Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (4)
Material
Years
Year
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A multicusp source for positive ion beams has been designed and constructed in collaboration with the Ion Beam Technology Department of LBNL for the TRIUMF ISAC project. This type of source has demonstrated a high yield of singly charged ions, a low energy spread, a good emittance, and is compact and simple. Several stages of tests and measurements using nonradioactive beams to characterize the source performance are being carried out both at LBNL and at TRIUMF prior to the final phase of radioactive target-source system tests. Results of these nonradioactive tests and certain problems encountered are reported and discussed in this article. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1314-1316 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A 15 mA dc H− multicusp source has been developed for injection into a TR30 cyclotron. This source is also used with a 900 kV tandem accelerator to obtain 10 mA protons at 1.8 MeV. The program is an extension of the 5–7 mA dc H− cusp source developed at TRIUMF during 1989–1990. Major efforts include the search for the optimal filament materials, shape, and location; comparison of cusp line confinement and magnetic filtering of electrons at the extraction region; optimization of extraction lense configuration; and upgrading of vacuum and power systems capability. The source is noncesiated and the maximum arc power available is only 5 kW. After the H− beams pass through an electron suppression grid and a 20 mm collimator, we obtained 15 mA with 0.66 π mm mrad 4 rms normalized emittance. At this output the e/H ratio was about 4. The best normalized emittance occurs around 5–7 mA, having a value of 0.37 π mm mrad. Further development in the near future is planned using cesium and multiple apertures in the hope of increasing dc H− currents to 30 mA while holding the normalized emittance below 0.75 π mm mrad. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have reported a 15 mA dc H− multicusp source at the sixth International Ion Source Conference in 1995 at Whistler. Since then, the H− beam has been further upgraded to 20 mA for 25 kV dc extraction. The D− beam output of the new cusp source has also been measured at 25 and 12.5 kV energies. An 8 mA D− peak current at 25 kV with 0.5 π mm mrad normalized 4 rms emittance has been obtained. Special attention was given to the effects of gas flow, pumping speed, and neutralization on the 12.5 kV operation which is used for the D− injection into a 15 MeV D− cyclotron. At present, we are making an effort to test the effect of injecting Cs in the vicinity of the plasma aperture. On the other hand, a hybrid of filament plus LaB6 cathode mechanism has been tested for filament lifetime issue. The results from these tests are reported. In particular, the experience in operating this new source for the Triumf/Nordion TR30 cyclotron is summarized. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A prototype surface ionization source coupled with a fixed-geometry extraction electrode system was commissioned on the Isotope Separator Accelerator (ISAC) ion source test stand at TRIUMF. The suitability of the ion source and extraction system for use in the ISAC facility was determined by a series of emittance measurements of the extracted beams. The test stand optics were successfully commissioned using the prototype ion source; emittance measurements of the mass-separated beams demonstrated that second- and third-order beam aberrations (introduced by the magnetic dipole mass separation) could be corrected by the use of multipole electrostatic optics elements. An upper limit of the root-mean-square-energy spread (2 eV) was deduced from the emittance measurements. Emittance measurements were performed at beam energies of 10–50 keV, as well as for ion masses ranging from Li+ to Rb+, to demonstrate the feasibility of the prototype for a variety of beam energies and masses. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...