Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (10)
  • 1985-1989  (2)
  • 1955-1959
  • Polymer and Materials Science  (10)
  • PEEP  (2)
Material
Years
  • 1990-1994  (10)
  • 1985-1989  (2)
  • 1955-1959
  • 1995-1999  (19)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 13 (1987), S. 315-322 
    ISSN: 1432-1238
    Keywords: PEEP ; Lung stretch ; Respiratory drive ; Carbon dioxide ; Piglets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The effect of ventilatory frequency of high-frequency jet ventilation (HFJV) from 1 to 5 Hz, apart from changes in thoracic volume, on spontaneous breathing activity was studied in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established either by changing minute volume of ventilation or by adding CO2 to the respiratory gas. The higher the apnea point, the higher the suppression of spontaneous breathing activity was assumed to be. If the apnea point was searched for by changing minute volume a progressive increase of suppression of spontaneous respiratory activity was found at ventilatory rates of 3 Hz or more, concomitantly with a rise in end-expiratory pressure (PEE). In case the tidal volume was kept constant, increase of ventilatory rate resulted in a tremendous increase of lung volume, together with considerably higher levels of PEE. When under these conditions the apnea point was searched for by adding CO2 to the respiratory gas a much higher CO2-drive was needed for spontaneous breathing and therefore a much stronger inhibition of spontaneous breathing was concluded. By placing the animals in a body box in which pressure could be varied, thoracic volume could be kept constant during HFJV. When thoracic volume was kept constant in this way a constant tidal volume at increasing jet frequencies resulted in only a slight increase in suppression of spontaneous breathing. We conclude that the increase in lung volume is a major factor in suppressing central respiratory activity during HFJV. Jet frequency by itself might be an additional suppressive factor. Airway CO2 did not seem to have an important effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 12 (1986), S. 26-32 
    ISSN: 1432-1238
    Keywords: Ventilatory pattern ; PEEP ; Lung volume ; Respiratory drive ; EMG diaphragm ; Piglets
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Conditions which suppress spontaneous breathing activity during high-frequency jet ventilation (HFJV) were analysed in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established during different patterns of ventilation, either by changing the minute volume or by adding CO2 to the inspiratory gas. Arterial oxygen tension was maintained throughout the study above 80 mm Hg. An elevation of ventilatory rate increased the apnea point, suggesting a progressive suppression of spontaneous breathing. This suppression did not depend on the amount of lung stretch during insufflation, because at higher rates lower tidal volumes were used. Suppression also appeared to be independent of insufflatory flow, i.e. the velocity of lung stretch. At higher frequencies end-expiratory airway pressure (PEE) increased and there appeared to be a positive relationship between the apnea point and PEE. In a separate series this positive relationship between the apnea point and PEE was confirmed. A hysteresis effect in this relationship, however, suggests that other than jet frequency, lung volume rather than positive end-expiratory pressure (PEEP) is a major determinant of suppression of spontaneous breathing activity during HFJV.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 4 (1993), S. 213-219 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness. © 1993 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 66 (1994), S. 1229-1230 
    ISSN: 0009-286X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed ceramic coatings of fluorapatite (FA), magnesiumwhitlockite (MW), and hydroxylapatite (HA), and noncoated Ti-6Al-4V alloy (Ti) implants were evaluated histologically and histomorphometrically in a goat animal study. Cylindrical Ti-6Al-4V plugs were plasma-spray-coated with FA, MW, and HA. Noncoated, gritblasted Ti plugs served as controls. The plugs were implanted into the right femur and left humerus of 20 adults goats. The results were evaluated using descriptive histology and histomorphometry. The histomorphometry consisted of measurements of bone apposition and coating thickness. The results demonstrated that FA showed a high amount of bone apposition without signs of degradation or dissolution. MW showed considerable reduction in thickness and at 12 weeks an adverse tissue reaction. However, at 25 weeks the amount of bone apposition was significantly increased compared with the 12-week implants. HA revealed considerable and progressive reduction in thickness and at 25 weeks a lower amount of bone apposition than FA and MW. At 12 weeks the Ti implants did reveal bone apposition, although frequently localized fibrous tissue was visible. At 25 weeks the Ti implants did not differ in bone apposition from the HA implants. Further studies are necessary on the effect of degradation or dissolution of HA on the compatibility with bone. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1047-1054 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on the soft-tissue response to titanium fiber mesh percutaneous implants. The implants were inserted in the backs of 15 rabbits. The surgical procedure was performed in two steps: implantation of the subcutaneous part of the implants and, after 3 months, fixation of the percutaneous part into the subcutaneous part. Two and 6 months after insertion the animals were sacrificed and the implants, with their surrounding tissues, were processed histologically. Light microscopic analysis demonstrated that only one implant showed considerable skin retraction in the percutaneous area. Around the rest of the implants no downgrowth or only a very limited epidermal downgrowth was observed. Furthermore, the fiber mesh material showed good biocompatible behavior. These results confirm the previous finding that sintered titanium fiberweb structures are effective for the stabilization of percutaneous devices located in soft tissues and can improve their performance. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 973-989 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to obtain more information about the bone reaction to titanium and hydroxypatite (HA)-coated titanium implants during the first 3 months after implantation. Therefore, uncoated and coated implants were inserted into the tibia of rabbits for various implantation periods. The histological results demonstrated that although there were no marked differences in bony reaction at the cortical level to the different implant materials, HA-coating appeared to induce more bone formation in the medullary cavity. It was also noted, that 3 months after insertion loss of coating thickness had occurred.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 27 (1993), S. 603-610 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The aim of this study was to investigate bone response to and biostability of three different hydroxyapatite (HA)-coatings. Therefore, coated and uncoated titanium implants were inserted into the tibia of rabbits. Implantation times were at 3 and 12 weeks. The histological evaluation included measurement of the amount of bone apposition to the various implant surfaces. The results demonstrated at 3 and 12 weeks no marked differences in bony reaction at the cortical level to the different implant materials. However, compared with the 3-week specimens, at 12 weeks extensive maturation of the woven bone callus had occurred. In addition, all 12-week implants induced bone formation in the medullary cavity. It was also noted that all HA-coatings showed loss of coating thickness. Quantitative determination of bone contact demonstrated that all 12-week implants showed the same high amount of bone apposition. © 1993 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 1477-1484 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed hydroxylapatite coatings on metals such as titanium have been investigated for many years and have shown a good biocompatibility when implanted in bony tissues. Radiofrequency magnetron sputtering was used as an alternative method to deposit thin films of hydroxylapatite on titanium substrates. X-ray diffraction demonstrated that the sputtered layer was crystalline with a preferred (001) crystallographic orientation with the C-axis perpendicular to the substrate surface. Scanning electron microscopy showed that the deposited films had a uniform and dense structure. The calcium phosphate ratio varied between 1.5 and 2.0, as determined by energy-dispersive X-ray analysis. The in vitro dissolution appeared to be determined by the degree of the coating's crystallinity. © 1994 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 295-307 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study reports on certain aspects of wound-healing around percutaneous implants. Plasma-sprayed and dense hydroxylapatite, titanium, and carbon test implants were inserted into the tibia and the cranium of 12 rabbits. Four and 8 months after insertion, the animals were sacrificed and the implants with their surrounding tissues were processed histologically. Light- and transmission electron microscopic investigations were performed. It is found that direct and indirect boneanchoring favors the longevity of percutaneous implants. No differences in tissue reaction between the various implant materials were observed.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...