Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (6)
  • 1965-1969
  • Column liquid chromatography  (4)
  • Paraportal circulation  (2)
Materialart
Erscheinungszeitraum
  • 1995-1999  (6)
  • 1965-1969
Jahr
  • 1
    ISSN: 1279-8517
    Schlagwort(e): Paraportal circulation ; Portal vein ; Left gastric vein ; Left inferior phrenic vein ; Left renal vein
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract During dissection practice, an enlarged communicating vein between the portal and left renal vv. was found. This paraportal route seemed to be formed by the union of the left gastric v. and the cardioesophageal branch of the left inferior phrenic v. which opened into the left renal v.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 49-51 
    ISSN: 1279-8517
    Schlagwort(e): Paraportal circulation ; Portal vein ; Left gastric vein ; Left inferior phrenic vein ; Left renal vein
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Beschreibung / Inhaltsverzeichnis: Résumé Au cours d'une autopsie a été trouvée une large veine communicante entre la v. porte et la v. rénale gauche. Cette voie para-portale semblait formée par l'union de la v. gastrique gauche et de la branche cardio-oesophagienne de la v. phrénique inférieure gauche, qui s'ouvrait dans la v. rénale gauche.
    Notizen: Summary During dissection practice, an enlarged communicating vein between the portal and left renal vv. was found. This paraportal route seemed to be formed by the union of the left gastric v. and the cardioesophageal branch of the left inferior phrenic v. which opened into the left renal v.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Diltiazem hydrochloride stereoisomers ; Chiralcel OF ; Chiral inversion ; Epimerization
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The simultaneous stereospecific assay of four stereoisomers of diltiazem hydrochloride in bulk drug and aqueous solution was developed using HPLC on a Chiralcel OF column. The four isomers were quantitated with good precision by the internal standard method. The chiral inversion of (+)-cis-diltiazem hydrochloride in vitro, stability of its (2S, 3S) configuration in the solid and aqueous states was examined by HPLC. Chiral inversion of (+)-cis-diltiazem hydrochloride was not observed in the solid state, and its (2S, 3S) configuration was stable to heat, humidity and light. Chiral inversion of (+)-cis-diltiazem hydrochloride (2S, 3S) was observed in aqueous solution under UV, but not in aqueous solution stored at 80°C for 5h nor under visible light for 10 h. The (+)-cis-diltiazem hydrochloride (2S, 3S) epimerized to (+)-trans-diltiazem hydrochloride (2R, 3S) with a half-life of 5h in aqueous solution under UV but the reverse chiral inversion of (+)-trans-diltiazem hydrochloride (2R, 3S) to (+)-cis-diltiazem hydrochloride (2S, 3S) was not observed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Capillary electrophoresis ; Enantiomer separation ; Trimetoquinol ; Denopamine ; Timepidium
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Two methods for the direct separation of the enantiomers of trimetoquinol hydrochloride, denopamine and timepidium bromide were investigated, namely capillary zone electrophoresis (CZE) using cyclodextrins (CDs) (CD-CZE) and high-performance liquid chromatography (HPLC) using chiral stationary phases (CSPs). By CZE, separation of the enantiomers of trimetoquinol was successfully achieved when using β-cyclodextrin (β-CD), heptakis(2,6-di-0-methyl)-β-cyclodextrin (DM-β-CD) and β-CD polymer, but direct HPLC separation of the enantiomers was not successful. The enantiomers of denopamine were successfully separated by both CZE, employing DM-β-CD under acidic conditions, and HPLC, with cyclodextrin immobilized CSPs (CD-CSPs). Timepidium bromide, which is a racemic drug, was successfully enantioseparated by both CD-CZE and HPLC with CD-CSPs. The CD-CZE mode was selected as the optical purity testing method for trimetoquinol and denopamine because of the superiority of capillary electrophoretic (CE) techniques. Method validation results obtained clearly show that the CE method would be useful as an quality control method for assessing the optical purity of the drugs.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Desacetyl diltiazem hydrochloride stereoisomers ; Chiralcel OF ; Chiral inversion ; Epimerization
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Direct resolution of four stereoisomers of the related compound of diltiazem hydrochloride, namely desacetyl diltiazem hydrochloride, was studied by both normal and reversed-phase chiral HPLC. The four stereoisomers were completely resolved on a Chiralcel OF column. The technique developed was applied to a chiral inversion study of desacetyl diltiazem hydrochloride. This inversion was observed neither in the solid state, in aqueous solution at 100°C for 3 h nor under visible light for 10h, but was observed in aqueous solution under UV irradiation. The (+)-(2S, 3S)-cis-desacetyl diltiazem hydrochloride degraded with a half-life of 1.9 h in aqueous solution under UV and epimerized to (+)-(2R, 3S)-trans-desacetyl diltiazem hydrochloride. Similarly, (+)-(2S, 3S)-cis-desacetyl diltiazem hydrochloride degraded about three times faster than diltiazem hydrochloride. Reverse epimerization of (+)-(2R, 3S)-trans-desacetyl diltiazem hydrochloride to (+)-(2S, 3S)-cis-desacetyl diltiazem hydrochloride was not observed. The overall degradation was the result of two competitive processes, the epimerization and the decomposition of the benzothiazepin ring. The degradation and epimerization rate of (+)-(2S, 3S)-cis-desacetyl diltiazem hydrochloride in solution under UV depended upon the solvent, the aqueous pH, and concentration.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 1612-1112
    Schlagwort(e): Column liquid chromatography ; Aldehydes, aliphatic ; 1,3-Cyclohexanedione (CHD) ; Fluorimetric detection ; Plasma analysis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary A simple and sensitive method is proposed for the measurement of aldehydes in plasma. The plasma samples are treated with 1,3-cyclohexanedione (CHD) and after addition of the internal standard (the CHD derivative of octaldehyde) are analysed by reversed-phase high-performance liquid chromatography with an acetonitrile-water gradient as the mobile phase. Detection is by fluorimetry with excitation at 395 nm and emission at 457 nm. In plasma samples spiked with aldehydes, the calibration curves showed good linearity in the range 0–10 μg mL−1. The recoveries of aldehydes were quantitative; coefficients of within-day and between-day variation were less than 13% and 11%, respectively. Applications to human and some animal plasma samples are reported.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...