Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (4)
  • Chemistry  (2)
  • Arabidopsis thaliana  (1)
  • Protein synthesis  (1)
  • Adenovirus
  • Epstein-Barr virus
  • Nuclear reactions
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Plant cell reports 18 (1998), S. 255-259 
    ISSN: 1432-203X
    Keywords: Key words Fusicoccin ; Arabidopsis thaliana ; Selection method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract A mutagenised population of seeds of Arabidopsis thaliana was allowed to germinate in the presence of the positively charged aminoglycoside hygromycin (4 μg/ml) and the fungal toxin fusicoccin (5×10–6 m). This hygromycin concentration, which is non-toxic by itself, becomes toxic when used together with fusicoccin, which stimulates cation uptake. Seeds that had germinated after 3–5 days and produced seedlings with green cotyledons were potentially resistant to fusicoccin and were therefore transferred into sterile Magenta vessels containing 1/2-strength Murashige and Skoog medium. This selection procedure is non-destructive, i.e. it allows the recovery of viable seedlings and their growth into adult plants thus permitting direct physiological characterisation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1615-6102
    Keywords: Auxin ; Maize coleoptiles ; Membrane potential ; Cycloheximide ; Protein synthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The contribution of protein synthesis and secretion to indol acetic acid (IAA) induced polarisation of the plasma membrane voltage (V M) was investigated. TheV M of coleoptiles fromZea mays was measured in the presence of known inhibitors of protein- and RNA synthesis, as well as those of Golgi-mediated vesicle secretion. Inhibitors were applied under conditions at which they are known to abolish IAA stimulated H+ secretion and cell elongation effectively. Cycloheximide (CHI), an inhibitor of protein synthesis, caused depolarisation ofV M with a half maximal concentration of approximately 20 μM. At 100 μM CHI,V M depolarised to a new stable voltage with a half time of 9.8 ± 0.6 min. The temporal similarity of CHI-induced depolarisation and cessation of coleoptile elongation suggests that the induced change inV M underlies inhibition of elongation. CHI evoked membrane depolarisation to a final voltage of about −100 mV irrespective of the presence or absence of auxin in the external medium. Thus, CHI probably affected constitutive membrane transport properties independently of IAA-induced modulation of transport proteins. Cordycepin (COR), an inhibitor of RNA synthesis, had no significant effect at 400 μM onV M of IAA-treated cells, suggesting that gene transcription for transport- or regulatory protein synthesis was not essential for IAA-generated polarisation ofV M. Brefeldin-A (BFA), an inhibitor of Golgi-mediated vesicle secretion in maize coleoptiles, had no perceivable effect at 20 mg/1 onV M of IAA-treated coleoptile cells, demonstrating that constitutive or IAA-stimulated protein secretion was not essential for the mechanism underlying IAA-evokedV M polarisation. Hence, IAA-stimulated and COR/BFA-depressed H+ extrusion in elongating coleoptiles may not be entirely mediated by auxin-enhanced ATPase activity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 695-699 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We evaluated bone microhardness at the interface with hydroxyapatite-coated stainless-steel pins used in an external fracture fixation system. Pins were transversally inserted into the diaphyses of sheep tibiae and were loaded in for 6 weeks. Uncoated pins were implanted as controls. Microhardness analysis, based on the measure of the resistance of the bone to the penetration of a small diamond pyramid, yielded an accurate and reproducible measure of the mineralization degree and of the orientation of collagen fibers. Bone tissue close to the pin is less hard than bone tissue far from it. Moreover, the presence of hydroxyapatite coating on the pins did not significantly affect bone hardness; actually, the mean hardness at the interface with the pins was 56.9 Vickers degrees, whereas at the interface with the uncoated pins it was 62.2. It can be concluded that, 6 weeks postsurgery, the bone growing into the threadings of a loaded screwed implant reached maturity at a degree lower than that of the host both uncoated and coated implants. © 1995 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: X-ray diffraction ; ceramic ; external fixation ; coating ; biocompatibility ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The in vivo compatibility and degradation aspects of an innovative coating to be sprayed onto titanium implants were investigated. The surface of fluorinated apatite (fHA), consisting of fluorhydroxyapatite plasma sprayed in a vacuum atmosphere, was treated with carbonate to improve its biological compatibility. fHA coating was compared with titanium implants coated (a) with hydroxyapatite (HA) by the traditional plasma spraying, and (b) with titanium oxide (TiOx). Screw-shaped implants were inserted in the cortical bone of sheep tibiae. X-ray diffraction (XRD) analysis of bone tissue and coatings was carried out at 2, 4, 12 and 36 weeks after surgery. The crystallographic habit of the implant-facing bone, as well as the structural stability of the coating, were evaluated. For each time period and type of ceramic bone apatite lattice at the interface, no significantly different reference apatite lattice and no foreign peak were recorded. Two weeks after implantation, the bone at the interface was strongly unmineralized in all samples; after 4 weeks, poorly mineralized bone microareas decreased. At 12 weeks, the newly formed bone tissue at the interface with both the new coating and HA coating was shown to be fully mineralized; this crystallographic habit was retained at 36 weeks, when particle release from the tested material was lower compared to the controls. The XRD pattern of bone apatite surrounding the coating particles was unmodified. The innovative coating did not alter the mineralization process at the interface. It improved implant osteointegration, mainly due to a limited release of particles. Consequently, clinical performance of external fixation treatment could be improved by modifying the chemical composition of the implant surface. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 40, 86-91, 1998.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...