Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    ISSN: 1432-1084
    Keywords: Key words: Arteries ; MR ; Magnetic resonance (MR) ; vascular studies ; Magnetic resonance (MR) ; three-dimensional ; Magnetic resonance angiography ; Contrast media
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. In this study, thirty-eight patients with a variety of upper abdominal diseases were examined with three-dimensional time-resolved MR angiography (7 sec/data set). Visualisation of arterial and venous anatomy was excellent in the majority of patients. Moreover, subtraction images could be calculated and organ perfusion could be assessed. It is concluded that this technique opens new perspectives for a comprehensive evaluation of vascular and parenchymal disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 37 (1995), S. 262-266 
    ISSN: 1432-1920
    Keywords: Intracranial aneurysm ; Magnetic resonance angiography ; Time-of-flight ; Black-blood acquisition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The purpose of this study was to compare the accuracy of 3D time-of-flight (TOF) acquisitions in the characterisation of intracranial aneurysms. Fourteen patients with aneurysms proven on intra-arterial angiography were first studied with a 3D TOF acquisition. When the aneurysms were incompletely demonstrated, additional MR angiography (MRA) acquisitions were performed, including black-blood MRA, 2D TOF, phase-contrast and contrast-enhanced TOF. 3D TOF MRA was sufficient for detection of the aneurysm in 13 of 14 cases and characterisation of the aneurysm was possible in 6. All the initial shortcomings of the TOF technique could be analysed and explained by means of additional MRA techniques. This study suggests that the combination of different MRA techniques offers new possibilities for noninvasive investigation of intracranial aneurysms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1432-1920
    Keywords: Cerebral blood vessels, MR ; Magnetic resonance, vascular studies ; Magnetic resonance, contrast enhancement ; Brain, neoplasm, MR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We compared magnetic resonance angiography (MRA) and intra-arterial digital subtraction angiography (IADSA) in the study of brain tumours and assessed the utility of gadolinium-enhanced MRA. We studied 17 patients with supratentorial brain tumors. The entire brain was imaged with multiple overlapping thin volume acquisitions. After IV injection of gadolinium-DTPA, a single thick-slab MRA acquisition was performed. Standard three-dimensional (3D-TOF) acquisitions (in six patients) and 3D-TOF with magnetization transfer prepulse and tilted optimisation nonsaturing radiofrequency excitation pulses (in 11 patients) were used. Displacement of the anterior cerebral artery, main stem and insular branches of the middle cerebral artery was seen well on unenhanced and contrast-enhanced MRA. Displacement of the lenticulostriate and anterior choroidal arteries was seen only once, after Gadolinium. Tumour encasement of the middle cerebral artery was demonstrated in one patient. Tumour vessels were seen in 2 of 8 cases before and 3 of 8 after gadolinium; Tumour hypervascularity was seen only after gadolinium, in 3 of 8 cases. Study of the veins was possible only on gadolinium-enhanced MRA. Displacement of the venous angle was seen in 4 of 7 patients in the frontal, and in all of 8 patients on the lateral projections. Early venous drainage was not seen. Patency of the dural venous sinuses was demonstrated in all patients, but in one neoplastic occlusion of a cortical vein was recognised.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 1432-1920
    Keywords: Key words Temporal bone ; CT ; Temporal bone ; abnormalities ; Computed tomography ; technology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Axial spiral CT of the temporal bones with a nominal slice thickness of 1 mm and 180° linear interpolation was performed in 13 patients. In 18 temporal bones, the spiral data set was used to reconstruct overlapping axial images with a table increment of 0.1 mm. These images gave additional information in four cases: in two by examining the heavily overlapping axial images themselves, and in two by obtaining supplementary information from secondary image reconstructions. In two cases less information was obtained than by using the conventional incremental images. This study shows that reconstructing overlapping slices can be useful, even if the temporal bone is scanned at 1 mm nominal slice thickness.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 41 (1999), S. 190-194 
    ISSN: 1432-1920
    Keywords: Key words Cerebellum ; growth and development ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The MRI findings in rostral vermian dysplasia are described for the first time. Defective foliation and abnormal fissuration of the rostral vermis can clearly be depicted on coronal images. The abnormalities are limited to the anterior lobe of the vermis and its hemisphere extension. A hypothesis is put forward to explain the abnormalities. It is suggested that the vermian changes result from an intrauterine insult at the end of the first trimester. There appears to be a variable degree of expression and associated cerebellar and cerebral cortical abnormalities can be seen. The clinical significance of these findings remains incompletely understood but may be related to the severity of the abnormalities. It is also suggested that a mild degree of vermian rostral dysplasia may represent an incidental imaging finding.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1432-1920
    Keywords: Temporal bone CT ; Temporal bone, abnormalities ; Computed tomography, technology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Axial spiral CT of the temporal bones with a nominal slice thickness of 1 mm and 180° linear interpolation was performed in 13 patients. In 18 temporal bones, the spiral data set was used to reconstruct overlapping axial images with a table increment of 0.1 mm. These images gave additional information in four cases: in two by examining the heavily overlapping axial images themselves, and in two by obtaining supplementary information from secondary image reconstructions. In two cases less information was obtained than by using the conventional incremental images. This study shows that reconstructing overlapping slices can be useful, even if the temporal bone is scanned at 1 mm nominal slice thickness.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 37 (1995), S. 262-266 
    ISSN: 1432-1920
    Keywords: Key words Intracranial aneurysm ; Magnetic resonance angiography ; Time-of-flight ; Black-blood acquisition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The purpose of this study was to compare the accuracy of 3D time-of-flight (TOF) acquisitions in the characterisation of intracranial aneurysms. Fourteen patients with aneurysms proven on intra-arterial angiography were first studied with a 3D TOF acquisition. When the aneurysms were incompletely demonstrated, additional MR angiography (MRA) acquisitions were performed, including black-blood MRA, 2D TOF, phase-contrast and contrast-enhanced TOF. 3D TOF MRA was sufficient for detection of the aneurysm in 13 of 14 cases and characterisation of the aneurysm was possible in 6. All the initial shortcomings of the TOF technique could be analysed and explained by means of additional MRA tech- niques. This study suggests that the combination of different MRA techniques offers new possibilities for noninvasive investigation of intracranial aneurysms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1432-1920
    Keywords: Key words Aneurysm ; intracranial ; Computed tomography ; helical ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Spiral CT and magnetic resonance angiography (MRA) were performed in ten patients with 14 intracranial aneurysms known from conventional angiography. All lesions, the smallest 3 mm in diameter, were visible on spiral CT and MRA. The neck of the aneurysm and its anatomical relations could very accurately be determined in all cases. Advantages of spiral CT over MRA are: a short acquisition time with reduction of motion artefacts, no dependence on flow rate or cardiac output, and excellent visualisation of calcification, thrombus and bony landmarks. Disadvantages are the necessity for iodinated contrast medium, long postprocessing and reconstruction time and the possibility of overlap of bone and venous blood.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1432-1920
    Keywords: Aneurysm, intracranial ; Computed tomography, helical ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Spiral CT and magnetic resonance angiography (MRA) were performed in ten patients with 14 intracranial aneurysms known from conventional angiography. All lesions, the smallest 3 mm in diameter, were visible on spiral CT and MRA. The neck of the aneurysm and its anatomical relations could very accurately be determined in all cases. Advantages of spiral CT over MRA are: a short acquisition time with reduction of motion artefacts, no dependence on flow rate or cardiac output, and excellent visualisation of calcification, thrombus and bony landmarks. Disadvantages are the necessity for iodinated contrast medium, long postprocessing and reconstruction time and the possibility of overlap of bone and venous blood.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 7 (1997), S. S57 
    ISSN: 1432-1084
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...