Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The improvement of potential confinement was attained in the GAMMA 10 tandem mirror [Phys. Rev. Lett. 55, 939 (1985); Proceedings of the 13th International Conference on Plasma Physics and Controlled Nuclear Fusion Research, Washington, 1990 (International Atomic Energy Agency, Vienna, 1991), Vol. 2, p. 539] by axisymmetrization of heating systems for the plasma production, heating, and potential formation. A significant increase of the density and diamagnetism by the potential confinement was observed. In the previous experiment, it was difficult to increase the central cell density higher than 2.7×1018 m−3. One of the possible mechanisms is the density clamping due to the eigenmode formation of the ion–cyclotron-range of frequency (ICRF) waves in the axial direction. With high harmonic ICRF waves (RF3), the experiments to overcome this problem have been performed. In preliminary experiments with RF3 and NBI the maximum density of 4×1018 m−3 was attained. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Neutron diagnostics are applied to a deuterium plasma mixed with protons in the central cell of the GAMMA 10 tandem mirror [Inutake et al., Phys. Rev. Lett. 55, 939 (1985)]. The deuterium ions are heated with a slow ion cyclotron wave tuned to the fundamental deuterium resonance near the mid-plane of the central cell while the plasma is sustained with the fundamental resonance heating of protons in the minimum-B anchor cells. The measurement is based on in situ calibration to determine the transmission efficiency through machine walls and the counting efficiency of the detection system for neutrons emitted from 252Cf with energy close to that in the deuterium–deuterium (D–D) fusion reaction. The observation shows that the count rate of neutrons increases with diamagnetism, and this relation is accounted for in terms of fusion reaction between deuterium ions with a transverse temperature exceeding 10 keV. Discrepancies among ion temperatures determined with different diagnostics are mostly attributed to insufficient knowledge of the profiles of plasma parameters. The results indicate that the neutron measurement can be added as a powerful diagnostic tool for hot ions if combined with more detailed profile measurements. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Semiconductor ion detectors are developed and characterized for the purpose of the use for high-output and wide-energy-sensitive upgraded ion diagnostics. In particular, the theoretical basis for the simulation of the semiconductor ion-energy response along with its experimental verification using monoenergetic ion beams is investigated. High-output-current semiconductor signals ranging from one to three orders of magnitude larger than those from widely employed commercially available silicon-surface-barrier detectors are attained in the ion-energy region above 0.2 keV. These data are found to be well fitted by the developed simulation results. In order to observe ion signals alone under the complicated condition of the simultaneous incidence of ions, electrons, and x rays, we develop an upgraded electrostatic ion-energy spectrometer, having specific structures with obliquely positioned multiple grids. The combination of the installation of such a low-ion-energy-sensitive semiconductor detector and this novel-structured ion spectrometer provides a new electrostatic large-output and low-energy-sensitive ion spectrometer having no signal disturbances from the other plasma species and giving no perturbations to ambient plasma-confining magnetic fields. Accordingly, this novel compact-sized electrostatic ion spectrometer using a single-channel semiconductor collector provides temporal-evolution data on ion-energy spectra during a single plasma shot alone; therefore, this spectrometer is usefully applicable to the opportunities of the observations of ion parameters in both divertor and hot-core regions. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the purpose of plasma-ion-energy analyses in a wide-energy range from a few hundred eV to hundreds of keV, upgraded semiconductor detectors are newly fabricated and characterized using a test-ion-beam line from 0.3 to 12 keV. In particular, the detectable lowest-ion energy is drastically improved at least down to 0.3 keV; this energy is one to two orders-of-magnitude better than those for commercially available Si-surface-barrier diodes employed for previous plasma-ion diagnostics. A signal-to-noise ratio of two to three orders-of-magnitude better than that for usual metal-collector detectors is demonstrated for the compact-sized semiconductor along with the availability of the use under conditions of a good vacuum and a strong-magnetic field. Such characteristics are achieved due to the improving methods of the optimization of the thicknesses of a Si dead layer and a SiO2 layer, as well as the nitrogen-doping technique near the depletion layer along with minimizing impurity concentrations in Si. Such an upgraded capability of an extremely low-energy-ion detection with the low-noise characteristics enlarges research regimes of plasma-ion behavior using semiconductor detectors not only in the divertor regions of tokamaks but in wider spectra of open-field plasma devices including tandem mirrors. An application of the semiconductor ion detector for plasma-ion diagnostics is demonstrated in a specially designed ion-spectrometer structure. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 4928-4936 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A novel end-loss ion-energy spectrometer is designed for plasma-ion diagnostics in open-ended plasma-confinement devices. This analyzer significantly upgrades a previous slanted grid end-loss analyzer (SELA) to essentially eliminate secondary-electron current, and to provide a differential-spectrum mode of operation, in addition to the usual integral-spectrum operation of gridded ion-energy analyzers. The upgraded SELA does not perturb the ambient magnetic field due to its electrostatic operation. Either the differential or integral spectra are obtained by a time sweep of grid voltages, collecting the ion current on a single-channel plate. Because the angular alignment of the SELA is not critical, it can be used as a spatially scannable diagnostic of ion-energy distributions and plasma potentials. It is characterized using computer simulations of ion trajectories, monoenergetic ion beams, and end-loss plasma from the world's largest tandem mirror—GAMMA 10. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A charge exchange neutral particle analyzer including a newly designed multichannel 63.6° cylindrical electrostatic energy analyzer was constructed. Since the energy analyzer can simultaneously adopt a small radius of cylindrical electrodes and a large width of an entrance slit, high incident current can be analyzed while the size of the analyzer remain compact. Characteristics of the analyzer were investigated using hydrogen beam with energies from about 0.5 to 5 keV. The experimental results are compared well with the numerical analysis. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of metamorphic geology 13 (1995), S. 0 
    ISSN: 1525-1314
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences
    Notes: Abstract Aqueous fluid released in metamorphism is transported upwards from depth to the Earth's surface. I propose a hydrofracturing model for the fluid transport. In the model, fluid is transported by the upward propagation of a two-dimensional vertical fluid-filled crack from a fluid reservoir (e.g. overpressured compartment under a seal) at depth to the Earth's surface; fluid is injected consecutively from the reservoir into the crack at a given (but not necessarily constant) injection rate; some of the injected fluid is lost by infiltration from the crack walls into the surrounding permeable rock. An approximate solution of the crack propagation is obtained using fluid dynamics for turbulent film flow and linear elastic fracture mechanics. The solution shows the transition from a regime in which the excess pressure of the fluid in the reservoir drives the propagation to a regime in which the buoyancy of the fluid in the crack drives the propagation. For example, if the net injection rate of H2O is 1 m2/s, the regime transition occurs when the vertical crack length becomes 280 m; after the transition, the propagation velocity and average aperture are constant: 21 m/s and 4.8 cm. If the injection rate is lower than a critical value, hydrofracturing cannot be an effective mode for the fluid transport because of the significant fluid loss by infiltration from the crack walls into the surrounding permeable rock. Assuming a fluid-saturated crust with hydrostatic pore fluid pressure, a lower limit can be estimated for the injection rate required to transport H2O by hydrofracturing without significant fluid loss. For example, the lower limit for transport from a depth of 15 km to the Earth's surface is estimated at 0.2 m2/s if the crustal permeability is 10-17 m2. The lower limit decreases with decreasing crustal permeability.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In the GAMMA 10 tandem mirror, ion cyclotron range of frequency heating has been used effectively in the central cell. The ion temperature becomes several keV and an ion beta value is a few %. Semiconductor detectors are used for measurement of high energy protons in both parallel and perpendicular directions to the magnetic field line. Observed pitch angle distribution peaks near the cyclotron resonance layer and estimated pressure profile in the axial direction is consistent with the profile from a diamagnetic loop array. Strong temperature anisotropy can drive an Alfvén ion cyclotron (AIC) mode unstable. In a typical discharge, the temporal evolution of the endloss high energy ions has strong correlation with that of the AIC-mode amplitude. The enhancement of the loss of high energy ions due to the AIC mode is suggested. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Charge-exchange (C–X) neutral particle measurements have been carried out in hot-ion-mode plasmas of the GAMMA 10 tandem mirror. In the present experiment, a microwave power of 40 kW in 28 GHz is injected toward a second harmonic ECR layer located in the vicinity of the ICR layer at the central region and the radial profiles of ion temperatures determined from the energy spectrum of the C–X neutrals by using a neutral particle energy analyzer (NPA) are investigated from the viewpoint of ion energy balance. At the onset of the ECRH pulse, a remarkable increase of C–X neutral flux with high energy (few keV to few tens keV) is observed with NPA and the resultant ion temperature on the plasma axis is found to increase from 2.5 to 5.0 keV at the electron line density of 3×1013 cm−2. Based on the measured plasma parameters, radial profiles of ion-energy losses due to classical processes are evaluated and ECRH in the central region is confirmed to reduce the energy loss due to electron drag significantly in the core-plasma region. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: An idea for using semiconductor detectors to simultaneously observe both plasma ion Ti and electron Te temperatures is proposed. The idea is also experimentally verified in tandem-mirror plasma shots. This method is developed on the basis of an alternative "positive" use of a semiconductor "dead layer" as an energy-analysis filter. Filtering dependence of charge-exchange neutral particles from plasmas on the thickness of a thin (on the order of nm thick) SiO2 layer is employed for analyzing Ti in the range from hundreds to thousands of eV. Even under the conditions of simultaneous incidence of such particles and x rays into semiconductor detectors, the different dependence on their penetration lengths and deposition depths in semiconductor materials makes it possible to distinguish particles (for Ti) from x rays (for Te). In this letter, proof-of-principle plasma experiments for the proposed idea are carried out to verify the availability of this concept of distinguishing and identifying each value of Ti and Te by the use of various thin filtering materials prior to the use of thinner dead layers. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...