Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 90 (2001), S. 503-505 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Solid-phase reactions of copper films with underlying gadolinium, erbium, and erbium–silicide layers on Si(100) substrates were investigated. For the phase analysis, x-ray diffraction and cross-sectional transmission electron microscopy were used. In the case of Cu/Gd/Si(100), an orthorhombic GdSi2 formed, and, at higher temperatures, copper aggregated into islands. Annealed Cu/Er/Si(100) samples resulted in a hexagonal Er5Si3 phase. In the Cu/ErSi2−x/Si system, the copper catalyzes the transformation of the highly oriented hexagonal ErSi2−x phase into hexagonal Er5Si3. Diverse phase developments of the samples with Gd and Er are based on reactivity differences of the two rare-earth metals. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 63 (1996), S. 481-484 
    ISSN: 1432-0649
    Keywords: 42.10 ; 42.60.E
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The phase and the group velocities are calculated in a three-dimensional neighbourhood of the focus of an aberration-free lens illuminated by a spatially Gaussian beam. The Gouy phase shift caused by the diffraction results in superluminal pulse propagation on the optical axis within the Rayleigh range.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 63 (1996), S. 481-484 
    ISSN: 1432-0649
    Keywords: PACS: 42.10 ; 42.60.E
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract.  The phase and the group velocities are calculated in a three-dimensional neighbourhood of the focus of an aberration-free lens illuminated by a spatially Gaussian beam. The Gouy phase shift caused by the diffraction results in superluminal pulse propagation on the optical axis within the Rayleigh range.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0942-0940
    Keywords: Keywords: Endoscopic third ventriculostomy; occlusive hydrocephalus; pulsatility index; transcranial Doppler-sonography.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Objective . Endoscopic 3rd ventriculostomy has become the method of choice in the management of occlusive hydrocephalus. The treatment is accompanied by significantly less peri-operative complications than the cerebrospinal fluid shunting procedures previously employed. Close surveillance of patients, however, is necessary to avoid the consequences of raised intracranial pressure that may develop in case of obstruction of the artificial outlet of the 3rd ventricle.  The aim of this study was to confirm the value of transcranial Doppler-determined pulsatility index (pI) in the assessment of the patency of endoscopic 3rd ventriculostomy and to elucidate its usefulness in early postoperative recognition of increased intracranial pressure.  Methods. In twenty-two patients suffering from occlusive hydrocephalus, transcranial Doppler sonography (TCD) was performed before, immediately after, and five days after endoscopic fenestration of the floor of the 3rd ventricle. PI was defined with fast Fourier transformation. Mean PI values were determined in both middle cerebral arteries (MCA), over five cardiac cycles.  Results. In nineteen cases, PI values showed a significant decrease immediately as well as five days after the intervention as compared to the pre-operative values, and flow-sensitive MRI confirmed the patency of the fenestration in all cases. In one patient the operation failed to produce an effective diversion of cerebrospinal fluid as shown by flow-sensitive MRI, and the pulsatility index was unchanged. In two patients, a significant immediate postfenestration drop in PI was followed by a recurrence of PI to pre-operative levels without any clinical deterioration.  Conclusions. Preliminary results suggest that the transcranial Doppler-determined pulsatility index is a useful non-invasive tool for the evaluation of the patency of the fenestration in the early follow-up of patients who underwent endoscopic third ventriculostomy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 142 (2000), S. 539-546 
    ISSN: 0942-0940
    Keywords: Keywords: Colloid cyst; endoscopy; biportal technique; radical removal.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary ¶ Four patients harbouring a colloid cyst of the 3rd ventricle were operated on endoscopically. With the “classical” monoportal technique, through a precoronal burr hole only partial removal could be achieved in the first case. As the crucial point of the procedure is the safe dissection of the cyst from the thela chorioidea and from the internal cerebral veins, adequate control of the posterior rim of the foramen of Monro and the roof of the 3rd ventricle is mandatory. Accordingly in other three cases a CT-guided biportal endoscopic technique was applied, which permitted radical removal of the entire cyst with maximum safety. CT-guidance is essential for optimal planning after careful study of the individual anatomy. In this way the rigid scopes are moved exclusively along their own axes throughout the procedure, the resulting brain damage thereby being minimal. With regard to all circumstances of the procedure, the use of flexible endoscopes appears to be inappropriate and biportal endoscopy offers itself as the method of choice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 224-226 
    ISSN: 0173-0835
    Keywords: Preparative affinity electrophoresis ; Gradiflow ; Dextran blue ; Serum proteins ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Using the patented Gradiflow system in conjunction with newly developed affinity membranes, the suitability of an electrokinetic technique for affinity fractionation was investigated. Blue dextran incorporated into an affinity membrane was used to deplete a solution of horse serum of albumin, with the result that a majority of serum proteins were enriched tenfold relative to albumin. The technique, when fully developed, would offer some advantages over affinity chromatography, since to a degree it is possible to control which components of the sample are presented to the affinity matrix. Furthermore, the technique would extend the capabilities of the already multifunctional Gradiflow system.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 16 (1995), S. 98-100 
    ISSN: 0173-0835
    Keywords: Preparative electrophoresis ; Membranes ; Serum albumin ; Reflux electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: As part of the method for large-scale preparative electrophoresis across membranes of controlled porosity, we show that successive amounts of the leading component of a mixture migrating across a thin membrane can be collected by ‘reflux electrophoresis’. This consists of a series of cycles, in each of which the forward phase is stopped before the trailing components can emerge, the leading fraction is collected and the membrane cleared by reversing the current before commencing the next cycle. The reflux principle is demonstrated by separations based on size or on charge differences of protein molecules.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...