Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • Abdomen  (2)
  • Fractal structure  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of comparative physiology 184 (1999), S. 73-84 
    ISSN: 1432-1351
    Keywords: Key words Locomotor activity ; Time series analysis ; Bout structure ; Fractal structure ; Aging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract The temporal pattern of locomotor activity of single Drosophila melanogaster flies freely walking in small tubes is described. Locomotor activity monitored by a light gate has a characteristic time-course that depends upon age and the environmental conditions. Several methods are applied to assess the complexity of the temporal pattern. The pattern varies according to sex, genotype, age and environmental conditions (food; light). Activity occurs clustered in bouts. The intrinsic bout structure is quantified by four parameters: number of light gate passages (counts) per bout, duration of a bout, pause between two successive bouts and mean bout period. In addition, the distribution of the periods between light-gate crossings (inter-count intervals) as function of inter-count interval duration reveals a power law, suggesting that the overall distribution of episodes of activity and inactivity has a fractal structure. In the dark without food, the fractal dimension which represents a measure of the complexity of the pattern is sex, genotype and age specific. Fractality is abolished by additional sensory stimulation (food; light). We propose that time-course, bout structure and fractal dimension of the temporal pattern of locomotor activity describe different aspects of the fly's central pattern generator for locomotion and its motivational control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 382 (1997), S. 380-392 
    ISSN: 1435-2451
    Keywords: Key words Drainage ; Abdomen ; Effects ; Schlüsselwörter Abdominaldrainagen ; Verhalten ; Auswirkungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In einer prospektiven randomisierten Studie an 30 Mischrassekaninchen wurden nach 2 standardisierten Dickdarmresektionen bei je 10 Tieren Penrose-, Gummirohr- und Silikonkautschukrohrdrainagen in den Unterbauch eingesetzt und als geschlossenes Drainagesystem subkutan abgeleitet. Eine der Darmanastomosen wurde ebenfalls drainiert. Auswertung und Befunderhebung erfolgten am 7. postoperativen Tag. An mechanischen Auswirkungen wurde nur 1mal ein Druckulkus durch Anstemmen einer Silikonrohrdrainage im Unterbauch beobachtet. „Wetz“-Spuren waren sonst nur lokale unspezifische Entzündungsreaktionen gegen den Fremdkörper Drain, die in gleichem Maß bei allen Draintypen auftraten. Eine vom Drain ausgehende, aufsteigende Infektion wurde nicht beobachtet. Infektionen hatten ihren Ursprung immer von Komplikationen im Operationsgebiet. Entgegen bisheriger Vorstellungen waren die Drainagen im Unterbauch frei von Verwachsungen und Verklebungen zu den Organen der Bauchhöhle. Lediglich die Durchtrittsstelle an der Bauchdecke und der Baumwolldocht der Penrose-Drainage zeigten regelmäßig Verwachsungen. Die ausgedehnten Verwachsungen der Anastomosendrainagen waren auf Auswirkungen der Darmanastomosen und deren Komplikationen zurückzuführen. Gummirohr und Latexgummi zeigten materialbedingt großflächige Fibrinauflagerungen. Durch Verstopfung des Drainrohrs und des Baumwolldochts mit Fibrinkoageln waren nach 7 Tagen nur noch ca. 20% der Drainagen durchgängig. Prinzipiell bestand kein Unterschied im Verhalten der 3 verschiedenen Drainagetypen bei Materialvorteilen des Silikonkautschuks.
    Notes: Abstract In a prospective randomised study 30 mongrel rabbits recieved two standard colon-resections. Three types of drains were testet: (latex-rubber-) Penrose-drains, rubbertube- and silikontube-drains, which were placed in the lower abdomen. As a closed drainage-system the extraperitoneal tip of the drain was placed in a closed subcutis-pocket. One of the two colon-anastomoses also was drained. The findings were recorded on the 7th postoperative day. A single mechanic alteration was found, an ulcer caused by a silicon-drain, that pushed against the abdominal wall. The other signs of mechanic irritation were microscopically unspecified inflammatory reactions to the foreign body drain. There was no ascending infection caused by the drain. All infections came from complications of the colon resections. In contrast to common opinions the drains in the lower abdomen showed no adhäsions to the abdominal wall or organs. Only the entrance of the drain into the peritoneum and the cotton-gaze of Penrose-drains showed in nearly all cases adhesions. The large amount of adhesions to the anastomosis-drains came from complications of the colon-anastomoses. As a cause of material, rubber- and latex-rubber-drains showed large fibrin-clotts on their surfaces. 7 days after the operation only about 20% of the drains had sufficient function. The rest was occluded by fibrin-clotts in the lumen of the drain or the cotton-gaze. Over all there is no difference in changes and effects of the three different types of drains, but silicon as material showed advantages.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1435-2451
    Keywords: Drainage ; Abdomen ; Effects ; Abdominaldrainagen ; Verhalten ; Auswirkungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung In einer prospektiven randomisierten Studie an 30 Mischrassekaninchen wurden nach 2 standardisierten Dickdarmresektionen bei je 10 Tieren Penrose-, Gummirohr- und Silikonkautschukrohrdrainagen in den Unterbauch eingesetzt und als geschlossenes Drainagesystem subkutan abgeleitet. Eine der Darmanastomosen wurde ebenfalls drainiert. Auswertung und Befunderhebung erfolgten am 7. postoperativen Tag. An mechanischen Auswirkungen wurde nur 1mal ein Druckulkus durch Anstemmen einer Silikonrohrdrainage im Unterbauch beobachtet. „Wetz“-Spuren waren sonst nur lokale unspezifische Entzündungsreaktionen gegen den Fremdkörper Drain, die in gleichem Maß bei allen Draintypen auftraten. Eine vom Drain ausgehende, aufsteigende Infektion wurde nicht beobachtet. Infektionen hatten ihren Ursprung immer von Komplikationen im Operationsgebiet. Entgegen bisheriger Vorstellungen waren die Drainagen im Unterbauch frei von Verwachsungen und Verklebungen zu den Organen der Bauchhöhle. Lediglich die Durchtrittsstelle an der Bauchdecke und der Baumwolldocht der Penrose-Drainage zeigten regelmäßig Verwachsungen. Die ausgedehnten Verwachsungen der Anastomosendrainagen waren auf Auswirkungen der Darmanastomosen und deren Komplikationen zurückzuführen. Gummirohr und Latexgummi zeigten materialbedingt großflächige Fibrinauflagerungen. Durch Verstopfung des Drainrohrs und des Baumwolldochts mit Fibrinkoageln waren nach 7 Tagen nur noch ca. 20% der Drainagen durchgängig. Prinzipiell bestand kein Unterschied im Verhalten der 3 verschiedenen Drainagetypen bei Materialvorteilen des Silikonkautschuks.
    Notes: Abstract In a prospective randomised study 30 mongrel rabbits recieved two standard colon-resections. Three types of drains were testet: (latex-rubber-) Penrose-drains, rubbertube- and silikontube-drains, which were placed in the lower abdomen. As a closed drainage-system the extraperitoneal tip of the drain was placed in a closed subcutis-pocket. One of the two colon-anastomoses also was drained. The findings were recorded on the 7th postoperative day. A single mechanic alteration was found, an ulcer caused by a silicon-drain, that pushed against the abdominal wall. The other signs of mechanic irritation were microscopically unspecified inflammatory reactions to the foreign body drain. There was no ascending infection caused by the drain. All infections came from complications of the colon resections. In contrast to common opinions the drains in the lower abdomen showed no adhäsions to the abdominal wall or organs. Only the entrance of the drain into the peritoneum and the cotton-gaze of Penrosedrains showed in nearly all cases adhesions. The large amount of adhesions to the anastomosis-drains came from complications of the colon-anastomoses. As a cause of material, rubber- and latex-rubber-drains showed large fibrinclotts on their surfaces. 7 days after the operation only about 20% of the drains had sufficient function. The rest was occluded by fibrin-clotts in the lumen of the drain or the cotton-gaze. Over all there is no difference in changes and effects of the three different types of drains, but silicon as material showed advantages.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...