Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • Column liquid chromatography  (2)
  • Engineering General
  • Fe-Versorgung
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Column-switching ; Parathion, and metabolites in serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new high-performance liquid chromatographic method with column-switching has been developed for the simultaneous determination of parathion and its metabolites such asp-nitrophenol and paraoxon in serum. Serum samples were injected onto a precolumn packed with LiChroprep RP-8 after simple dilution with 20% phosphoric acid. Polar plasma components were washed with 0.02 M phosphate buffer (pH 3.0). After valve switching, the concentrated compounds were eluted in back-flush mode and separated on a Ultracarb ODS 30 column with a gradient of acetonitrile −0.01 M phosphate buffer (pH 3.0) as mobile phase. The method showed excellent precision, accuracy and speed with detection limit of 0.1 μg mL−1. Total analysis time per sample was 〈40 min and coefficients of variation for intra-and inter-assay were 〈4.5%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore columns ; Column-switching ; Myristicin ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A microbore high-performance liquid chromatographic method with column-switching was developed for the analysis of myristicin from rat serum without prepurification. Deproteinization, fractionation, concentration and separation of analyte were carried out by appropriate switching of columns and using solvent mixtures. The method showed excellent precision, accuracy and speed with a detection limit of 10 ng mL−1 from 25 μL of serum. The total analysis time per sample was 25 min and the coefficients of variation for intra- and inter-assay were less than 1.8%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 39 (1996), S. 1903-1914 
    ISSN: 0029-5981
    Keywords: axisymmetric shell ; mixed finite element ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: An efficient, perhaps simplest, three-noded mixed finite element is proposed for axisymmetric shell analysis. The key feature in the present formulation is to start with a better variational principle in which the independent unknowns are only the quantities that can be prescribed at the shell edges. If the consistency for field approximations is satisfied, no other numerical consideration is necessary in the present element. Several examples confirm the satisfactory numerical behaviour of the present mixed element.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...