Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (3)
  • 42.55.Bq  (1)
  • 43.20.Ye  (1)
  • Cyclic variation in integrated backscatter  (1)
  • 1
    ISSN: 1432-0649
    Keywords: 43.25.Ud ; 43.20.Ye
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The dependence of photoacoustic spectra on different experimental parameters was investigated by both theoretical and experimental means. The experiments were carried out with an inexpensive resonant optoacoustic system based on near-infrared laser diodes, which allowed photoacoustic and direct absorption spectra to be recorded simultaneously. The experimental observations were compared to theoretical predictions. It was also demonstrated that source-frequency (wavelength) modulation at the resonance frequency of the cell provides superior signal to noise ratio compared to amplitude modulation and eliminates background drifts and fluctuations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 40 (1992), S. 163-167 
    ISSN: 1741-0444
    Keywords: Cardiac ischaemia ; Cyclic variation in integrated backscatter ; Fusion image ; Integrated backscatter ; Myocardium ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Quantitative ultrasonic tissue characterisation of the myocardium based on integrated backscatter (IB) has the potential of becoming an effective method for detecting and evaluating myocardial ischaemia. To facilitate IB-based clinical applications, a new imaging method has been developed that combines the anatomical information of a B-mode image with the contractile performance of a selected myocardial region. To produce such a fusion image, a region of interest (ROI) in a B-mode cardiac image was first selected by the user. Algorithms for detection of the endocardium andepicardium were developed, and the resulting mean distance between the computer-detected curve and the manually traced curve was 0.83 mm for the endocardium and 0.58 mm for the epicardium. The cyclic variation of IB (CVIB) of each myocardial tissue element within the ROI was then calculated over one cardiac cycle. Finally, a grey-scale B-mode image at the end of diastole was displayed as a still image, and the pixels representing the myocardial tissue in the ROI colour-coded according to the corresponding CVIB over the past heart cycle. Both the B-mode image and the colour-coded region were refreshed (up-dated) at the next end-of-diastole. Preliminary results from normal (CVIB=10–12dB) and ischaemic (CVIB=5–7 dB) canine hearts are presented that demonstrate the utility of this new imaging method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-6079
    Keywords: 42.55.Bi ; 42.55.Bq ; 42.60.Fc
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We develop an experimental process to measure the dynamical parameters for a single mode CO2 laser which is independent from usual empirical estimation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...