Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 435-439 
    ISSN: 0935-6304
    Keywords: Micellar Electrokinetic Chromatography (MEKC) ; counter pressure moderated MEKC ; migration time window ; peak resolution and peak capacity in MEKC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---The influence of a hydrostatic counter pressure on basic mobility equations in MEKC was analyzed theoretically and investigated experimentally. Taking into account the influence of counter pressure, the modified mobility equations predict a decreased migration time ratio t0/tMC, which was confirmed by results obtained in SDS-MEKC separation of a homologous series of n-alkyl phenyl ketones. As a result, the migration time window could be enlarged in a simple way without having to change the chemistry of the system. Although counter pressures reduce peak efficiency in MEKC by disturbing the plug profile, the concomitant enlargement of the migration time window compensates for this effect. Especially for later migrating compounds, peak resolution could be enhanced at moderate counter pressures. The overall peak capacities within the whole migration window increases slightly when applying counter pressures up to 10 mbar.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 21 (1998), S. 209-214 
    ISSN: 0935-6304
    Keywords: Dual capillary gas chromatography ; non-methane hydrocarbons (NMHCs) ; refocusing ; PLOT column ; carbon dioxide interference ; ambient air analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analytical method based on a dual capillary gas chromatographic technique combining the advantages of GasPro PLOT and a non polar narrow bore WCOT column was developed for the analysis of air samples containing C2-C9 NMHCs. A refocusing step was not required due to the fast heating rate of the sample preconcentration trap and the resolving power of the PLOT column for C2 and C3 NMHCs. Water had to be removed from the air samples to avoid plugging of the columns if the initial GC oven temperature was below ambient temperature. To dry air samples, a scrubber and a cryogenic technique were employed. The interferences caused by carbon dioxide were reduced by purging the loaded sample preconcentration trap with helium. The dual column system was compared to a method employing a refocusing device and a single narrow bore WCOT column. Both systems provided a high degree of precision. However, the dual column approach was superior to the single column system due to better resolution of low molecular weight components.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...