Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (3)
  • Laparoscopy  (2)
  • Hernioplasty  (1)
  • Inferior vena caval blood flow  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 668-670 
    ISSN: 1432-2218
    Keywords: Lung transplantation ; Laparoscopic fundoplication ; Laparoscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Upper midline laparotomy in the presence of pulmonary failure is often complicated by a prolonged period of mechanical ventilation postoperatively. We report the successfull performance of laparoscopic fundoplication, without ventilatory suport, in a woman with end stage pulmonary disease and resting hypercarbia, one month prior to lung transplantation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2218
    Keywords: Laparoscopy ; Hernioplasty ; Technique ; Complications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Smaller individual series on the outcome of laparoscopic hernioplasty techniques have been reported. This study reports on the complications of 3,229 laparoscopic hernia repairs performed by the authors in 2,559 patients. The TAPP (transabdominal preperitoneal) technique was the most frequently performed: 1,944 (60%). The totally preperitoneal technique was performed 578 (18%) times. The IPOM (intraperitoneal onlay mesh) repair was performed 345 (11%) times. The plug-and-patch technique was used 286 (9%) times and simple closure of the hernia defect without mesh was used in 76 (2%) repairs. Overall, there were 336 (10%) complications: 17 (0.5%) major and 265 (8%) minor. There were 54 (1.6%) recurrences, with a mean follow-up of 22 months. The TAPP technique had 19 (1%) recurrences and 141 (7%) complications. There were four bowel obstructions in this subgroup from herniation of small bowel through the peritoneal closure and trocar sites. The totally preperitoneal technique had no recurrence and 60 (10%) complications. The IPOM group had 7 (2%) recurrences and 47 (14%) complications. The plug-and-patch technique had 26 (9%) recurrences and 24 (8%) complications. The simple closure of the internal ring had 2 (3%) recurrences and 10 (13%) complications. Laparoscopic hernioplasty is not without complications. Training, experience, and attention to technique will prevent some of these complications.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 920-924 
    ISSN: 1432-2218
    Keywords: Cardiac hemodynamics ; CO2 pneumoperitoneum ; Inferior vena caval blood flow
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: The effects of carbon dioxide pneumoperitoneum on venous return and cardiac hemodynamics during laparoscopic surgery were studied. Methods: Twelve adult pigs underwent placement of an electromagnetic flow meter across the infrarenal vena cava (IVC) as well as placement of Swan Ganz and arterial monitoring catheters. Measurements of the flow through infrarenal IVC, cardiac output (CO), pulmonary capillary wedge pressure (PCWP), mean arterial pressure (MAP), and heart rate were recorded at baseline, 5 and 60 min following insufflation to 15 mmHg with CO2, and 5 min following desufflation. Stroke volumes and systemic vascular resistance (SVR) were calculated as well. Results: Flow through the IVC dropped by 24 and 31% at 5 and 60 min (p=0.03 and 0.02, respectively). Paradoxically, cardiac output rose by 14 and 28% at 5 and 60 min (p=0.03 at 60 min). Central venous and pulmonary capillary wedge pressures rose transiently by 35 and 36% at 5 min before returning to baseline (p〈0.01). Mean arterial pressure and heart rate remained relatively constant during insufflation. Systemic vascular resistance diminished from 938 dynes/cm/s prior to insufflation to its nadir at 60 min of 650 dynes/cm/s (p〈0.01). Conclusions: These observations suggest potentially complex interactions between the mechanical and systemic effects of the CO2 pneumoperitoneum on venous return. Transient elevations in cardiac filling pressures occur by an unknown mechanism, and a generalized enhanced inotropic state mediated via increased sympathetic outflow is observed in this hypercapnic anesthetized animal model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...