Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A rat bone marrow cell culture was used to evaluate the osteogenic potential of amorphous and crystalline thin calcium phosphate (Ca/P) coatings. The coatings were deposited on titanium discs using a radiofrequency magnetron sputter procedure. Amorphous and crystalline plasma spray Ca/P coated and noncoated titanium discs served as reference material. The cellular behavior was analyzed with quantitative (attachment and proliferation rates) and qualitative (scanning electron microscopy) techniques. No significant differences were found in cell attachment and proliferation rates between the various materials. Scanning electron microscopy showed extracellular matrix formation after 18 days of culture on amorphous plasma-sprayed and the two types of magnetron sputtered coatings. Furthermore, no severe degradation of the magnetron sputtered coatings was observed. They even appeared to induce apatite formation. On basis of the results, we conclude that magnetron sputtering appears to be a promising method to manufacture bioactive ceramic coatings. © 1995 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 539-547 
    ISSN: 0021-9304
    Keywords: in vivo ; soft-tissue reaction ; scanning electron microscopy ; confocal laser scanning microscopy ; three-dimensional reconstruction ; implant interface ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 μm. All grooves had a depth of approximately 0.5 μm. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast, LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 μm grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 539-547, 1997.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 37 (1997), S. 60-67 
    ISSN: 0021-9304
    Keywords: heat treatment ; calcium phosphate ; coating ; sputter ; implant ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study evaluated the effect of rapid heating with infrared radiation on the physico-chemical and morphological properties of radio frequent (RF) magnetron-sputtered calcium phosphate (Ca-P) coatings. About 2.5 μm thick Ca-P coatings were deposited on titanium disks and cylinders. These specimens were left untreated or were heat treated by infrared radiation at 300, 400, 500, 600, and 700°C for 4, 7, 11, 17, and 24 s. Subsequently, the specimens were immersed in simulated body fluid (SBF) for 1 day, 1 week, and 5 weeks. X-ray diffraction measurements showed that heating at 500°C or higher resulted in an increase of coating crystallinity. In addition, FT-IR measurements revealed the appearance of OH peaks in the spectra of samples treated at 500-700°C. Electron probe microanalysis showed that after 5 weeks of immersion about 40-50% of the coatings heat treated at 500 and 600°C was maintained. The coatings heat treated at 700°C showed no dissolution at all. On the other hand, as-coated and 300°C treated films were dissolved within 1 day. Scanning electron microscopy of the samples showed that directly after heat treatment no apparent cracks were present in the coatings. On the basis of these findings, we conclude that rapid heating with infrared radiation around 600°C is the best heat treatment for RF magnetron-sputtered coatings. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 60-67, 1997.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: surface topography ; plasma etching ; cellular orientation ; focal adhesion point ; in vitro ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During this study, microtechnology and plasma etching were used to produce gratings 1.0 (TiD01), 2.0 (TiD02), 5.0 (TiD05), and 10.0 μm wide (TiD10) into commercially pure titanium wafers. After incubation of rat dermal fibroblast (RDFs) on these surfaces for 3 days, the cells were observed with scanning electron (SEM), transmission electron (TEM), and confocal laser scanning microscopy (CLSM). Results showed that the RDFs as a whole and their stress fibers oriented strictly parallel to the surface pattern on the TiD01 and TiD02 surfaces. On the TiD05 and TiD10 surfaces, this orientation was not observed. In addition, TEM and CLSM demonstrated that the focal adhesion points (FAP) were located mainly on the surface pattern ridges. TEM revealed that FAP were wrapped occasionally around the edges of the ridges. Only the RDFs on both the TiD05 and TiD10 surfaces protruded into the grooves and possessed FAP on the walls of the grooves. Attachment to the groove floor was observed only on the TiD10 textures. Comparison of these results with earlier observations on microtextured silicone rubber substrata suggests that material-specific properties do not influence the orientational effect of the surface texture on the observed RDF cellular behavior. The proliferation rate of the RDFs, however, seems to be much higher on titanium than on silicone rubber substrata. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 425-433, 1998.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 39 (1998), S. 524-530 
    ISSN: 0021-9304
    Keywords: magnetron sputtering ; calcium phosphates ; hydroxyapatite ; carbonate apatite ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Radiofrequency magnetron sputter deposition was used to deposit Ca-P sputter coatings on titanium discs, and these coatings were implanted subcutaneously into the backs of rabbits. Half of the as-sputtered coatings were subjected to additional heat treatment for 2 h at 500°C. X-ray diffraction (XRD) demonstrated that annealing at 500°C changed the amorphous sputtered coating into an amorphous-crystalline apatite structure. Scanning electron microscopic (SEM) examination of the sputtered coatings showed excellent coverage of the substrate surface. Annealing of the 4-μm-thick coatings resulted in the appearence of small cracks. SEM demonstrated that until 4 weeks of implantation, all heat-treated coatings were present and all amorphous coatings were completely or mostly dissolved. Fourier transform infrared spectroscopy showed the formation of carbonate apatite (CO3-AP) on these specimens. Furthermore, XRD analysis showed that these CO3-AP precipitated coatings disappeared after 8 weeks of implantation. On the other hand, SEM inspection of these specimens revealed that the 4-μm heat-treated coating was still partially maintained and that small Ca-P crystals were present on the titanium substrate. On the basis of these results, we conclude that apparently 0.1 μm heat-treated Ca-P sputter coating is of sufficient thicknesses to stimulate carbonate apatite deposition under in vivo conditions. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 524-530, 1998.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 42 (1998), S. 634-641 
    ISSN: 0021-9304
    Keywords: biocompatibility ; subcutaneous implant ; implant surface ; microgrooves ; in vivo ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We investigated the behavior of microgrooved implants in soft tissue using polystyrene implantable disks, either smooth or microgrooved (1-10 μm) on both sides. The implants were placed subcutaneously in a goat for 1, 4, or 12 weeks. Light and transmission electron microscopy showed that fibrous capsule formation around the implants was fairly uniform. After 1 week the implants were covered with a fibrous capsule about 80 μm thick. The collagen matrix was loose, and many inflammatory cells were present. After 4 weeks the matrix was more dense and contained many newly formed blood vessels. At the implant surface a layer of inflammatory cells about 10 μm thick had accumulated. Finally, after 12 weeks the matrix had densified. One cellular layer of inflammatory cells was present at the implant surface. We carried out histomorphometric measurements of capsule thickness, inflammatory layer thickness, and the number of blood vessels. Capsule thickness appeared not to decrease with time. Further, these measurements showed that there were no differences in tissue reaction between smooth and microgrooved implants. On the basis of our observations, we suggest that 1 μm deep and 1-10 μm wide microgrooves do not influence tissue response around polystyrene implants in soft tissue. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 42, 634-641, 1998.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 511-518 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To evaluate the effect of surface treatment and surface microtexture on cellular behavior, smooth and microtextured silicone substrata were produced. The microtextured substrata possessed parallel surface grooves with a width and spacing of 2.0 (SilD02), 5.0 (SilD05), and 10 μm (SilD10). The groove depth was approximately 0.5 μm. Subsequently, these substrata were either left untreated (NT) or treated by ultraviolet irradiation (UV), radiofrequency glow discharge treatment (RFGD), or both (UVRFGD). After characterization of the substrata, rat dermal fibroblasts (RDF) were cultured on the UV, RFGD, and UVRFGD treated surfaces for 1, 3, 5, and 7 days. Comparison between the NT and UV substrata revealed that UV treatment did not influence the contact angles and surface energies of surfaces with a similar surface topography. However, the contact angles of the RFGD and UVRFGD substrata were significantly smaller than those of the UV and NT substrata. The dimension of the surface microevents did not influence the wettability characteristics. Cell culture experiments revealed that RDF cell growth on UV-treated surfaces was lower than on the RFGD and UVRFGD substrata. SEM examination demonstrated that the parallel surface grooves on the SilD02 and SilD05 substrata were able to induce stronger cell orientation and alignment than the events on SilD10 surfaces. By combining all of our findings, the most important conclusion was that physicochemical parameters such as wettability and surface free energy influence cell growth but play no measurable role in the shape and orientation of cells on microtextured surfaces. © 1995 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Various studies already have shown that the occurrence of oral implant failure is higher in the maxilla than in the mandible. To learn whether Ca-P coatings can improve the success rate of oral implants in the maxilla, three different plasma-sprayed, Ca-P-coated, self-tapping Brånemark® implants were inserted in the trabecular bone of the maxilla. Before the insertion of the implants, the two first upper premolars of 16 goats were bilaterally extracted. Four months later, each animal received four types of implants: three different Ca-P-coated types and one uncoated. After an endosseous period of 6 months, the implants were provided with permucosal abutments. Four months later the animals were killed. At the end of the experiment, it appeared that 10 of the 16 installed noncoated implants had failed while of the 48 Ca-P-coated implants, only 6 had failed. All successful implants were retrieved and prepared for histomorphometrical evaluation of the bone and gingiva response. The Ca-P-coated implants showed a significantly greater percentage of bone in contact with the implant surface compared with the uncoated implants. The length of the epithelium was not significantly different for the coated compared to the uncoated implants, but the connective tissue was significantly thicker for the noncoated implants than for the Ca-P-coated implants. Also, measurements revealed that all coatings showed reduction in thickness. On the basis of these findings, we concluded that the application of Ca-P coatings (1) improves the bone-implant reaction, although all coatings reduced in thickness, and (2) is of benefit during the healing period in less mineralized trabecular bone. © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to calcium phosphate (Ca-P) plasma-spray and radiofrequency magnetron sputter-coated implants with comparable roughness. Therefore, tapered conical screw designed implants were installed in the trabecular bone of the femurs of nine goats. They were provided with two types of coatings, a plasma-spray dual coating of fluorapatite and hydroxyapatite (FA/HA-PS) and a titanium plasma-spray coating, covered with an amorphous Ca-P magnetron sputtercoating (TPS/Ca-P-a). These implants were evaluated histologically and mechanically after 3 months of implantation. A well-controlled method to apply and measure a torsional force to load the screw-type implants to the point of failure was introduced. All implants healed uneventful and were well fixed. No significant difference (Student t test, p 〉 0.05) for the torsional failure force was measured for both type of coatings. Nevertheless, SEM revealed differently situated fracture planes. Light microscopy showed intimate bone-implant contact for both types of coatings; original drill margins were still visible. A lamellar type of bone with some remodeling lacunae was shown. Histomorphometry revealed a higher percentage of bone contact for the FA/HA-PS-coated implants (student t test, p 〈 0.05). Measurement of the amount of bone revealed more bone mass around TPS/Ca-P-a-coated implants (analysis of variance and Tukey multiple comparison, p 〈 0.05). © 1997 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 40 (1998), S. 464-474 
    ISSN: 0021-9304
    Keywords: calcium phosphate coatings ; magnetron sputtering ; osteoblast ; in vitro ; bone ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In previous studies we developed a RF magnetron sputter technique for the production of thin Ca-P coatings. With this technique coatings can be produced that vary in Ca/P ratio as well as in structural appearance. The aim of this investigation was to obtain more understanding of the biological behavior of these coatings by way of in vitro experiments. The effect of noncoated titanium (Ti) and three different Ca-P-sputtered surfaces on the proliferation and differentiation (morphology and matrix production) of osteoblast-like cells was studied. Proliferation was determined using counting procedures; morphology was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Fluorescent markers and energy-dispersive X-ray microanalysis (EDX) were used to obtain quantitative and compositional information about the resultant calcified extracellular matrix (ECM). Results demonstrated that proliferation of the osteoblast-like cells was significantly (p 〈 0.05) higher on noncoated than on Ca-P-coated samples. On the other hand, more mineralized ECM was formed on the coated surfaces. In addition, TEM confirmed that the cells on the coated substrates were surrounded by ECM with collagen fibers embedded in crystallized, needle-shaped structures. On the basis of these findings, we concluded that: (1) the investigated Ca-P sputter coatings possess the capacity to activate the differentiation and expression of osteogenic cells, and (2) bone formation proceeds faster on Ca-P surfaces than on Ti substrates. Further, this bone-inductive effect appeared to be dependent on the Ca-P ratio of the deposited coatings. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 464-474, 1998.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...