  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have reported a 15 mA dc H− multicusp source at the sixth International Ion Source Conference in 1995 at Whistler. Since then, the H− beam has been further upgraded to 20 mA for 25 kV dc extraction. The D− beam output of the new cusp source has also been measured at 25 and 12.5 kV energies. An 8 mA D− peak current at 25 kV with 0.5 π mm mrad normalized 4 rms emittance has been obtained. Special attention was given to the effects of gas flow, pumping speed, and neutralization on the 12.5 kV operation which is used for the D− injection into a 15 MeV D− cyclotron. At present, we are making an effort to test the effect of injecting Cs in the vicinity of the plasma aperture. On the other hand, a hybrid of filament plus LaB6 cathode mechanism has been tested for filament lifetime issue. The results from these tests are reported. In particular, the experience in operating this new source for the Triumf/Nordion TR30 cyclotron is summarized. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1230-1232 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A cesium sputter, negative ion source was developed and built at Triumf. While designed for accelerator mass spectrometry, it can be applied in any field requiring intensive negative ion beams covering the whole range from hydrogen to uranium. The source features an internal cesium oven and simplified target insulation. A pneumatically actuated target changer contains a 28-sample wheel but allows manual placing of single samples as well. In initial runs the source produced over 1 μA of 40CaH−3 and .25 μA of 27Al− beams. The construction of the source and the operation of the sample changer are discussed in this article. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...