Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1995-1999  (5)
  • Laparoscopy  (2)
  • Coagulation  (1)
  • Gastrostomy  (1)
  • Pulmonary circulation
  • mouse
  • mouse chromosome 2
Materialart
Erscheinungszeitraum
Jahr
  • 1
    ISSN: 1432-1238
    Schlagwort(e): Key words Antithrombin III ; Coagulation ; Disseminated intravascular coagulation ; Disseminated intravascular coagulation ; Liver failure ; Liver cirrhosis ; Liver transplantation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Since antithrombin III (AT III) substitution to normal activities could not be shown to have major beneficial effects in patients with end-stage chronic liver disease in a variety of clinical settings, we tested the hypothesis that substitution to supranormal activities decreases systemic procoagulant turnover better in this patient group. Design: Controlled prospective clinical study. Setting: Operating rooms at a University Hospital. Patients: Twenty-four patients with histologically verified liver cirrhosis consecutively scheduled for liver transplantation. Interventions: Nineteen patients were given an antithrombin III concentrate to achieve either 100 % (n = 10) or 175 % (n = 9) AT III activity. Control patients (n = 5) received saline 0.9 % instead. Measurements and results: Molecular markers of coagulation activation, platelet count and aggregability, and global coagulation variables were measured prior to AT III infusion and 60 min thereafter. In both AT III-treated groups thrombin-antithrombin III-complex increased significantly (p 〈 0.005), whereas prothrombin fragment F1 + 2, soluble fibrin and D-dimer concentrations, as well as other variables, did not show major changes. Conclusions: Despite thrombin inhibition by AT III in patients with end-stage chronic liver disease, systemic procoagulant turnover was not significantly decreased 60 min after AT III application even to supranormal activities. Replenishment of the inhibitory antithrombin III pool, decreased in chronic liver disease, should not be expected to slow down the baseline consumptive component of the haemostatic disorder in this patient group.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1238
    Schlagwort(e): Key words Haemoconcentration ; Haemodilution ; Pressure-flow relationship ; Pulmonary circulation ; Pulmonary vascular flow resistance ; Pulmonary vascular hypertension
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Pulmonary vascular flow resistance depends on blood viscosity, mainly due to haematocrit, and on vessel dimensions determining blood volume in this highly compliant vascular bed. We, therefore, evaluated the interaction between haematocrit, blood flow, and transpulmonary vascular pressure gradient under conditions of controlled pulmonary blood volume. Design: Experimental study in isolated zone-III rabbit lungs perfused with autologous blood. Setting: Laboratory for experimental studies. Interventions: Stepwise and independent variation of flow (50, 100, and 200 ml/min), pulmonary blood volume (increments of 2.5 ml and 5 ml imposed by changes of left atrial pressure), and haematocrit (0–50 %) varied by haemodilution (Krebs-Henseleit/albumin) or haemoconcentration (centrifugation). Measurements: Pulmonary arterial, left atrial, and airway pressures as well as reservoir volume (reflecting reciprocal changes of lung blood volume) and lung weight. Results: Haemodilution from the normal haematocrit (32 %) to 10 % at constant pulmonary blood volume and flow decreased flow resistance only slightly, whereas haemoconcentration (50 %) increased flow resistance up to 130 %. At the same time increments of in pulmonary blood volume of 2.5 and 5 ml (approx. 15 and 30 % of normal pulmonary blood volume) at constant haematocrit significantly shifted downwards pressure-flow relationships for all investigated haematocrits (0–50 %). Conclusions: Because of the multiple interrelationships between haematocrit, blood flow and pulmonary blood volume, haematocrit effects on pulmonary flow resistance and pressure-flow relationships in the pulmonary vasculature should be studied at controlled blood volume. While haemodilution only has minor effects, haemoconcentration changes pressure-flow relationships markedly. Pulmonary blood volume has a major impact on slope and position of pressure-flow relationships for all haematocrits investigated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 668-670 
    ISSN: 1432-2218
    Schlagwort(e): Lung transplantation ; Laparoscopic fundoplication ; Laparoscopy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Upper midline laparotomy in the presence of pulmonary failure is often complicated by a prolonged period of mechanical ventilation postoperatively. We report the successfull performance of laparoscopic fundoplication, without ventilatory suport, in a woman with end stage pulmonary disease and resting hypercarbia, one month prior to lung transplantation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1432-2218
    Schlagwort(e): Laparoscopy ; Hernioplasty ; Technique ; Complications
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Smaller individual series on the outcome of laparoscopic hernioplasty techniques have been reported. This study reports on the complications of 3,229 laparoscopic hernia repairs performed by the authors in 2,559 patients. The TAPP (transabdominal preperitoneal) technique was the most frequently performed: 1,944 (60%). The totally preperitoneal technique was performed 578 (18%) times. The IPOM (intraperitoneal onlay mesh) repair was performed 345 (11%) times. The plug-and-patch technique was used 286 (9%) times and simple closure of the hernia defect without mesh was used in 76 (2%) repairs. Overall, there were 336 (10%) complications: 17 (0.5%) major and 265 (8%) minor. There were 54 (1.6%) recurrences, with a mean follow-up of 22 months. The TAPP technique had 19 (1%) recurrences and 141 (7%) complications. There were four bowel obstructions in this subgroup from herniation of small bowel through the peritoneal closure and trocar sites. The totally preperitoneal technique had no recurrence and 60 (10%) complications. The IPOM group had 7 (2%) recurrences and 47 (14%) complications. The plug-and-patch technique had 26 (9%) recurrences and 24 (8%) complications. The simple closure of the internal ring had 2 (3%) recurrences and 10 (13%) complications. Laparoscopic hernioplasty is not without complications. Training, experience, and attention to technique will prevent some of these complications.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Surgical endoscopy and other interventional techniques 9 (1995), S. 831-834 
    ISSN: 1432-2218
    Schlagwort(e): Trichobezoar ; Gastrostomy ; Laparoscope instrument ; Foam-rubber stent
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Trichobezoars are difficult to remove endoscopically, often cause nausea and vomiting, and can result in small-bowel obstruction. A patient with a trichobezoar presented to our clinic with symptoms of partial small-bowel obstruction. Multiple attempts at flexible endoscopic removal were unsuccessful. Two large-diameter percutaneous gastrostomies with an inflatable balloon and distal foam-rubber stent to assure intragastric positioning were introduced under general anesthesia. Visualization was provided by a 0° panavision laparoscope placed through one of the gastrostomies. The bezoar was removed through the second gastrostomy using standard laparoscopic instruments. The patient made an uneventful recovery. This is the first reported case of percutaneous removal of a trichobezoar. We conclude large-diameter gastrostomies may serve as a port of access for numerous other intraluminal procedures.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...