Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 87 (2000), S. 3137-3142 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A series of samples was deposited by very high frequency glow discharge in a plasma of silane diluted in hydrogen in concentrations SiH4/(SiH4+H2) varying from 100% to 1.25%. For silane concentrations below 8.4%, a phase transition between amorphous and microcrystalline silicon occurs. Microcrystalline silicon has been characterized by transmission electron microscopy (TEM) and x-ray diffraction. The medium-resolution TEM observations show that below the transition, the microstructure of microcrystalline silicon varies in a complex way, showing a large variety of different growth structures. For the sample close to the phase transition, one observes elongated nanocrystals of silicon embedded in an amorphous matrix followed at intermediate dilution by dendritic growth, and, finally, at very high dilution level, one observes columnar growth. X-ray diffraction data evidence a (220) crystallographic texture; the comparison of the grain sizes as evaluated from TEM observations and those determined using Scherrer's equation illustrates the known limitations of the latter method for grain size determination in complex microstructures. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of sensory studies 17 (2002), S. 0 
    ISSN: 1745-459X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: We tested the hypothesis that exposure to an aroma through a food or beverage in the first part of a meal (preload) would reduce the consumption of a food with the same aroma in the second portion of the meal, because of olfactory-specific satiety. In a first experiment, 35 young, normal-weight adults participated in 2 lunch sessions during which they consumed a fixed preload of either ranch-flavored or plain potato chips and sparkling water, followed by ad libitum consumption of a pasta salad with ranch dressing and sparkling water. In the second experiment, 33 subjects consumed a fixed preload of either lemon-flavored or plain sparkling water and pasta salad with ranch dressing, followed by ad libitum consumption of lemon-flavored yogurt and plain sparkling water. No difference was observed in the amount of food consumed (corrected for session order effects) as a function of prior exposure to ranch flavor in the chips or lemon flavor in the water. We conclude that exposure to a preload aroma may not have a significant effect on subsequent intake of a food with the same aroma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 259-262 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Laser-based cavity ringdown techniques have demonstrated ultrahigh sensitivities for trace gas detection in the optical and infrared wavelength regions. We have investigated the applicability of the cavity ringdown technique in the millimeter wave region, which is rich in the rotational spectra of molecules. The millimeter-wave system uses a tunable Fabry–Perot cavity that is excited by a continuous-wave, phase-locked source at the W band; a fast PIN diode switch that turns off the excitation after the cavity is tuned to resonance; and a diode detector that records the resonance decay. Proof of concept has been established by measuring the ringdown times with absorbing materials in the cavity and comparing them with theoretical prediction. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    Berlin : Periodicals Archive Online (PAO)
    Orientalistische Literaturzeitung. 60:1/2 (1965:Jan./Feb.) 70 
    ISSN: 0030-5383
    Topics: Linguistics and Literary Studies , Ethnic Sciences , History
    Notes: Besprechungen
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Commentarii mathematici Helvetici 75 (2000), S. 171-188 
    ISSN: 1420-8946
    Keywords: Key words. Connectivity at infinity, Artin groups, duality groups.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Abstract. Given an improper action (= cell stabilizers are infinite) of a group G on a CW-complex $ {\cal X} $ , we present criteria, based on connectivity at infinity properties of the cell stabilizers under the action of G that imply connectivity at infinity properties for G. A refinement of this idea yields information on the topology at infinity of Artin groups, and it gives significant progress on the question of which Artin groups are duality groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary During blood circulation statistically significant alterations of clotting factor activities, thrombin time and fibrin polymerization time are observed. In relation to the blood from the right heart the activity of factor VIII increases with each passage of a capillary system. Prothrombin and factor X on the other hand show a decrease in activity. Thrombin time and fibrin polymerization time become longer. All these changes are obviously fully reversible by a passage through the liver. Thrombocyte counts behave differently. They are highest in the vena cava (blood from the bone marrow). The most marked changes of all parameters are seen in the renal venous blood.
    Notes: Zusammenfassung Bei der Kreislaufpassage des Blutes kommt es zu statistisch signifikanten Veränderungen der Aktivitäten von Gerinnungsfaktoren, der Thrombinzeit und der Fibrinpolymerisationszeit. Ausgehend vom Mischblut des rechten Herzens nimmt der Faktor VIII bei Passage eines jeden Capillargebietes an Aktivität zu. Prothrombin und Faktor X nehmen dagegen an Aktivität ab. Thrombinzeit und Fibrinpolymerisationszeit werden länger. Alle diese Veränderungen kehren sich offensichtlich bei der Leberpassage wieder um. Die Thrombocytenzahlen verhalten sich anders. Sie sind in der Vena cava am höchsten (Blut aus dem Knochenmark). Für alle Parameter finden sich die stärksten Veränderungen im Nierenvenenblut.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Experimental mechanics 9 (1969), S. 215-219 
    ISSN: 1741-2765
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract An ultrasonic method was developed for making approximate measurements of the thickness of a web moving between parallel guides. Since practical considerations ruled out mechanical contact, a phasesensitive detection scheme for measuring the thickness of the air spaces between the fixed guides and the web was chosen so that: (1) the apparatus was insensitive to variations in surface properties of the web, and (2) a linear response was closely approximated. Unwanted reflections and their influence were reduced through the design of the acoustical geometry and a dummy arrangement. Another set of dummies compensated for changes in sound velocity with temperature changes. Performance curves of the ultrasonic measuring device show that the device performs satisfactorily if all electrical-to-sonic transducers have identical temperature vs. phase-lag characteristics at the operating frequency.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim [u.a.] : Wiley-Blackwell
    Materials and Corrosion/Werkstoffe und Korrosion 19 (1968), S. 25-35 
    ISSN: 0947-5117
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Description / Table of Contents: Cathodic protection potential at defective points in the pipe covering and at pit corrosion zonesCathodic corrosion protection of effectively wrapped pipelines requires low mean current densities only. In principle, Cathodic protection is also practicable for major defective zones. However, the different ohmic voltage drops in front of the metal surface to be protected will at first give rise, in the soil, to a non-homogeneous distribution of the potential which will gradually become homogeneous in the Course of time. With cathodic protection, secondary cover layers containing carbonate are formed at the phase boundary between metal and electrolyte, which result in a decrease in current density.After a short time, the cathodic protection potential can also be detected at the bottom of pit corrosion zones. Normally, the voltage drop between edge and bottom of the pit is small. Following a current failure in a pipeline that has been cathodically protected for years, the pipe/soil potential remains with the cathodic protection range for several days. With intermittent protection current, the corrosion rate is lower than without cathodic protection.
    Notes: Der kathodische Korrosionsschutz gut umhüllter Rohrleitungen erfordert nur geringe mittlere Schutzstromdichten. Auch an größeren Fehlstellen der Rohrumhüllung ist grundsätzlich ein kathodischer Schutz möglich. Vor der zu schützenden Metalloberfläche tritt jedoch zunächst durch unterschiedliche Ohm'sche Spannungsabfälle im Erdboden eine inhomogene Potentialverteilung auf, die sich im Laufe der Zeit ausgleicht. Beim kathodischen Schutz werden an der Phasengrenze Metall/Elektrolyt sekundär carbonathaltige Deckschichten gebildet, die zu einer Verringerung der Stromdichte führen.Das kathodische Schutzpotential ist nach kurzer Zeit auch am Lochboden von Korrosionsanfressungen nachweisbar. Der Spannungsabfall zwischen Lochrand und Lochboden ist normalerweise gering. Beim Stromausfall einer jahrelang kathodisch geschützten Rohrleitung bleibt das Rohd Boden-Potential noch tagelang im kathodischen Schutzbereich. Bei intermittierendem Schutzstrom ist die Korrosionsgeschwindigkeit kleiner als ohne kathodischen Schutz.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 237 (1968), S. 104-110 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine einfache Methode beschrieben, um mit Hilfe eines handelsüblichen coulometrischen Hygrometers Wassermengen von 10–350 μg in Trockenampullen zuverlässig zu bestimmen.
    Notes: Summary A simple method is described for the reliable determination of 10 to 350 μg of water in lyophilised ampoules by means of a commercially available coulometric hygrometer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 239 (1968), S. 289-294 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die bis vor kurzem in der Handhabung und Auswertung eher umständliche coulometrische Titration ist durch den Einsatz von modernen Coulometern (mit digitaler Anzeige in μVal) so weit vereinfacht worden, daß sie mit konventionellen Titrationsverfahren konkurrenzfähig geworden ist. Die der coulometrischen Titration eigenen Vorteile werden besprochen, und die Einsatzmöglichkeiten werden anhand einer Reihe von Beispielen aus der organischen und anorganischen Chemie beleuchtet.
    Notes: Abstract Coulometers of recent design (with digital indication in μeq.) have simplified coulometric titrations to the point where they compare favourably with conventional titrations. The inherent advantages of coulometry are discussed and applications to organic and inorganic compounds are reported.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...