Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Cyclic neutropenia  (1)
  • boundary-fitted coordinates.  (1)
  • Finite element method
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of engineering mathematics 34 (1998), S. 21-44 
    ISSN: 1573-2703
    Keywords: Navier-Stokes ; finite volume discretization ; staggered grids ; boundary-fitted coordinates.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Technology
    Notes: Abstract The classical staggered scheme for the incompressible Navier-Stokes equations is generalized from Cartesian grids to general boundary-fitted structured grids. The resulting discretization is coordinate-invariant. The unknowns are the pressure and the contravariant volume flux components. The grid can be strongly nonuniform and nonorthogonal. The smoothness properties of the coordinate mapping are carefully taken into account. As a result, the accuracy on rough grids is found to be at least as good as for typical finite element and nonstaggered finite volume schemes. Extension to compressible flows results in a scheme with Mach-uniform accuracy and efficiency for Mach numbers ranging from M = 0 to M 〉 1. Accurate discretization of two-equation turbulence models is also possible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Pediatric surgery international 10 (1995), S. 175-176 
    ISSN: 1437-9813
    Keywords: Cyclic neutropenia ; Clostridial myonecrosis ; Gas gangrene ; Clostridium septicum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A patient with cyclic neutropenia suffered full-thickness loss of her right abdominal wall and thigh muscles from clostridial myonecrosis. No port of entry was definitely identified. The sepsis and myonecrotic process were controlled by resuscitative measures, extensive multisession debribement, and hyperbaric treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...