Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-1084
    Schlagwort(e): Key words: MR imaging ; Female ; Pelvis ; Dynamic multiplanar gradient-echo sequence ; T2-weighted fast spin-echo sequence
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. The aim of this study was to compare the diagnostic performance of contrast-enhanced fast multiplanar gradient-echo (GRE) and T2-weighted fast spin-echo (FSE) image sets in the assessment of uterus, cervix, and vagina. Fast (up to 20 contiguous sections in 23 s) multiplanar GRE and FSE images of 45 patients referred for imaging of the female pelvis were evaluated retrospectively with regard to overall image quality and the ability to detect normal anatomic structures, as well as lesion conspicuity. Results were compared with histologic findings (n = 29) or clinical follow-up. Furthermore, a quantitative assessment of contrast-to-noise ratios among normal uterine and cervical structures as well as uterine lesions was performed for both sequences. On GRE images, uterine and cervical differentiation was best seen on the image sets acquired 15 and 60 s following contrast enhancement and results were significantly better compared with delayed images (p 〈 0.05). Delineation of the junctional zone was significantly (p 〈 0.05) better on FSE compared with GRE images; no significant difference was seen for the other anatomic structures. Overall image quality of GRE and FSE images was similar. Sensitivity for lesion detection based on both GRE and FSE images was 96 % with a sensitivity of 93 % for GRE, and 81 % for FSE images alone, respectively. Using the extended McNemar χ 2 test, the difference in diagnostic performance between FSE and GRE revealed no significant difference, whereas the combination of both techniques performed better than FSE imaging alone (p 〈 0.05). The presented data suggest that dynamic contrast-enhanced GRE imaging should be part of an MR examination of the female pelvis. Combined GRE and FSE imaging provide an excellent sensitivity in the assessment of uterine and vaginal pathologies.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1084
    Schlagwort(e): Key words: Breast MRI ; Mammography ; Breast neoplasm ; Contrast-enhanced MRI
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract. The aim of this study was to compare the diagnostic performance of conventional mammography and dynamic contrast-enhanced fast 3D gradient-echo (GRE) MRI regarding the detection and characterization of breast lesions relative to histopathologic analysis and to assess the results of a combined evaluation of both methods. fifty consecutive patients with 63 histopathologically verified breast lesions underwent dynamic contrast-enhanced GRE MRI in addition to routine conventional mammography. All lesions were classified by both methods on a five-point scale as benign or malignant, and the results were correlated to histopathology. Conventional mammography and dynamic MRI yielded a sensitivity and specificity of 82 and 64 %, and 92 and 76 %, respectively. The difference between the results was statistically not significant (p 〉 0.05) with areas under the receiver-operating-characteristics curves of 0.807 for mammography and 0.906 for MR imaging. Combination of the results of both methods slightly increased the sensitivity for detection of breast cancer to 95 % but decreased specificity to 52 %. In this selected patient subset, including only patients referred for excisional biopsy, contrast-enhanced dynamic MRI proved more sensitive and specific than conventional mammography regarding the detection of malignancy. While a combination of both methods yields a slightly improved sensitivity, specificity is vastly reduced.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...