    ISSN: 1432-055X
    Schlagwort(e): Schlüsselwörter Atemarbeit ; Beatmung ; Pressure Support Ventilation ; COPD ; Key words Pressure support ventilation ; Work of breathing ; Chronic obstructive pulmonary disease ; Mechanical ventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Abstract During pressure support ventilation (PSV), the timing of the breathing cycle is mainly controlled by the patient. Therefore, the delivered flow pattern during PSV might be better synchronised with the patient's demands than during volume-assisted ventilation. In several modern ventilators, inspiration is terminated when the inspiratory flow decreases to 25% of the initial peak value. However, this timing algorithm might cause premature inspiration termination if the initial peak flow is high. This could result not only in an increased risk of dyssynchronization between the patient and the ventilator, but also in reduced ventilatory support. On the other hand, a decreased peak flow might inappropriately increase the patient's inspiratory effort. The aim of our study was to evaluate the influence of the variation of the initial peak-flow rate during PSV on respiratory pattern and mechanical work of breathing. Patients. Six patients with chronic obstructive pulmonary disease (COPD) and six patients with no or minor nonobstructive lung pathology (control) were studied during PSV with different inspiratory flow rates by variations of the pressurisation time (Evita I, Drägerwerke, Lübeck, Germany). During the study period all patients were in stable circulatory conditions and in the weaning phase. Method. Patients were studied in a 45° semirecumbent position. Using the medium pressurization time (1 s) during PSV the inspiratory pressure was individually adjusted to obtain a tidal volume of about 8 ml/kg body weight. Thereafter, measurements were performed during five pressurization times (〈0.1, 0.5, 1, 1.5, 2 s defined as T 0.1, T 0.5, T 1, T 1.5 and T 2) in random order, while maintaining the pressure support setting at the ventilator. Between each measurement steady-state was attained. Positive end-exspiratory pressure (PEEP) and FIO2 were maintained at prestudy levels and remained constant during the study period. Informed consent was obtained from each patient or his next of kin. The study protocol was approved by the ethics committee of our medical faculty. Gas flow was measured at the proximal end of the endotracheal tube with a pneumotachometer (Fleisch no. 2, Fleisch, Lausanne, Switzerland) and a differential pressure transducer. Tracheal pressure (Paw) was determined in the same position with a second differential pressure transducer (Dr. Fenyves & Gut, Basel, Switzerland). Esophageal pressure (Pes) was obtained by a nasogastric balloon-catheter (Mallinckrodt, Argyle, NY, USA) connected to a further differential pressure transducer of the same type as described above. The balloon was positioned 2–3 cm above the dome of the diaphragm. The correct balloon position was verified by an occlusion test as described elsewhere. The data were sampled after A/D conversion with a frequency of 20 Hz and processed on an IBM-compatible PC. Software for data collection and processing was self-programmed using a commercially available software program (Asyst 4.0, Asyst Software Technologies, Rochester, NY, USA). Patient's inspiratory work of breathing Wpi (mJ/l) was calculated from Pes/volume plots according to the modified Campbell's diagram. Dynamic intrinsic PEEP (PEEPidyn) was obtained from esophageal pressure tracings relative to airway pressure as the deflection in Pes before the initiation of inspiratory flow Patient's additive work of breathing (Wadd) against ventilator system resistance was calculated directly from Paw/V tracings when Paw was lower than the pressure on the compliance curve. Two-way analysis of variance (ANOVA) was used for statistical analysis, followed by post hoc testing of the least significant difference between means for multiple comparisons. Probability values less than 0.05 were considered as significant. Results. COPD patients had significantly higher pressure support than control patients. With decreasing inspiratory flow, Wpi increased significantly in COPD patients. Additionally, the duct cycle (Ti/Ttot) significantly increased with decreased flow rates which resulted in a higher PEEPidyn compared to the baseline. At T 1.5 and T 2 with lower flow rates, the pre-set pressure support level was not achieved within inspiration in the COPD patients. Wadd increased significantly at T 1, T 1.5 and T 2 in COPD patients and at T 1.5 and T 2 in the control group. In one patient, premature termination of inspiration owing to high initial peak flow was corrected by adjustment of the inspiratory flow. Conclusion. Our results demonstrate that a decreased peak flow during PSV resulted in increased patient's work of breathing in COPD patients. During lower flow, the pre-set pressure support level was not attained and additional work had to be done on the ventilator system. Furthermore, the higher PEEPidyn during lower flow rates indicates a higher risk of dynamic pulmonary hyperinflation in patients with COPD. We conclude that the use of pressurization times ≥1 s to decrease inspiratory peak flow during PSV is of no benefit and should be avoided, particularly in COPD patients. However, in selected cases, slight decrease of inappropriately high peak flows might be useful for optimization of PSV setting to avoid premature termination of inspiration.
    Notizen: Zusammenfassung Bei einigen Respiratoren kann unter Pressure Support Ventilation (PSV) der Inspirationsfluß (V˙ i ) durch Veränderung der Druckanstiegszeit variiert werden. Über den Einfluß des Inspirationsflußprofils unter PSV auf die Atemarbeit ist besonders bei Patienten mit chronischer Atemwegsobstruktion (COPD) kaum etwas bekannt. Wir untersuchten an 6 COPD-Patienten und 6 Patienten ohne Lungenerkrankung (Kontrollgruppe) die Effekte einer Variation von V˙ i unter PSV auf atemmechanische Variablen und die mechanische Atemarbeit. Unter individuell eingestellter Druckunterstützung wurde die Druckanstiegszeit in 5 Stufen verändert. Die Verlängerung der Druckanstiegszeit verminderte den initialen V˙ i in beiden Patientengruppen. Gleichzeitig stieg die Atemarbeit in der COPD-Gruppe bei verringertem V˙ i signifikant an. Eine Ursache hierfür war, daß bei den COPD-Patienten bei langsamen Druckanstiegszeiten die eingestellte Druckunterstützung nicht mehr erreicht wurde. Der langsamere V˙ i führte zu einer Verlängerung der Inspiration auf Kosten der Exspirationszeit. Dies verursachte bei COPD-Patienten eine unerwünschte Erhöhung des intrinsischen PEEP. Die Auswirkungen eines niedrigeren V˙ i unter PSV in der Kontrollgruppe waren klinisch nur wenig relevant. Unsere Ergebnisse zeigen, daß besonders bei Patienten mit COPD unter PSV hohe initiale Inspirationsflüsse zu bevorzugen sind, da ein niedriger Fluß die Patientenatemarbeit erhöht und eine dynamische Lungenüberblähung verstärkt. Allerdings konnte bei einem Patienten ein vorzeitiger Inspirationsabbruch aufgrund eines hohen Initialflusses durch Anpassung des Flußprofils korrigiert werden. In Einzelfällen kann daher eine Verlängerung der Druckanstiegszeit bis auf maximal 1 s sinnvoll sein.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1238
    Schlagwort(e): Key words Aged ; Functional residual capacity ; Lung volume measurement ; Mechanical ventilation ; Critical care ; Chronic obstructive pulmonary disease ; Acute lung injury
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Validation of an open-circuit multibreath nitrogen washout technique (MBNW) for measurement of functional residual capacity (FRC). The accuracy of FRC measurement with and without continuous viscosity correction of mass spectrometer delay time (TD) relative to gas flow signal and the influence of baseline FIO2 was investigated. Design: Laboratory study and measurements in mechanically ventilated patients. Setting: Experimental laboratory and anesthesiological intensive care unit of a university hospital. Patients: 16 postoperative patients with normal pulmonary function (NORM), 8 patients with acute lung injury (ALI) and 6 patients with chronic obstructive pulmonary disease (COPD) were included. Interventions: Change of FIO2 from baseline to 1.0. Measurements and main results: FRC was determined by MBNW using continuous viscosity correction of TD (TDdyn), a constant TD based on the viscosity of a calibration gas mixture (TD0) and a constant TD referring to the mean viscosity between onset and end of MBNW (TDmean). Using TDdyn, the mean deviation between 15 measurements of three different lung model FRCs (FRCmeasured) and absolute volumes (FRCmodel) was 0.2 %. For baseline FIO2 ranging from 0.21 to 0.8, the mean deviation between FRCmeasured and FRCmodel was −0.8 %. However, depending on baseline FIO2, the calculation of FRC using TDmean and TD0 increased the mean deviation between FRCmeasured and FRCmodel to 2–4 % and 8–12 %, respectively. In patients (n = 30) the average repeatability coefficient was 6.0 %. FRC determinations with TDmean and TD0 were 0.8–13.3 % and 4.2–23.9 % (median 2.7 % and 8.7 %) smaller than those calculated with TDdyn. Conclusion: A dynamic viscosity correction of TD improves the accuracy of FRC determinations by MBNW considerably, when gas concentrations are measured in a sidestream. If dynamic TD correction cannot be performed, the use of constant TDmean might be suitable. However, in patient measurements this can cause an FRC underestimation of up to 13 %.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 26 (2000), S. 462-465 
    ISSN: 1432-1238
    Schlagwort(e): Key words Phrenic nerve stimulation ; Work of breathing ; Oesophageal pressure
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Five commercially available oesophageal balloon catheters (OBCs) were tested to evaluate the accuracy in transmitting fast-changing pressure signals which can be observed, for example, during phrenic nerve stimulation.¶Setting: Research laboratory of a university hospital.¶Method: The OBCs tested varied in length (900–1390 mm) and inner diameter (0.9–1.5 mm) as well as in balloon material [latex or polyvinyl-chloride (PVC)]. A 180-cm tube served as a control. A sudden pressure drop was generated by the explosion of a pressurized latex balloon. The time between the pressure drop and 75, 50, 25 and 10 % of the maximal pressure was measured.¶Results: The time intervals required to transduce a pressure drop of 90 % varied between the different OBCs from 85 to 476 ms(control 32 ms). Transmission time was lower in OBCs with a larger inner diameter. Shortening the OBCs resulted in a further decrease in transmission time.¶Conclusion: The type of OBC used has an impact on signal processing. An OBCs with a short transmission time should be chosen, especially if fast pressure changes are to be evaluated such as during phrenic nerve stimulation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-1238
    Schlagwort(e): Work of breathing ; Positive pressure respiration methods ; Lung disease ; Obstructive therapy ; Ventilator weaning ; Mechanical ventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective Evaluation of low-level PEEP (5 cm H2O) and the two different CPAP trigger modes in the Bennett 7200a ventilator (demand-valve and flow-by trigger modes) on inspiratory work of breathing (Wi) during the weaning phase. Design Prospective controlled study. Setting The intensive care unit of a university hospital. Patients Six intubated patients with normal lung function (NL), ventilated because of non-pulmonary trauma or post-operative stay in the ICU, and six patients recovering from acute respiratory failure due to exacerbation of chronic obstructive pulmonary disease (COPD), breathing either FB-CPAP or DV-CPAP with the Bennett 7200a ventilator. Interventions The patients studied were breathing with zero end-expiratory pressure (ZEEP), as well as CPAP of 5 cm H2O (PEEP), with the following respiratory modes: the demand-valve trigger mode, pressure support of 5 cm H2O, and the flow-by trigger mode (base flow of 20 l/min and flow trigger of 2 l/min). Furthermore, Wi during T-piece breathing was evaluated. Measurements and results Wi was determined using a modified Campbell's diagram. Total inspiratory work (Wi), work against flow-resistive resistance (Wires), work against elastic resistance (Wiel), work imposed by the ventilator system (Wimp), dynamic intrinsic positive end-expiratory pressure (PEEPidyn), airway pressure decrease during beginning inspiration (Paw) and spirometric parameters were measured. In the NL group, only minor, clinically irrelevant changes in the measured variables were detected. In the COPD group, in contrast, PEEP reduced Wi and its components Wires and Wiel significantly compared to the corresponding ZEEP settings. This was due mainly to a significant decrease in PEEPidyn when external PEEP was applied. Flow-by imposed less Wi on the COPD patients during PEEP than did demand-valve CPAP. Differences in Wimp between the flow-by and demand-valve trigger models were significant for both groups. However, in relation to Wi these differences were small. Conclusion We conclude that the application of low-level external PEEP benefits COPD patients because it reduces inspiratory work, mainly by lowering the inspiratory threshold represented by PEEPidyn. Differences between the trigger modes of the ventilator used in this study were small and can be compensated for by the application of a small amount of pressure support.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Intensivmedizin und Notfallmedizin 36 (1999), S. S017 
    ISSN: 1435-1420
    Schlagwort(e): Key words Anesthesia – pulmonary complication – COPD – asthma ; Schlüsselwörter Anästhesie – pulmonale Komplikationen – COPD – Asthma
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Zusammenfassung Perioperative pulmonale Komplikationen treten bei Patienten mit vorbestehenden Lungenerkrankungen viel häufiger auf als bei lungengesunden Patienten. Häufigste perioperative respiratorische Komplikationen sind Reduktion der Lungenvolumina, Pneumonie und Bronchospastik. Bei der Identifikation von pulmonalen Risikopatienten stellen Anamnese und klinische Untersuchung die wichtigsten Instrumente dar. Wichtigste pulmonale Risikofaktoren sind chronische Lungenerkrankung, Oberbauch- und Thoraxoperation, Adipositas und Rauchen. Häufigste vorbestehende respiratorische Erkrankungen sind chronisch obstruktive Lungenerkrankungen (COPD und Asthma), während restriktive Lungenerkrankungen eher selten sind. Das Risiko einer pulmonalen Komplikation kann reduziert werden, wenn Genese und Ausprägung der Lungenfunktionsstörung bekannt sind und entweder präoperativ, spätestens aber postoperativ eine adäquate Therapie eingeleitet wird bzw. ein entsprechend geeignetes Anästhesieverfahren und optimale Anästhetika gewählt werden.
    Notizen: Summary Patients with pre-existing respiratory diseases have a significantly higher risk for developing perioperative pulmonary complications than patients with healthy lungs. Most common perioperative respiratory complications are reduction of lung volumes, pneumonia, and bronchospasm, which contribute to increased perioperative morbidity and mortality. Patient's history and clinical examination are the most important measures to identify at-risk patients. Important risk factors for perioperative respiratory complications include chronic respiratory diseases, upper abdominal or thoracic surgery, obesity, and cigarette smoking. Most common pre-existing respiratory diseases are chronic obstructive pulmonary disease (COPD) and asthma whereas restrictive lung diseases play a minor role. The incidence of perioperative pulmonary complications can be decreased if the severity of lung function impairment is identified and sufficient measures are implemented either preoperatively or at least postoperatively. This includes the choice of the adequate anesthesia technique as well as the optimal selection of anesthetics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...