Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (1)
  • 1985-1989  (3)
  • Chemistry  (3)
  • Erythropoietin  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 66 (1988), S. 241-245 
    ISSN: 1432-1440
    Keywords: Erythropoietin ; Stability ; Radioimmunoassay ; Polycythemic mouse bioassay ; Recombinant DNA
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Radioimmunoassays for erythropoietin are limited so far to a few specialized laboratories and this requires transport and storage of samples. We therefore tested the stability of immunoreactive erythropoietin in serum and plasma samples obtained from a uremic and a nonuremic anemic patient. No significant change in the concentration of immunoreactive erythropoietin was found in either serum or plasma samples for up to 14 days of storage. This type of stability was observed no matter whether the samples were stored at room temperature, 4° C, or −20° C. There was no difference between the estimates of erythropoietin in serum and heparinized plasma. Validity of the radioimmunoassay used in this study was demonstrated by parallelism of dilution curves of test specimens and the 2nd International Reference Preparation for erythropoietin and by a close correlation between the immunoreactivity and the bioactivity of the hormone, as assessed in the same samples by the exhypoxic polycythemic mouse bioassay. In conclusion the data obtained clearly indicate that the necessity of storage and transport of clinical samples does not limit the practicability of the radioimmunoassay for erythropoietin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 70 (1998), S. 1108-1108 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1107-1110 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The Poisson's ratios of polyamic acid and polyimide films were determined using a high pressure gas dilatometer. In this technique, a sample is held at constant length and a hydrostatic pressure is applied to the sample. The resulting change in stress on the sample with applied pressure provides a measure of Poisson's ratio. For fully cured polyimide films based on pyromellitic dianhydride and oxydianiline, Poisson's ratio was measured to be 0.34 at approximately 1% strain. This value increases to 0.48 as the strain is increased to 5%.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1611-1613 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Using an energy balance approach incorporating a Flory-Huggins expression for free energy and the strain energy of the material, the solvent removal process in liquid-based coatings was shown to depend on stress and temperature. An equilibrium is obtained between residual solvent content and stress in the coating at a given temperature. Such stress-dependent solvent removal behavior was observed with a polyamic acid coating solution-cast using N-methylpyrrolidinone.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...