Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994
  • 1985-1989  (2)
  • 1965-1969
  • Implantable miniature sensor  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 24 (1986), S. 235-242 
    ISSN: 1741-0444
    Keywords: Blood flow ; Cardiac output ; Implantable miniature sensor ; Left ventricular assist device ; Stroke volume ; Transit-time technique ; Ultrasonic Doppler flowmetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An ultrasonic flowmeter incorporated with implantable miniature sensors was developed. Two sets of miniature ultrasonic sensors are attached to the surface of a blood vessel. The outer diameter of the vessel and the blood velocity are measured simultaneously by means of the ultrasonic transit-time technique and the ultrasonic Doppler method, respectively. Instantaneous blood flow is calculated by multiplying the flow velocity by the cross-sectional area calculated from the diameter Stroke volume and cardiac output can also be obtained, when the system is applied to the ascending aorta. After preliminary benchtop tests, acutein vivo studies were carried out to evaluate the accuracy and performance of the system. The blood flow in the descending aortas of dogs and a goat were measured simultaneously by the ultrasonic system and an electromagnetic flowmeter. The correlation coefficient between the data obtained by the two methods was 0·968. The system was applied to measure the blood flow in the ascending aortas of goats which had had heart failures induced and were implanted with left ventricular assist devices.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 25 (1987), S. 355-358 
    ISSN: 1741-0444
    Keywords: Eight-channel operation ; Implantable miniature sensor ; Transit time ; Ultrasonic displacement meter
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...