Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 357 (1997), S. 1020-1023 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract  The certification measurement for the cadmium concentration in the samples as performed by Isotope Dilution (ID) using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is described in framework of the International Measurement Evaluation Programme (IMEP). By using a primary method of measurement (ID), making up a full uncertainty budget and using a sensitive technique (ICP-MS), reference values traceable to SI can be obtained for this material. The uncertainty budget is performed in accordance with the ISO and EURACHEM guides on uncertainty. A comparison is made with certification results of other experienced laboratories also using primary methods where possible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The interface between silicon (100) and thermal silicon dioxide grown by wet, dry, and trichloroethylene oxidation has been investigated by scanning tunneling microscopy and scanning tunneling spectroscopy. The scanning tunneling microscopy images of the silicon surface, after removal of oxide, reveal the presence of silicon bumps (protrusions) in samples prepared by wet and dry oxidation while no protrusions are seen at the interface of trichloroethylene oxidized samples. The spectroscopic measurements predict that these are silicon protrusions and are produced by oxide growth conditions. X-ray photon spectroscopy on samples containing protrusions also supports the above prediction. Thus, our study suggests that roughness of the silicon–silicon dioxide interface depends on oxide growth conditions and a relatively smooth interface is obtained by tricholoroethylene oxidation. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Applied microbiology and biotechnology 51 (1999), S. 653-658 
    ISSN: 1432-0614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract A method that allows the rapid visualization of bacterial spatial colonization patterns on roots for the determination of general colonization trends was developed. This method, which analyzes images of roots, and bioluminescence-enhanced images of bacterial colonization patterns on these roots, was used to study the colonization patterns of seed-applied Enterobacter cloacae strain E6 on 3-day-old cucumber plants. Conventional dilution-plating methods indicated that E6 colonized cucumber tap roots in high populations and that these populations significantly decreased as the distance from the seed increased. In addition to confirming these observations, image analysis indicated that colonization by E6 significantly decreased on lateral roots as the distance increased horizontally away from the tap root, and that this bacterium did not evenly cover the most densely colonized regions of the cucumber root system. Results from these experiments indicate that the majority of E6 populations on cucumber roots after seed application are limited to the upper regions of the tap root and that E6 does not effectively colonize other regions of the root system.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0517
    Keywords: Key words Comparability ; Traceability ; Isotope-specific methods ; Isotope dilution mass spectrometry ; Neutron-activation analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract  In the seventh round of the Institute for Reference Materials and Measurements' International Measurement Evaluation Programme, 277 clinical laboratories from 17 countries participated. The measurands consisted of inorganic components, present at minor and trace level, in a human liquid serum. Results for calcium, chloride, copper, magnesium, sodium, selenium and zinc are reported and are compared to reference values established mainly by isotope dilution mass spectrometry and neutron-activation analysis. The overall conclusion is that routine measurements of total concentrations of the components by clinical laboratories are of high quality. The fraction of significant errors is small (0.5%) and the self-declared uncertainty values are generally fairly realistic. Results are further commented on with respect to the recent development in metrology in chemistry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 364 (1999), S. 437-439 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A simple method has been developed that allows a fast determination of the homogeneity of an element M in an alloy, even for minor components. This is done by measuring a ratio of ion currents I, I M/I M’O, whereby M’ is the matrix element, by inductively coupled plasma mass spectrometry (ICP-MS). The method can be used to determine the homogeneity of one component in a binary alloy and allows to estimate the sample size necessary to minimise uncertainty contributions due to inhomogeneity in the analysis of such an alloy. In this work the homogeneity of a niobium/0.1% zirconium alloy was determined on 1 mg samples. Accurate weighings of these small samples are not required, as the method is based on the measurement of the niobium/zirconium amount ratio in the dissolved samples. As this ratio is fairly large, the Zr/NbO amount ratio was measured instead to decrease the magnitude of the measured ratio. This ratio was found to be sufficiently stable over time for homogeneity testing. In this particular case the Zr/NbO ratio in the samples was found to vary by 0.049 relative for a 1 mg samples size.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 361 (1998), S. 767-773 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Re-certification of the absolute isotopic composition of the natural lithium isotopic reference material (IRM), IRMM-016, requires measurements calibrated by means of synthetic mixtures of highly enriched lithium isotopes. Ten such mixtures were prepared by weighing and mixing of two well characterised, isotopically enriched, Li2CO3 compounds. The starting materials, 99.9981% enriched 6Li, and 99.9937% enriched 7Li, were purified by ion exchange, and the purified materials converted from LiOH to Li2CO3 by reaction with CO2. Ten new mixtures were prepared by mixing different weighed amounts of these dissolved Li2CO3 carrier compounds. The compounds had an estimated level of impurities of 100 ± 100 μg · g–1 (expanded uncertainty with a coverage factor of 2). In the ten mixtures, the n(6Li)/n(7Li) ratio varies from 0.025 to 14 and the achieved expanded relative uncertainty on the amount ratio prepared is typically 2 · 10–4. These mixtures were then used to determine the correction factor, K, for mass discrimination of the measurement procedure and instrument concerned.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 361 (1998), S. 227-234 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract One of the routes to re-determine the Avogadro constant requires ultra-high accuracy isotopic measurements of amount ratios of Si isotopes to 10–5 reproducibilities on the ratio measurements and calibrating the results by synthetic isotope mixtures prepared to 2 · 10–5 relative combined uncertainty. The route to these results is described, followed by a description of the improvement of our knowledge of the Avogadro constant N A through these measurements. The same route has recently been opened for other gases and has opened the way to the establishment of “Primary Standards of Measurements” for gas isotopic measurements. It is described how these highly accurate measurements of ratios of amount of substance have considerably contributed to clearer thinking about concepts for measurements of amount of substance. The acquired expertise in measurement instrumentation and measurement procedures can now be extended to a more general use in measurements of isotope amount ratio (i.e. in other elements). It can also be combined with isotope dilution. This latter combination opens up a new route towards a realization of traceability of an amount-of-substance measurement to the SI and to the (measurement procedure and instrumentation leading to) Avogadro constant.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1106
    Keywords: Key words Vestibular ; Deafferentation ; Vestibular compensation ; Horizontal vestibulo-ocular reflex ; Impulse ; Guinea pig
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  While there is agreement that unilateral vestibular deafferentation (UVD) invariably produces an immediate severe horizontal vestibulo-ocular reflex (HVOR) deficit, there is disagreement about whether or not this deficit recovers and, if so, whether it recovers fully or only partly. We suspected that this disagreement might mainly be due to experimental factors, such as the species studied, the means chosen to carry out the UVD, or the nature of the test stimulus used. Our aim was to sort out some of these factors. To do this, we studied the HVOR of alert guinea pigs in response to low and high acceleration sinusoidal and high acceleration impulses after UVD by either labyrinthectomy or by vestibular neurectomy. The HVOR in response to high acceleration impulsive yaw rotations was measured before, and at various times after, either unilateral labyrinthectomy or superior vestibular neurectomy. Following UVD, there was a severe impairment of the HVOR for ipsilesional rotations and a slight impairment for contralesional rotations, after either operation. This asymmetrical HVOR deficit in the guinea pig parallels the deficit observed in humans. Between the first measurement, which was made 1 week after UVD, and the last, which was made 3 months after UVD, there was no change in the HVOR. This lack of recovery was the same after labyrinthectomy as after vestibular neurectomy. The HVOR to low and high acceleration sinusoidal yaw rotations were measured after UVD, and the results were compared with those in response to impulsive rotations. For low acceleration sinusoidal rotations (250°/s2), the gain was symmetrical, although reduced bilaterally. As the peak head acceleration increased, the HVOR became increasingly asymmetric. The HVOR asymmetry for sinusoidal rotations was significantly less than for impulsive rotations that had the same high peak head acceleration (2500°/s2). Our results show that the HVOR deficit after UVD is the same in guinea pigs as in humans; that it is the same after vestibular neurectomy as after labyrinthectomy; that it is lasting and severe in response to high acceleration rotations; and, that it is more obvious in response to impulses than to sinusoids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-1920
    Keywords: Radiation dermatitis Embolization ; Arteriovenous malformation, spinal
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Few cases of radiation injury related to lengthy interventional neuroradiologic procedures have been reported, although concern has been heightened, as evidenced by a 1994 FDA Public Health Advisory. We report a case of radiation-induced dermatitis in a patient undergoing multiple diagnostic and embolization procedures for treatment of a spinal arteriovenous malformation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-5225
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Summary Radiata pine veneers and blocks were exposed to natural weathering under Australian summer conditions over a period of 30 days. Infrared spectroscopy revealed that there was perceptible surface delignification after 4 hours exposure, substantial surface delignification after 3 days exposure and almost complete surface delignification after 6 days. Rapid lignin degradation was also suggested by measurements of the acid insoluble lignin content of weathered veneers. Viscometry determinations on holocellulose samples from weathered veneers and unweathered controls indicated significant depolymerisation of cellulose after 4 days exposure. A tape test was used to assess the adhesion of acrylic latex primers to weathered blocks. The adhesion of exterior acrylic primers decreased on weathered wood surfaces and was significantly lower on specimens that were weathered for 5 to 10 days. An oil-modified acrylic primer showed greater adhesion to weathered wood surfaces. Primer adhesion was lower on weathered radial surfaces than on similarly exposed tangential surfaces. The practical implications of these findings for the coating of exterior wood with acrylic latex primers are discussed briefly.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...