ISSN:
1432-1114
Source:
Springer Online Journal Archives 1860-2000
Topics:
Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
Notes:
Abstract Research and development work carried out to provide a method to measure accurately instantaneous flow rates in periodically operating injection systems is summarized. The instantaneous flow rate is reconstructed from axial velocity time series measured by a laser Doppler anemometer on the center-line of a capilary pipe flow. The theoretical background, on which the evaluation of the instantaneous flow rate is based is provided. It is shown that the axial mean velocity is sufficient to reconstruct the periodically varying flow rate and the pressure gradient. The application of the proposed method is described and an instrument is suggested that can be employed in many fields where fast, periodically varying flow rates occur and instantaneous information is needed.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00190273
Permalink