Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • Embolisation  (1)
  • Keywords: Internal carotid artery; dissecting aneurysm; stent; ultrasound imaging.  (1)
  • 1
    ISSN: 0942-0940
    Keywords: Keywords: Internal carotid artery; dissecting aneurysm; stent; ultrasound imaging.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary  We present a case of a cervical internal carotid artery aneurysm that caused cerebral embolism. This lesion was supposed to be a dissecting aneurysm due to blunt neck injury. The large aneurysm with intramural thrombus was treated with endovascular placement of a balloon-expandable stent. Both CT and MRI were useful for evaluating the size and characteristics of the aneurysmal wall. Intravascular ultrasound imaging was also useful for evaluation of the satisfactory stent deployment and identification of the neck of the aneurysm. We disscuss effectiveness of endovascular stenting for cervical internal carotid artery aneurysm with intramural thrombus and the usefulness of a combination of the neuroradiological imaging before, during and after the interventional procedure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Aneurysm intracranial ; Magnetic resonance imaging ; Embolisation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract To determine when and how intracranial aneurysms causing mass effect change following endovascular treatment, we used MRI to assess patients for 2–3 years after the interventional procedure. Nine patients who had aneurysms compressing the surrounding structures underwent endovascular treatment. Proximal occlusion of the parent artery was performed in seven cases, and in two the aneurysm was embolised with microcoils. After embolisation, signal intensity within aneurysms tended to be high on both T1- and T2-weighted images. When there was rapid reduction in size high-signal zones within aneurysms became isointense or gave low signal on T1-weighted images. On T2-weighted images, isointense or low-signal foci appeared within high-signal areas in the aneurysm, giving mixed intensity. In typical cases, the mean volume of the aneurysm fell to approximately 30 % of its initial value 2–12 months after treatment. After this, no additional reduction was observed. The aneurysms which showed little signal intensity change tended to shrink more slowly and to a lesser degree than the more typical cases. Aneurysms which gave high signal on both T1- and T2-weighted images early following embolisation shrank more quickly than those showing little signal change.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...