programmierung zu nutzen. Studienziele: 1. Prüfung der Eignung rechtsatrialer telemetrischer Elektrogramme oder Sensingmarker als rechtsatriale Referenz. 2. Prüfung der Realisierbarkeit einer Implementierung der linksatrialen Elektrographie in handelsübliche Programmer. Methoden: 1. Mittels eines computerisierten Herzsimulators wurde die Verzögerung telemetrischer atrialer Elektrogramme und Sensingmarker bei 12 Schrittmachern 9 unterschiedlicher Hersteller untersucht. 2. Zur Messung interatrialer Leitungszeiten mit Programmiergeräten wurde die Simultandarstellung des rechtsatrialen Elektrogramms bzw. Markerkanals und der linksatrialen Ableitung mittels externer Hardware- bzw. programmerinterner Softwarefilterung der Ösophagusableitung realisiert. Ergebnisse: Abhängig von der Größe des telemetrischen Delays lassen sich Schrittmachersysteme mit Echtzeittelemetrie (Delay 0-12ms) und Orientierungstelemetrie (Delay 12ms) unterscheiden. Es ließ sich zeigen, daß mit der vorgeschlagenen Implementierung linksatrialer Elektrogramme interatriale zeitliche Relationen sowohl unter Vorhofstimulation als auch bei Vorhofführung an Systemen mit Echtzeittelemetrie bequem erfaßt werden können. Die Voraussetzungen für eine individuelle Programmierung des AV-Delay am Programmiergerät und die automatische Bereitstellung von Programmiervorschlägen sowohl für das Basis- als auch des frequenzmodulierten AV-Delay sind damit erfüllt. Schlußfolgerung: Durch Implementierung einer linksatrialen Ableitung in Schrittmacherprogrammer können interatriale Leitungszeiten leicht erfaßt und die physiologische AV-Delay-Programmierung in der Routine vereinfacht werden.
    Notizen: Background: In patients with DDD pacing systems, optimal AV delay is mainly determined by interindividually differing interatrial conduction time. If the latter is measured, individual optimal AV delay in VDD and DDD operation can be approximated by adding a representative, optimal interval of 70ms between left atrial depolarization and ventricular stimulus. In modern pacemakers providing telemetry, combination of right atrial telemetry and left atrial electrography via an esophageal lead could be used to measure interatrial conduction times for individual AV delay programming. Aims of the study: 1. To test the usefulness of telemetric right atrial electrograms and markers as a right atrial measuring reference. 2. To prove the possibility of implementing left atrial electrography into commercial programers. Methods: 1. Using computerized heart simulator, delays of the telemetric electrogram and markers were investigated in 12 DDD systems of 9 different companies. 2. To measure interatrial conduction times with programers, simultaneous recordings of right atrial electrogram and marker channel, resp., and the left atrial electrogram were performed using external hardware or internal software filtering of the esophageal lead. Results: Depending on the range of marker delay, pacing systems with real-time telemetry (delay 0–12ms) and orienting telemetry (delay 12ms) were found. Facilitating left atrial electrogram recording into programers, interatrial time intervals can be measured in DDD and VDD operation in pacing systems with real-time telemetry. These results are prerequisits for individual AV delay programming with the programer. Then both can automatically be proposed, basic AV delay and the frequency modulated AV delay. Conclusion: Facilitating left atrial electrogram recording into pacemaker programers, interatrial conduction times can easily be measured for simplified physiologic AV delay programming during routine check-up.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Herzschrittmachertherapie & Elektrophysiologie 9 (1998), S. S52 
    ISSN: 1435-1544
    Schlagwort(e): Key words Amiodarone ; beta-blockers ; sudden cardiac death ; Schlüsselwörter Amiodarone ; Betablocker ; plötzlicher Herztod
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Hintergrund: Der plötzliche Herztod ist ein Tod überwiegend durch ventrikuläre Tachyarrhythmien. Dennoch deutete sich eine daraus ableitbare Senkung der Gesamtmortalität kardialer Risikofälle durch prophylaktisch verabfolgte Antiarrhythmika, abgesehen vom bekannten Effekt der Betablocker, nur für Amiodarone an. Ziel und Methode: Betrachtung der primären Prophylaxe des plötzlichen Herztodes durch Amiodarone mit und ohne zusätzliche Betablockade unter Berücksichtigung neuerer Literaturmitteilungen. Ergebnisse: Der Beweis einer signifikanten Senkung nicht nur des plötzlichen Herztodes, sondern auch der Gesamtmortalität durch Amiodarone gelang erst in Meta-Analysen kontrolliert durchgeführter Studien. Dessen ungeachtet ist aber die Zahl dadurch verhinderter plötzlicher Tode bezogen auf die Gesamtzahl der zu behandelnden Fälle gering. Dieses und das spezifische Nebenwirkungsprofil stehen einer generellen primären Prophylaxe mit Amiodarone entgegen. Eine Kombination mit einem Betablocker könnte Vorteile bringen, was aber durch weitere Studien noch abgeklärt werden muß. Schlußfolgerungen: Derzeit bleibt die Amiodaronegabe zur Primärprophylaxe des plötzlichen Herztodes mit oder ohne Betablocker eine Einzelfallentscheidung bei besonderer Risikokonstellation, bei der nicht in jedem Fall ein ärztlicher Konsens erwartet werden darf.
    Notizen: Background: Most sudden cardiac deaths are arrhythmic. Besides the known effects of beta-blockers, among true antiarrhythmic drugs only amiodarone seemed to reduce total cardiac mortality in patients at risk. Aim and method: Reevaluation of amiodarone with or without a beta-blocker in primary prophylaxis of sudden cardiac death after review of recent publications. Results: Only augmentation of case numbers by meta-analyses of controlled trials could demonstrate that amiodarone not only reduces sudden cardiac death but also diminishes total cardiac mortality. However, the number of avoided sudden deaths is small in comparison to the number of treated cases. This and specific side effects of amiodarone contradict a general primary prophylaxis with this drug. An additional benefit by combining amiodarone with beta-blockers seems to exist but has to be proven by further studies. Conclusions: At present, primary prophylaxis of sudden cardiac death with amiodarone with or without a beta-blocker is an individual decision in all cases with special risk considerations.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Herzschrittmachertherapie & Elektrophysiologie 11 (2000), S. 59-65 
    ISSN: 1435-1544
    Schlagwort(e): Key words Heart rate variability – 24-h ambulatory Holter ECG –¶recording technology – validation ; Schlüsselwörter Herzfrequenzvariabilität – Langzeit-EKG –¶Holter-Rekorder – Validierung
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung Die überwiegende Anzahl der Untersuchungen zur Herzfrequenzvariabilität (HRV) wurde und wird mit Langzeit-EKG-Technik durchgeführt. Die Option zur HRV-Analyse ist inzwischen in verschiedene kommerziell erhältliche Langzeit-EKG-Systeme (L-EKG-Systeme) implementiert. Grundlegende Voraussetzung aller Methoden der HRV-Analyse ist die zeitlich exakte R-R-Intervallvermessung. Damit erlangt die zur Primärdatenakquisition verwandte Technologie eine Schlüsselstellung. Zur technischen Eignung von Magnetbandrekordern und Festspeicherrekordern hinsichtlich der Genauigkeit der R-R-Intervallakquisition und damit zur Eignung eines Systems zur HRV-Analyse fehlten aber bis dato genaue Aussagen. Aus diesem Grund wurden zunächst im Labor Untersuchungen an kommerziell erhältlichen Langzeit-EKG-Systemen [Ela medical (E), Oxford Medilog Excel (O) und Medset Cardiolight (M)] vorgenommen, mit denen sowohl Magnetbandaufzeichnungen als auch digitale Langzeit-EKG-Aufzeichnungen durchgeführt und ausgewertet werden können. Zur Überprüfung ihrer zeitgenauen Wiedergabe wurden in Parallelregistrierungen die durch ein Computer-Herzmodell vorgegebenen starrfrequenten R-R-Intervalle mit beiden Rekordersystemen erfaßt und ausgewertet. Der Einfluß der Rekordertechnologie auf die Akquisitionsgenauigkeit und damit auf die HRV-Analyse-Ergebnisse konnte anhand der 5 meistverwendeten Parameter der Zeitdomäne belegt werden. Mit den Magnetbandrekordern aller Systeme wurde eine höhere, d.h. technisch bedingte, künstliche R-R-Variabilität erzeugt. Im Vergleich zu den Festspeichersystemen waren die Unterschiede bei allen 3 Systemen hochsignifikant für die Indizes: SDNN (E: 9,38ms vs 2,68ms; p〈0,001; O: 3,89ms vs 0,97ms; p〈0,001; M: 10,47ms vs 2,89ms; p=0,001), SDNN-Index (E: 8,22ms vs 0,90ms; p〈0,001; O: 3,75ms vs 0,90ms; p〈0,001; M: 7,81ms vs 1,49ms, p〈0,001) und RMSSD (E: 10,39ms vs 2,16ms; p〈0,001; O: 10,05ms vs 1,88ms, p〈0,001; M: 8,62ms vs 1,69ms; p〈0,001), im Systemverband Medset zusätzlich für den SDANN-Wert (M: 9,83ms vs 5,37ms; p〈0,001). Mit dem methodischen Vorgehen zur Prüfung der Genauigkeit der R-R-Intervallakquisition wird ein Vorschlag zur Validierung von Langzeit-EKG-Systemen hinsichtlich ihrer Brauchbarkeit für die HRV-Analyse unterbreitet. Die klinische Bedeutung der künstlichen HRV scheint aber nur gering zu sein.
    Notizen: Summary In the past, most scientific or routine studies on heart rate variability (HRV) were done using commercial Holter ECG devices with traditional magnetic tapes. All methods to calculate parameters of HRV are based on the measurement of time intervals between successive sinus cardiac beats, in practice RR intervals. Hence, results of HRV calculation depend on the quality of primary data acquisition. However, technical standards on accuracy of RR interval acquisition in magnetic tape and digital solid state Holter ECG systems do not exist as yet. Therefore in a laboratory investigation accuracy of HRV parameter calculation after traditional standard tape with and without real-time analysis and digital solid state data acquisition was compared in three commercial Holter ECG systems [Ela medical (E), Oxford Medilog Excel (O) and Medset Cardiolight (M)]. A computer-based ECG simulator was used to synthesize a test signal consisting of artificial P-QRS complexes of fixed rate, quartz stabilized „sinus rhythms”. Two channel analog tape and digital 24h recordings of the fixed rate test signal were performed simultaneously. The influence of recording technology on accuracy of RR interval measurement and consequently on time domaine HRV was shown by comparing five standard 24-h time domain parameters. As expected, in the three Holter systems the analog tape recordings showed a higher, technically induced, artificial RR variability. The SDNN values (E: 9.38ms vs 2.68ms; p〈0.001; O: 3.89ms vs 0.97ms; p〈0.001; M: 10.47ms vs 2.89ms; p=0.001), SDNN-Index values (E: 8.22ms vs 0.90ms; p〈0.001; O: 3.75ms vs 0.90ms; p〈0.001; M: 7.81ms vs 1.49ms, p〈0.001) and RMSSD-values (E: 10.39ms vs 2.16ms; p〈0.001; O: 10.05ms vs 1.88ms, p〈0.001; M: 8.62ms vs 1.69ms; p〈0.001) were significantly lower if acquisition was done by digital solid devices in all systems, SDANN (M: 9.83ms vs 5.37ms; p〈0.001) in the Medset system too. The used method is a possible way to validate commercial Holter ECG systems for HRV analysis. Clinical significance of artifical HRV seems to be low.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Herzschrittmachertherapie & Elektrophysiologie 11 (2000), S. 110-116 
    ISSN: 1435-1544
    Schlagwort(e): Key words Heart rate variability – 24-h ambulatory Holter ECG –¶recording technology – validation ; Schlüsselwörter Herzfrequenzvariabilität – Langzeit-EKG –¶Holter-Rekorder – Validierung
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung Hintergrund: In Laboruntersuchungen wurde anhand eines computergenerierten, starrfrequenten EKG-Signals die Überlegenheit der digitalen gegenüber der analogen Aufzeichnungstechnologie in der zeitlichen Akquisitionsgenauigkeit der R-R-Intervalle, als rechnerischer Ausgangsgröße aller Verfahren der HRV-Analyse, belegt. Bandsystemen sind demnach Akquisitionsungenauigkeiten immanent, die eine technisch bedingte, höhere künstliche Variabilität erzeugen.¶   Zielstellung und Methodik: Da die Absolutwerte der künstlichen Variabilität im Vergleich zu den allgemein akzeptierten HRV- Normwerten jedoch vergleichsweise gering ausfallen, sollte die klinische Bedeutung der Ergebnisse aus dem Labor untersucht werden. Dazu wurden analoge Magnetband (A)- und digitale (D) Langzeit-EKG-Rekorder der Firma Ela medical unter Verwendung derselben Elektroden parallelgeschaltet und 24-Stunden-Registrierungen an Patienten mit einer Herzerkrankung und Sinusrhythmus vorgenommen. Unter gleichen Analyse- und Auswertebedingungen lassen sich dann Einflüsse unterschiedlicher Akquisitionsgenauigkeiten über die Differenz zwischen analoger und digitaler Aufzeichungstechnologie für Indizes der Zeit- und der Frequenzdomäne erfassen.¶   Ergebnisse: Die Analyse der Parallelregistrierungen an 20 Patienten ergab bei den gemittelten Werten statistisch signifikante positive Analog-Digital-Differenzen für die Indizes SDNN-Index (A: 38,47ms; D: 36,17ms; p=0,003), RMSSD (A: 25,04ms; D: 21,09ms; p 〈0,001), pNN50 (A: 3,70%; D: 2,40%; p=0,006), Total power (A: 1200,20ms2; D: 1076,55ms2; p=0,032), LF (A: 287,35ms2; D: 243,80ms2; p=0,035), HF (A: 72,50ms2; D: 54,95ms2; p=0,001) sowie signifikant negative A-D-Differenzen für die LF/HF ratio (A: 4,47; D: 5,33; p=0,037). Für SDNN (A: 95,59ms; D: 94,74ms; p=0,29) und SDANN (A: 85,52ms; D: 85,08ms; p=0,68) waren die Unterschiede nicht signifikant.¶   Schlussfolgerungen: Damit ist belegt, dass auch unter klinischen Bedingungen aus Bandregistrierungen künstlich höhere Variabilitäten bestimmt werden. Allerdings muss auch festgestellt werden, dass die Differenzen für die Indizes der Zeitdomäne zwischen Analog- und Digitalregistrierung eher geringer ausfallen als in den Laborversuchen mit computergeneriertem EKG und die Absolutwerte der Differenzen der HRV-Indizes in Relation zur Variationsbreite der Normwerte wenig bedeutsam sind. Somit hat die Wahl der Aufzeichnungstechnologie der Holter-EKG-Systeme für die Bestimmung der HRV im klinischen Alltag nur geringe Bedeutung. Bei der Durchführung von Studien und Betreuung von Hochrisikopatienten ist jedoch die Auswahl der Rekordertechnik kritisch zu überdenken und die digitale Aufzeichnungstechnologie grundsätzlich zu bevorzugen.
    Notizen: Summary The accuracy of the RR interval data acquisition is an essential prerequisite for reliable analysis of heart rate variability (HRV). In previous laboratory investigations, in which computerized electrocardiograms were simultaneously sampled at identical heart rates using digital and analog tape recorders, the superiority of the digital recorders was clearly demonstrated. Conventional tape recordings exhibit technical variability which may produce false positive HRV results. However, the clinical significance of this type of variability is not known.¶   Aim of the study: To characterize the clinical relevance of technical RR variability related to the conventional tape recording process.¶   Methods: In 20 patients with cardiac disease and stable sinus rhythm, 24-hour Holter monitoring was performed by connecting each patient simultaneously to a conventional tape and a digital Holter recorder (Ela medical) via the same leads. Technical variability was defined as the difference between the HRV results obtained by the respective analog (A) and digital (D) recording methods.¶   Results: For the following HRV indices significant A-D differences were found: SDNNindex: 38.47ms (A) vs. 36.17ms, p=0.003; RMSSD: 25.04ms (A) vs. 21.09ms (D), p〈0.001; pNN50: 3.70% (A) vs. 2.40% (D), p=0.006; Total power: 1200.20ms2 (A) vs. 1076.55ms2 (D), p=0.032; LF power: 287.35ms2 (A) vs. 243.80ms2 (D), p=0.035; HF power: 72.50ms2 (A) vs. 54.95ms2 (D); p=0.001, and the LF/HF ratio: 4.47 (A) vs. 5.33 (D), p=0.037. No significant differenes were found for the following indices: SDNN: 95.59ms (A) vs. 94.74ms (D), p=0.29; and SDANN: 85.52ms (A) vs. 85.08ms (D), p=0.68.¶   Conclusions: Under both experimental and clinical conditions, higher HRV values were found in the conventional (tape) recordings. However, the technical variability was small in comparison with the mean values of normal HRV indices and their standard deviation. Thus, differences due to different recorder technology may be neglected in clinical practice. Nevertheless, in scientific HRV trials, it seems wise to use digital Holter recorders.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...