Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1617-4623
    Keywords: Key words Taka-amylase A gene ; Aspergillus nidulans ; Gene regulation ; Nuclear factor ; Cis-acting element
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The Taka-amylase A gene (taaG2) of Aspergillus oryzae is inducibly expressed in A. nidulans upon exposure to inducing carbon sources, such as starch and maltose. In order to identify nuclear factor(s) possibly involved in the induction of the taaG2 gene, gel mobility shift assays and DNase I footprinting analyses were carried out, and revealed a novel nuclear factor in A. nidulans extracts, which specifically bound to two sites in the taaG2 promoter region, −204 to −189 and −182 to −168, which share the common sequence GGAAATT. The nuclear factor was detected in nuclei from both induced and uninduced mycelia. Mutational analysis within and around the binding sequences demonstrated that only the upstream binding sequence, designated SRE (starch responsive element), was required for the inducible expression of the taaG2 gene, and thus we designated the nuclear factor SREB (SRE binding factor). The downstream binding site contained an inverted SRE (ISRE) and played no role in the induction of taaG2 expression. SREB was shown by gel retardation assays to have higher affinity for SRE than for ISRE.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-232X
    Keywords: Key words Sialidosis ; Lysosomal neuraminidase ; Homology modeling ; Protective protein / cathepsin A
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract To gain insight into the pathogenesis of sialidosis type 1, we performed molecular investigations of two unrelated Japanese patients. Both of them are compound heterozygotes for base substitutions of 649G-to-A and 727G-to-A, which result in amino acid alterations V217M and G243R, respectively. Using homology modeling, the structure of human lysosomal neuraminidase was constructed and the structural changes caused by these missense mutations were deduced. The predicted change due to V217M was smaller than that caused by G243R, the latter resulting in a drastic, widespread alteration. The overexpressed gene products containing these mutations had the same molecular weight as that of the wild type, although the amounts of the products were moderately decreased. A biochemical study demonstrated that the expressed neuraminidase containing a V217M mutation was partly transported to lysosomes and showed residual enzyme activity, although a G243R mutant was retained in the endoplasmic reticulum/Golgi area and had completely lost the enzyme activity. Considering the data, we surmise that the V217M substitution may be closely associated with the phenotype of sialidosis type 1 with a late onset and moderate clinical course.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 38 (2000), S. 569-574 
    ISSN: 1741-0444
    Keywords: Photoplethysmogram ; Pulse arrival time ; Systolic blood pressure ; Noninvasive measurement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A continuous noninvasive method of systolic blood pressure estimation is described. Systolic blood pressure is estimated by combining two separately obtained components: a higher frequency component obtained by extracting a specific frequency band of pulse arrival time and a lower frequency component obtained from the intermittently acquired systolic blood pressure measurements with an auscultatory or oscillometric system. The pulse arrival time was determined by the time interval from QRS apex in electrocardiogram to the onset of photoplethysmogram in a fingertip beat-by-beat via an oximetric sensor. The method was examined in 20 patients during cardiovascular surgery. The estimated values of systolic blood pressure were compared with those measured invasively using a radial arterial catheter. The results showed that the correlation coefficients between estimated values and invasively obtained systolic blood pressure reached 0.97±0.02 (mean±SD), and the error remained within ±10% in 97.8% of the monitoring period. By using a system with automatic cuff inflation and deflation to acquire intermittent systolic blood pressure values, this method can be applicable for the continuous noninvasive monitoring of systolic blood pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...