Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 215 (1981), S. 171-180 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Trabecular meshwork and iris were studied by light and electron microscopy in a 40-year-old female with pigmentary glaucoma. Elevation of the intraocular pressure was most likely due to closure the intertrabecular space by pigment granules and large cells resembling clump cells, fibrous substances, and hypertrophied endothelial cells of the trabecular sheet, which had phagocytized pigment granules.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    International journal of thermophysics 21 (2000), S. 1463-1471 
    ISSN: 1572-9567
    Keywords: density ; molten state ; pycnometer ; semiconductor ; silicon
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The density of molten silicon was measured using a newly developed pycnometer made of boron nitride. The present method has many advantages for measuring the density of molten silicon, which has a high temperature and can be easily oxidized. The pycnometer was precisely machined, and its volume at high temperatures was acculately determined. The procedure to overflow the excess melt was carried out in a closed apparatus under a helium atmosphere. A special procedure was introduced to avoid the error generated by the volume expansion of silicon when it solidified. The total uncertainty of the measurement was estimated to be within 0.5%. The measured density showed a linear relationship with respect to temperature and agreed well with literature values. The expansion coefficient of molten silicon was similar to those of typical molten metals in spite of the low expansion coefficient of solid silicon. This suggested that the structural change of molten silicon was similar to those of typical metals.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1741-0444
    Keywords: Exercise testing ; Exponential work rate forcing ; VO2-kinetics ; First-order dynamics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A new exercise protocol has been proposed, with respect to cardiopulmonary exercise testing, which starts at a low work rate (WR) and increases exponentially by a standard percentage of the previous work rate every minute: the test is termed STEEP (standardised exponential exercise protocol). The potential advantage of this protocol is that it can accommodate a wide range of subjects, since it allows a maximum to be attained with a relatively narrow variation of tolerance time, regardless of subjects exercise capacity. To date, only the VO 2max has been compared with that from the current standard ramp protocol. The ramp, however, also allows other important parameters of aerobic function to be estimated: the anaerobic threshold (AT); the response time constant; and ΔVO2/ΔWR. The aim of this study was, therefore, to clarify whether these aerobic parameters can be readily discerned from the responses to the STEEP protocol both from a theoretical and practical viewpoint. As a result of theoretical considerations, we demonstrated that the VO2 time constant and ΔVO2/ΔWR may not both be estimated uniquely. As a practical expedient, a procedure was proposed for estimating the parameter analogues. The preliminary results for six subjects between the STEEP and ramp protocols showed consistent positive correlation for VO 2max (r=0.997) and AT-VO2 (r=0.980), whereas the correlation for the VO2 time constant and ΔVO2/ΔWR were not significant. Further study is needed to clarify the reason(s) for the discrepancies both from a theoretical and practical viewpoint.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...